Nissan Silvia. Manual — part 154
7
CHECK COOLING FAN MOTOR
Refer to “Component Inspection”, EC-136.
OK or NG
OK
©
GO TO 8.
NG
©
Replace cooling fan motor.
8
CHECK INTERMITTENT INCIDENT
Perform “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-82.
©
INSPECTION END
GI
MA
EM
LC
FE
CL
MT
AT
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC 0208 OVERHEAT (COOLING SYSTEM)
Diagnostic Procedure (Cont’d)
EC-131
PROCEDURE B
=NMEC0702S02
1
CHECK COOLING FAN POWER SUPPLY CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect cooling fan relay-2.
SEC381C
3. Turn ignition switch “ON”.
4. Check voltage between cooling fan relays-2 terminals 2, 5 and ground with CONSULT-II or tester.
SEC412C
OK or NG
OK
©
GO TO 3.
NG
©
GO TO 2.
2
DETECT MALFUNCTIONING PART
Check the following.
I
10A fuse
I
40A fusible link
I
Harness for open or short between cooling fan relay-2 and fuse
I
Harness for open or short between cooling fan relay-2 and fusible link
©
Repair open circuit or short to ground or short to power in harness or connectors.
DTC 0208 OVERHEAT (COOLING SYSTEM)
Diagnostic Procedure (Cont’d)
EC-132
3
CHECK COOLING FAN MOTOR CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect cooling fan motor harness connector.
SEC382C
3. Check harness continuity between cooling fan relay-2 terminal 3 and cooling fan motor terminal 4, cooling fan motor
terminal 2 and body ground.
Refer to Wiring Diagram.
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 4.
NG
©
Repair open circuit or short to ground or short to power in harness or connectors.
4
CHECK COOLING FAN OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 10 and cooling fan relay-2 terminal 1.
Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 6.
NG
©
GO TO 5.
5
DETECT MALFUNCTIONING PART
Check the following.
I
Harness connectors F4, M60
I
Harness connectors M10, E101
I
Harness for open or short between cooling fan relay-2 and ECM
©
Repair open circuit or short to ground or short to power in harness or connectors.
6
CHECK COOLING FAN RELAY-2
Refer to “Component Inspection”, EC-135.
OK or NG
OK
©
GO TO 7.
NG
©
Replace cooling fan relay-2.
GI
MA
EM
LC
FE
CL
MT
AT
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC 0208 OVERHEAT (COOLING SYSTEM)
Diagnostic Procedure (Cont’d)
EC-133
7
CHECK COOLING FAN MOTOR
Refer to “Component Inspection”, EC-136.
OK or NG
OK
©
GO TO 8.
NG
©
Replace cooling fan motors.
8
CHECK INTERMITTENT INCIDENT
Perform “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-82.
©
INSPECTION END
DTC 0208 OVERHEAT (COOLING SYSTEM)
Diagnostic Procedure (Cont’d)
EC-134