Qashqai J11. Exterior Lighting system — part 16
EXL-242
< BASIC INSPECTION >
[HALOGEN HEADLAMP]
DIAGNOSIS AND REPAIR WORK FLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow
INFOID:0000000010469917
OVERALL SEQUENCE
DETAILED FLOW
JMKIA8652GB
DIAGNOSIS AND REPAIR WORK FLOW
EXL-243
< BASIC INSPECTION >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
1.
GET INFORMATION FOR SYMPTOM
1.
Get detailed information from the customer about the symptom (the condition and the environment when
the incident/malfunction occurs).
2.
Check operation condition of the function that is malfunctioning.
>> GO TO 2.
2.
CHECK DTC
1.
Check DTC.
2.
Perform the following procedure if DTC is detected.
-
Record DTC and freeze frame data (Print them out using CONSULT.)
-
Erase DTC.
-
Study the relationship between the cause detected by DTC and the symptom described by the customer.
3.
Check related service bulletins for information.
Are any symptoms described and any DTC detected?
Symptom is described, DTC is detected>>GO TO 3.
Symptom is described, DTC is not detected>>GO TO 4.
Symptom is not described, DTC is detected>>GO TO 5.
3.
CONFIRM THE SYMPTOM
Try to confirm the symptom described by the customer.
Also study the normal operation and fail-safe related to the symptom.
Verify relation between the symptom and the condition when the symptom is detected.
>> GO TO 5.
4.
CONFIRM THE SYMPTOM
Try to confirm the symptom described by the customer.
Verify relation between the symptom and the condition when the symptom is detected.
>> GO TO 6.
5.
PERFORM DTC CONFIRMATION PROCEDURE
Perform DTC CONFIRMATION PROCEDURE for the detected DTC, and then check that DTC is detected
again. At this time, always connect CONSULT to the vehicle, and check self diagnostic results in real time.
If two or more DTCs are detected, refer to DTC INSPECTION PRIORITY CHART, and determine trouble diag-
nosis order.
NOTE:
• Freeze frame data is useful if the DTC is not detected.
• Perform Component Function Check if DTC CONFIRMATION PROCEDURE is not included on Service
Manual. This simplified check procedure is an effective alternative though DTC cannot be detected during
this check.
If the result of Component Function Check is NG, it is the same as the detection of DTC by DTC CONFIR-
MATION PROCEDURE.
Is DTC detected?
YES
>> GO TO 7.
NO
>> Check according to
GI-41, "Intermittent Incident"
.
6.
DETECT MALFUNCTIONING SYSTEM BY SYMPTOM DIAGNOSIS
Detect malfunctioning system according to SYMPTOM DIAGNOSIS based on the confirmed symptom in step
4, and determine the trouble diagnosis order based on possible causes and symptom.
Is the symptom described?
YES
>> GO TO 7.
NO
>> Monitor input data from related sensors or check voltage of related module terminals using CON-
SULT.
7.
DETECT MALFUNCTIONING PART BY DIAGNOSIS PROCEDURE
EXL-244
< BASIC INSPECTION >
[HALOGEN HEADLAMP]
DIAGNOSIS AND REPAIR WORK FLOW
Inspect according to Diagnosis Procedure of the system.
Is malfunctioning part detected?
YES
>> GO TO 8.
NO
>> Check according to
GI-41, "Intermittent Incident"
.
8.
REPAIR OR REPLACE THE MALFUNCTIONING PART
1.
Repair or replace the malfunctioning part.
2.
Reconnect parts or connectors disconnected during Diagnosis Procedure again after repair and replace-
ment.
3.
Check DTC. If DTC is detected, erase it.
>> GO TO 9.
9.
FINAL CHECK
When DTC is detected in step 2, perform DTC CONFIRMATION PROCEDURE again, and then check that the
malfunction is repaired securely.
When symptom is described by the customer, refer to confirmed symptom in step 3 or 4, and check that the
symptom is not detected.
Is DTC detected and does symptom remain?
YES-1 >> DTC is detected: GO TO 7.
YES-2 >> Symptom remains: GO TO 4.
NO
>> Before returning the vehicle to the customer, always erase DTC.
B121A FRONT FOG LAMP LH POWER SUPPLY CIRCUIT
EXL-245
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
DTC/CIRCUIT DIAGNOSIS
B121A FRONT FOG LAMP LH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469921
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front fog lamp LH bulb
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the front fog lamp LH power supply circuit until the front fog lamp ON conditions
are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “F FOG LH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the front fog lamp LH power supply circuit, and damage
accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not turn ON
the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Turn ignition switch ON.
3.
Turn lighting switch 1ST, and front fog lamp switch ON.
4.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
5.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-245, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469922
1.
CHECK FRONT FOG LAMP LH POWER SUPPLY CIRCUIT (SHORT)
1.
Turn ignition switch OFF.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B121A
FR FOG LAMP LH PWR SPLY CIRC
(Front fog lamp left hand power supply cir-
cuit)
[CIRC
SHORT TO
GRND]
When front fog lamp ON conditions are satisfied (smart
FET inside IPDM E/R is ON), and overcurrent is detected
in the front fog lamp LH power supply circuit.
Monitor item
Monitor status
F FOG LH CIRC MALFUNCTN
0
1
EXL-246
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B121A FRONT FOG LAMP LH POWER SUPPLY CIRCUIT
2.
Turn lighting switch OFF, and front fog lamp switch OFF.
3.
Disconnect IPDM E/R connector and front fog lamp LH connector.
4.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK FRONT FOG LAMP LH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “FRONT FOG LAMP” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front fog lamp LH harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
3.
CHECK FRONT FOG LAMP LH BULB
Check the front fog lamp LH bulb. Refer to
EXL-246, "Component Inspection"
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front fog lamp LH bulb. Refer to
.
Component Inspection
INFOID:0000000010469923
1.
CHECK FRONT FOG LAMP LH BULB
1.
Turn ignition switch OFF.
2.
Disconnect front fog lamp LH connector.
3.
Check resistance of front fog lamp LH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front fog lamp LH bulb. Refer to
.
IPDM E/R
—
Continuity
Connector
Terminal
E102
59
Ground
Not existed
+
-
Test item
Voltage
Front fog lamp LH
Connector
Terminal
E94
1
Ground
FRONT FOG
LAMP
On
9 – 16 V
Off
0 – 1 V
Front fog lamp LH
Resistance
Terminal
1
2
Except 0
Ω
B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT
EXL-247
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469924
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front combination lamp RH internal circuit
- LED (Daytime running light)
- Control circuit
- Harness
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the daytime running light RH power supply circuit until the daytime running light
ON conditions are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “DTRL RH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the daytime running light RH power supply circuit, and
damage accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not
turn ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
PCS-67, "Removal and Installation"
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Start engine.
3.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
4.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-247, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469925
1.
CHECK DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT (SHORT)
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B1231
DTRL RH PWR SPLY CIRC
(Daytime running light right hand power
supply circuit)
[CIRC
SHORT TO
GRND]
When daytime running light ON conditions are satisfied
(smart FET inside IPDM E/R is ON), and overcurrent is
detected in the daytime running light RH power supply cir-
cuit.
Monitor item
Monitor status
DTRL RH CIRC MALFUNCTN
0
1
EXL-248
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B1231 DAYTIME RUNNING LIGHT RH POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect IPDM E/R connector and front combination lamp RH connector.
3.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK DAYTIME RUNNING LIGHT RH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “DAYTIME RUNNING LIGHT” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp RH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
3.
CHECK DAYTIME RUNNING LIGHT RH
Check the daytime running light RH. Refer to
EXL-248, "Component Inspection"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp RH. Refer to
EXL-318, "Removal and Installation"
Component Inspection
INFOID:0000000010469926
1.
CHECK DAYTIME RUNNING LIGHT RH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp RH connector.
3.
Check resistance of front combination lamp RH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp RH. Refer to
EXL-318, "Removal and Installation"
IPDM E/R
—
Continuity
Connector
Terminal
E101
50
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp RH
Connector
Terminal
E92
2
Ground
DAYTIME
RUNNING
LIGHT
On
9 – 16 V
Off
0 – 1 V
Front combination lamp RH
Resistance
Terminal
2
1
Except 0
Ω
B1256 FRONT FOG LAMP RH POWER SUPPLY CIRCUIT
EXL-249
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B1256 FRONT FOG LAMP RH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469927
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front fog lamp RH bulb
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the front fog lamp RH power supply circuit until the front fog lamp ON conditions
are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “F FOG RH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the front fog lamp RH power supply circuit, and dam-
age accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not turn
ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
67, "Removal and Installation"
.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Turn ignition switch ON.
3.
Turn lighting switch 1ST, and front fog lamp switch ON.
4.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
5.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-249, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469928
1.
CHECK FRONT FOG LAMP RH POWER SUPPLY CIRCUIT (SHORT)
1.
Turn ignition switch OFF.
2.
Turn lighting switch OFF, and front fog lamp switch OFF.
3.
Disconnect IPDM E/R connector and front fog lamp RH connector.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B1256
FR FOG LAMP RH PWR SPLY CIRC
(Front fog lamp right hand power supply cir-
cuit)
[CIRC
SHORT TO
GRND]
When front fog lamp ON conditions are satisfied (smart
FET inside IPDM E/R is ON), and overcurrent is detected
in the front fog lamp RH power supply circuit.
Monitor item
Monitor status
F FOG RH CIRC MALFUNCTN
0
1
EXL-250
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B1256 FRONT FOG LAMP RH POWER SUPPLY CIRCUIT
4.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK FRONT FOG LAMP RH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “FRONT FOG LAMP” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front fog lamp RH harness connector and
ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
3.
CHECK FRONT FOG LAMP RH BULB
Check the front fog lamp RH bulb. Refer to
EXL-250, "Component Inspection"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front fog lamp RH bulb. Refer to
Component Inspection
INFOID:0000000010469929
1.
CHECK FRONT FOG LAMP RH BULB
1.
Turn ignition switch OFF.
2.
Disconnect front fog lamp RH connector.
3.
Check resistance of front fog lamp RH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front fog lamp RH bulb. Refer to
IPDM E/R
—
Continuity
Connector
Terminal
E101
49
Ground
Not existed
+
-
Test item
Voltage
Front fog lamp RH
Connector
Terminal
E95
1
Ground
FRONT FOG
LAMP
On
9 – 16 V
Off
0 – 1 V
Front fog lamp RH
Resistance
Terminal
1
2
Except 0
Ω
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
EXL-251
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469938
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Front combination lamp LH internal circuit
- LED (Daytime running light)
- Control circuit
- Harness
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the daytime running light LH power supply circuit until the daytime running light
ON conditions are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “DTRL LH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the daytime running light LH power supply circuit, and
damage accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not
turn ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
PCS-67, "Removal and Installation"
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Start engine.
3.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
4.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-251, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469939
1.
CHECK DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT (SHORT)
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B20CB
DTRL LH PWR SPLY CIRC
(Daytime running light left hand power sup-
ply circuit)
[CIRC
SHORT TO
GRND]
When daytime running light ON conditions are satisfied
(smart FET inside IPDM E/R is ON), and overcurrent is
detected in the daytime running light LH power supply cir-
cuit.
Monitor item
Monitor status
DTRL LH CIRC MALFUNCTN
0
1
EXL-252
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B20CB DAYTIME RUNNING LIGHT LH POWER SUPPLY CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect IPDM E/R connector and front combination lamp LH connector.
3.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK DAYTIME RUNNING LIGHT LH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “DAYTIME RUNNING LIGHT” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp LH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
3.
CHECK DAYTIME RUNNING LIGHT LH
Check the daytime running light LH. Refer to
EXL-252, "Component Inspection"
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-318, "Removal and Installation"
.
Component Inspection
INFOID:0000000010469940
1.
CHECK DAYTIME RUNNING LIGHT LH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp LH connector.
3.
Check resistance of front combination lamp LH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front combination lamp LH. Refer to
EXL-318, "Removal and Installation"
.
IPDM E/R
—
Continuity
Connector
Terminal
E102
64
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp LH
Connector
Terminal
E90
2
Ground
DAYTIME
RUNNING
LIGHT
On
9 – 16 V
Off
0 – 1 V
Front combination lamp LH
Resistance
Terminal
2
1
Except 0
Ω
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
EXL-253
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469941
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Headlamp (HI) LH bulb
• Headlamp (HI) LH bulb socket
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the headlamp (HI) LH power supply circuit until the headlamp (HI) ON conditions
are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “HL (HI) LH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the headlamp (HI) LH power supply circuit, and dam-
age accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not turn
ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
67, "Removal and Installation"
.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Turn ignition switch ON.
3.
Turn lighting switch 2ND, and lighting switch HI.
4.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
5.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-253, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469942
1.
CHECK HEADLAMP (HI) LH POWER SUPPLY CIRCUIT (SHORT)
1.
Turn ignition switch OFF.
2.
Turn lighting switch OFF.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B20CE
HL (HI) LH PWR SPLY CIRC
[Headlamp (high) left hand power supply
circuit]
[CIRC
SHORT TO
GRND]
When headlamp (HI) ON conditions are satisfied (smart
FET inside IPDM E/R is ON), and overcurrent is detected
in the headlamp (HI) LH power supply circuit.
Monitor item
Monitor status
HL (HI) LH CIRC MALFUNCTN
0
1
EXL-254
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
3.
Disconnect IPDM E/R connector and front combination lamp LH connector.
4.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK HEADLAMP (HI) LH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “HEADLAMP (HI)” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp LH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
3.
CHECK HEADLAMP (HI) LH
Check the headlamp (HI) LH. Refer to
EXL-254, "Component Inspection"
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Repair or replace the malfunctioning part.
Component Inspection
INFOID:0000000010469943
1.
CHECK HEADLAMP (HI) LH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp LH connector.
3.
Check resistance of front combination lamp LH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK HEADLAMP (HI) LH
1.
Remove headlamp (HI) LH bulb.
2.
Check resistance of front combination lamp LH terminals.
IPDM E/R
—
Continuity
Connector
Terminal
E101
51
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp LH
Connector
Terminal
E90
5
Ground
HEADLAMP
(HI)
On
9 – 16 V
Off
0 – 1 V
Front combination lamp LH
Resistance
Terminal
5
1
Except 0
Ω
B20CE HEADLAMP (HI) LH POWER SUPPLY CIRCUIT
EXL-255
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
Is the inspection result normal?
YES
>> Replace headlamp (HI) LH bulb. Refer to
.
NO
>> Repair or replace the headlamp (HI) LH bulb socket.
Front combination lamp LH
Resistance
Terminal
5
1
Except 0
Ω
EXL-256
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
B20CF HEADLAMP (HI) RH POWER SUPPLY CIRCUIT
B20CF HEADLAMP (HI) RH POWER SUPPLY CIRCUIT
DTC Description
INFOID:0000000010469944
DTC DETECTION LOGIC
POSSIBLE CAUSE
• Harness or connector
• Headlamp (HI) RH bulb
• Headlamp (HI) RH bulb socket
• IPDM E/R
FAIL-SAFE
Shuts off the power supply to the headlamp (HI) RH power supply circuit until the headlamp (HI) ON conditions
are no longer satisfied.
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
With CONSULT
1.
Turn ignition switch ON.
2.
Select “HL (HI) RH CIRC MALFUNCTN” in “Data Monitor” mode of “IPDM E/R” using CONSULT.
3.
Check the monitor status.
What is the monitor status?
“0”
>> GO TO 2.
“1”
>> A short circuit is detected multiple times in the headlamp (HI) RH power supply circuit, and dam-
age accumulates at the smart FET inside the IPDM E/R. For this reason, IPDM E/R does not turn
ON the smart FET. Because the DTC cannot be reproduced in this state, perform
and replace IPDM E/R after the malfunctioning part is repaired. Refer to
67, "Removal and Installation"
.
2.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
1.
Turn ignition switch OFF.
2.
Turn ignition switch ON.
3.
Turn lighting switch 2ND, and lighting switch HI.
4.
Select “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
5.
Check DTC.
Is DTC detected?
YES
>> Refer to
EXL-256, "Diagnosis Procedure"
.
NO-1
>> To check malfunction symptom before repair: Refer to
GI-41, "Intermittent Incident"
.
NO-2
>> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010469945
1.
CHECK HEADLAMP (HI) RH POWER SUPPLY CIRCUIT (SHORT)
1.
Turn ignition switch OFF.
2.
Turn lighting switch OFF.
DTC No.
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
B20CF
HL (HI) RH PWR SPLY CIRC
[Headlamp (high) left hand power supply
circuit]
[CIRC
SHORT TO
GRND]
When headlamp (HI) ON conditions are satisfied (smart
FET inside IPDM E/R is ON), and overcurrent is detected
in the headlamp (HI) RH power supply circuit.
Monitor item
Monitor status
HL (HI) RH CIRC MALFUNCTN
0
1
B20CF HEADLAMP (HI) RH POWER SUPPLY CIRCUIT
EXL-257
< DTC/CIRCUIT DIAGNOSIS >
[HALOGEN HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
3.
Disconnect IPDM E/R connector and front combination lamp RH connector.
4.
Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness.
2.
CHECK HEADLAMP (HI) RH POWER SUPPLY
With CONSULT
1.
Connect IPDM E/R connector.
2.
Turn ignition switch ON
3.
Select “HEADLAMP (HI)” in “Active Test” mode of “IPDM E/R” using CONSULT.
4.
With operating the test items, check the voltage between front combination lamp RH harness connector
and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace IPDM E/R. Refer to
PCS-67, "Removal and Installation"
.
3.
CHECK HEADLAMP (HI) RH
Check the headlamp (HI) RH. Refer to
EXL-257, "Component Inspection"
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Repair or replace the malfunctioning part.
Component Inspection
INFOID:0000000010469946
1.
CHECK HEADLAMP (HI) RH
1.
Turn ignition switch OFF.
2.
Disconnect front combination lamp RH connector.
3.
Check resistance of front combination lamp RH terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK HEADLAMP (HI) RH
1.
Remove headlamp (HI) RH bulb.
2.
Check resistance of front combination lamp RH terminals.
IPDM E/R
—
Continuity
Connector
Terminal
E102
62
Ground
Not existed
+
-
Test item
Voltage
Front combination lamp RH
Connector
Terminal
E92
5
Ground
HEADLAMP
(HI)
On
9 – 16 V
Off
0 – 1 V
Front combination lamp RH
Resistance
Terminal
5
1
Except 0
Ω