Kia Carnival (2007 year). Manual — part 247
Steering Angle Sensor
2007 > 2.7L V6 GASOLINE >
DESCRIPTION
GENERAL DATA
The steering angle speed sensor detects the angle of the steering wheel in order to which direction a user chooses.
MEASUREING PRINCIPLE
A non contact, analog angle sensor carrying out absolute measuring by the use of the Anisotropic-Magneto-Resistive
effect (AMR).Measuring of the absolute angle by means of a toothed measuring gear with magnetic properties in
combination with different ratios. Corresponding AMR elements that change their electrical resistance according to the
magnetic field direction detect the angle position of the measuring gears.A micro-controller decodes the measured
voltage signals after A/D converting with the help of a mathematical function. Output of the digital angle value and
velocity via CAN-interface.
SPECIFICATION
Description
Specification
Operating voltage
8~16 V
Operating temperature
-40 ~ 85 °C
Current consumption
Max.150 mA
Steering angle velocity
Max. ±2000 °/sec
Connection delay time
t < 200 ms
Reverse voltage
-13.5 V
Measuring range
Angle
-780 ° ~ 779 °
Angular velocity
0~ 1016 °/s
Nonlinearity angle
-2.5 ° ~ +2.5 °
Hysteresis angle
0 ° ~ 5 °
Rotational friction torque measuring
10 °/s
CIRCUIT DIAGRAM( STEERING WHEEL SPEED ANGLE SENSOR)
STEERING ANGLE SENSOR (SAS) calibration
1. PURPOSE OF calibration
a. On vehicle control, an ESP analyzes the intention of the driver.
b. An ESP recognizes a steering angle which a driver rotates through the steering angle sensor.
c. A steering angle sensor used in ESP adjusts 0° setting of steering wheel through K-line or CAN
communication.
2. STEERING ANGLE SENSOR (SAS) CALIBRATION METHOD
(1) Align the wheel to the straight line. (steering wheel < ± 5° )
ex) Perform the wheel alignment first.
Align the wheel to the straight line.
A driver moves the vehicle to the front and back about 5 meters twice or three times.
(2) Connect Scan tool to the vehicle.
(3) Select Brake system.
(4) Select Steering angle sensor(SAS) calibration.
(5) Perform the Steering angle sensor(SAS) calibration.
(6) Perform the procedure continuously.
(7) The procedure is finished. Push the "ESC" key.
(8) Scanner OFF.
(9) Remove the scanner from the vehicle.
(10) Confirm the Steering angle sensor(SAS) calibration as driving the vehicle.(turn left once, turn right once)