Kia Carens. Manual — part 320

2001 > 1.8L DOHC >

INSPECTION

Check for leakage at connections by using a gas leak tester.
Refer or replace as necessary.

REPLACEMENT

1. Discharge refrigeration system. Refer to operating instructions of your refrigerant recovery/recycling

/charging station for proper procedures.

2. Replace faulty pipe or hose.

1) Immediately plug open fittings to keep moisture out of system.
2) Apply clean compressor oil to O-rings before connecting fittings.
3) Do not apply compressor oil to fitting nuts.

3. Evacuate, charge, and test refrigeration system.

DISASSEMBLY

Disassembly A/C compressor clutch as shown in figure.

Heating,Ventilation, Air Conditioning

Air Conditioning System - Dual Pressure Switch

Heating,Ventilation, Air Conditioning

2001 > 1.8L DOHC >

INSPECTION

1. Turn ignition switch OFF.

2. Connect manifold gauge set and measure high-pressure side refrigerantpressure.

High-pressure side:Above 88 psi (608 kPa)

3. If not as specified, check refrigerant system. (refer to troubleshooting information)

4. If correct, go to next step.

5. Disconnect A/C dual pressure switch connector.

6. Check for continuity of switch.

Terminals

Continuity

A-B

Yes

7. If not as specified, replace switch.

Heating,Ventilation, Air Conditioning

Air Conditioning System - Thermistor

Heating,Ventilation, Air Conditioning