Kia Carens. Manual — part 320
2001 > 1.8L DOHC >
INSPECTION
Check for leakage at connections by using a gas leak tester.
Refer or replace as necessary.
REPLACEMENT
1. Discharge refrigeration system. Refer to operating instructions of your refrigerant recovery/recycling
/charging station for proper procedures.
2. Replace faulty pipe or hose.
1) Immediately plug open fittings to keep moisture out of system.
2) Apply clean compressor oil to O-rings before connecting fittings.
3) Do not apply compressor oil to fitting nuts.
3. Evacuate, charge, and test refrigeration system.
DISASSEMBLY
Disassembly A/C compressor clutch as shown in figure.
Heating,Ventilation, Air Conditioning
Air Conditioning System - Dual Pressure Switch
Heating,Ventilation, Air Conditioning
2001 > 1.8L DOHC >
INSPECTION
1. Turn ignition switch OFF.
2. Connect manifold gauge set and measure high-pressure side refrigerantpressure.
High-pressure side:Above 88 psi (608 kPa)
3. If not as specified, check refrigerant system. (refer to troubleshooting information)
4. If correct, go to next step.
5. Disconnect A/C dual pressure switch connector.
6. Check for continuity of switch.
Terminals
Continuity
A-B
Yes
7. If not as specified, replace switch.
Heating,Ventilation, Air Conditioning
Air Conditioning System - Thermistor
Heating,Ventilation, Air Conditioning