Kia Carens. Manual — part 314
1. Discharge refrigeration system. Refer to operating instructions of you refrigerant recovery/recycling/charging
station for proper procedures.
2. Evacuate system to remove all air and moisture from it. Refer to operating instructions of your refrigerant
recovery/recycling/charging station for proper procedures.
3. Charge system with refrigerant. Refer to operating instructions of your refrigerant recovery/recycling
/charging station for proper procedures.
4. After charging, measure refrigerant pressure. Refer to “Checking Refrigerant Pressure".
5. If low-and high-pressure sides are still too high, replace receiver/drier.
No refrigerant circulation
Measurement pressure
Low-pressure : Below 20 psi (137 kPa, 1.40 kg/cm²)
High-pressure : Below 88 psi (608 kPa, 6.20 kg/cm²)
- Condition -
Refrigerant flow obstructed by moisture or dirt, causing freezing or blockage of expansion valve.
1. Step 1
Turn air conditioner OFF for about 10 minutes. Turn air conditioner ON to determine whether blockage is
due to moisture or dirt.
A. If caused by moisture : System will operate normally after being OFF for 10 minutes. (Ice melts and
relieves blockage.).
B. If caused by dirt : System remains abnormal after being OFF 10 minutes. Go to Step 2.
2. Step 2
(1) Remove expansion valve.
(2) Blow out dirt with compressed air.
(3) If unable to remove dirt, replace expansion valve.
(4) Evacuate, charge, and test system. Refer to operating instructions of your refrigerant recovery/recycling
/charging station for proper procedures.
Expansion valve stuck open
Measured pressure
Low-pressure : Above 35.6 psi (2445 kPa, 2.50 kg/cm²)
High-pressure : Below 88 psi (608 kPa, 6.20 kg/cm²)
- Condition - Insufficient cooling
1. Check whether there is frost or heavy dew on suction pipe (between cooling unit compressor).
2. If neither is found, refer to “Excessive Refrigerant or Insufficient Condenser Cooling".
3. If either is found, replace expansion valve.
Faulty compressor
Measured pressure
Low-pressure : 57~88 psi (392~608 kPa, 4.0~6.20 kg/cm²)
High-pressure : 107~152 psi (736~1,050 kPa, 7.50~10.7 kg/cm²)
- Condition - No cooling
1. Run engine at a fast idle.
2. Verify that A/C compressor clutch is ON when A/C switch and blower switch are ON.
3. If A/C compressor clutch remains OFF, refer to “A/C Compressor Clutch does not Operate.
Manifold gauge set
Fittings for attaching manifold gauge set are on the high-and low-pressure pipes.
1. Close both hand valves of manifold gauge set.
2. Connect the low-pressure hose to high-pressure gauge fitting.
3. Tighten hose nuts by hand only.
Leak test
After evacuating system, refer to operating instructions of your refrigerant recovery/recycling charging station
for proper procedures. Check for leaks.
1. Connect a full refrigerant container to the service valve.
2. Open the high-pressure manual valve to charge system with refrigerant gas.
3. When low-pressure gauge reads 14 psi (98 kPa), close high-pressure manual valve.
4. Use a gas leak detector to check the system for leaks. If a leak is found, repair faulty component or
connection, then evacuate system again. Refer to operating instructions of your refrigerant
recovery/recycling/charging station for proper procedures.
Checking refrigerant pressure
1. Connect manifold gauge set.
2. Operate engine at 2000 rpm and set air conditioner to maximum cooling.
3. Measure low-and high-pressure sides
Normal pressure
Low-pressure side: 20~41 psi (137~285 kPa, 1.40~2.91 kg-cm²)
High-pressure side: 185~263 psi (1.275~1.815 kPa, 13.0~18.5 kg-cm²)
2001 > 1.8L DOHC >
SPECIFICATIONS
Mechanical specifications
Item
Description
Tightening torque
Blower/Evaporator assembly mounting nuts
70~96lb-in (8~11N·m, 80~110kg-cm)
Compressor mounting bracket bolts (Front side)
23~35lb-in(31~47N·m, 3.2~4.8kg-cm)
Compressor mounting bracket bolts (Left side)
12~17lb-in(16~23N·m 1.6~2.3kg-cm)
Compressor mounting bolts
18~23lb-in(24~31N·m 2.4~3.2kg-cm)
Condenser fan mounting bolts
70~96lb-in(8~11N·m 80~110kg-cm)
Condenser mounting bolts
70~96lb-in(8~11N·m 80~110kg-cm)
Heater unit mounting nuts
70~96lb-in(8~11N·m 82~110kg-cm)
Receiver/Drier mounting bolts
44~52lb-in(5~6N·m 50~60kg-cm)
Receiver/Drier mounting bracket bolts
87~131lb-in(10~15N·m 1.0~1.5kg-cm)
Others specifications
Item
Description
Specifications
Cooling
Maximum cooling capacity
(450m³/h)
4500 ± 10% kcal/h
Air volume
305 CFM (500CMH)
Power consumption
252W-12V
Heating
Maximum heating
capacity (350m³/h)
4700 ± 10%kcal/h
Air volume
213CFM (350CMH)
Power consumption
252W-12V
Compressor
Oulet flow
155.3 cc/rev.
Number of cylinder
10
Maximum speed
9000 rpm
Oil (Capacity)
120 cc
Receiver/Drier
Desiccant used
ZEOLITE
Dual pressure switch
High-pressure control
OFF : 455psi (32kg/cm²)
DIFF : 85psi (6kg/cm²)
Low-pressure control
OFF : 28psi (2kg/cm²)
DIFF : 4psi (0.25kg/cm²)
Service ports
High pressure side
M10 × 1.25
Low pressure side
M9 × 1.0
Air filter
Replacement period
12,000km or 6months
Refrigerant (Charged amount)
R-134a (800 ± 50g)