Hummer H3. Manual — part 1136
CHARGE INDICATOR INOPERATIVE
Charge Indicator Inoperative
3
2. With a scan tool, observe
the Battery Voltage
parameter in the instrument
panel cluster (IPC) data list.
Does the voltage measure within
the normal operating range?
12.5-15.5 V
Go to Step 4
Go to
Charging
System Test
4
Replace the IPC. Refer to
Control Module References
for replacement, setup and
programming.
Did you complete the
replacement?
-
Go to Step 5
-
5
Operate the system in order to
verify the repair.
Did you correct the condition?
-
System OK
Go to Step 2
Step
Action
Yes
No
1
Did you perform the Diagnostic System
Check - Vehicle?
Go to Step 2
Go to
Diagnostic
System Check
- Vehicle
2
Turn ON the ignition, with the engine OFF
observe the charge indicator on the instrument
panel cluster (IPC).
Is the charge indicator illuminated?
Go to Testing
for
Intermittent
Conditions
and Poor
Connections
Go to Step 3
3
Replace the IPC. Refer to Control Module
References for replacement, setup and
programming.
Did you complete the replacement?
Go to Step 4
-
4
Operate the system in order to verify the
repair.
Did you correct the condition?
System OK
Go to Step 2
2007 Hummer H3
2007 ENGINE Engine Electrical - H3
GENERATOR NOISE DIAGNOSIS
Diagnostic Aids
Noise from a generator may be due to electrical or mechanical noise. Electrical noise, magnetic
whine, usually varies with the electrical load placed on the generator and is a normal operating
characteristic of all generators. When diagnosing a noisy generator, it is important to remember
that loose or misaligned components around the generator may transmit the noise into the
passenger compartment and that replacing the generator may not solve the problem.
Generator Noise Diagnosis
Step
Action
Yes
No
1
Test the generator for proper operation
using the Generator Tester. Refer to
Charging System Test.
Is the generator operating properly?
Go to Step 2
Go to Step 11
2
1. Start the engine. Verify that the noise
can be heard.
2. Turn OFF the engine.
3. Disconnect the 4-way connector from
the generator.
4. Start the engine.
5. Listen for the noise.
Has the noise stopped?
Go to Step 11
Go to Step 3
3
1. Turn OFF the engine.
2. Remove the drive belt. Refer to
Drive Belt Replacement (Without
A/C) or Drive Belt Replacement
(With A/C) .
3. Spin the generator pulley by hand.
Does the generator shaft spin smoothly and
without any roughness or grinding noise?
Go to Step 4
Go to Step 11
4
Inspect the generator for a loose pulley
and/or pulley nut.
Is the generator pulley or pulley nut loose?
Go to Step 11
Go to Step 5
1. Loosen all of the generator mounting
2007 Hummer H3
2007 ENGINE Engine Electrical - H3
5
bolts.
2. Tighten the generator mounting bolts
to specifications and in the proper
sequence, if necessary. Refer to
Generator Replacement.
3. Install the drive belt. Refer to Drive
Belt Replacement (Without A/C)
or Drive Belt Replacement (With
A/C) .
4. Start the engine.
Has the noise decreased or stopped?
System OK
Go to Step 6
6
Inspect the generator for the following
conditions:
Strained or stretched electrical
connections
Hoses or other vehicle equipment
resting on the generator, which may
cause the noise to be transmitted into
the passenger compartment
Are any electrical connections pulling on
the generator or are any hoses, etc. resting
on the generator?
Go to Step 7
Go to Step 8
7
1. Reroute the electrical connections to
relieve the tension.
2. Reroute the hoses, etc. away from the
generator.
3. Start the engine.
Has the noise decreased or stopped?
System OK
Go to Step 8
8
Inspect the drive belt for proper tension.
Refer to Drive Belt Tensioner
Diagnosis .
Is the drive belt loose?
Go to Step 9
Go to Step 10
1. Replace the drive belt tensioner.
2007 Hummer H3
2007 ENGINE Engine Electrical - H3
STARTER SOLENOID DOES NOT CLICK
Starter Solenoid Does Not Click
9
Refer to Drive Belt Tensioner
Replacement .
2. Start the engine.
Has the noise decreased or stopped?
System OK
Go to Step 11
10
Compare the vehicle with a known good
vehicle.
Do both vehicles make the same noise?
System OK
Go to Step 11
11
Replace the generator. Refer to
Generator Replacement.Has the noise
decreased or stopped?
IMPORTANT:
If no definite generator problems were found,
be sure that all other possible sources of
objectionable noise are eliminated before
replacing the generator. Replacing the
generator may not change the noise level if
the noise is a normal characteristic of the
generator or the generator mounting.
Go to Step 12
-
12
Operate the system in order to verify the
repair.
Did you correct the condition?
System OK
Go to Step 2
Step
Action
Yes
No
Schematic Reference: Starting and Charging Schematics
1
Did you perform the Diagnostic System
Check - Vehicle?
Go to Step 2
Go to
Diagnostic
System Check -
Vehicle
2
Turn the ignition switch to the START
position.
Does the engine crank?
Go to Testing
for Intermittent
Conditions and
Poor
Connections
Go to Step 3
Is the security indicator flashing?
Go to
Diagnostic
2007 Hummer H3
2007 ENGINE Engine Electrical - H3