Toyota Tundra. Manual — part 2393
3. INDICATOR CHECK
a. Press and hold the A/C control AUTO switch and Recirculation/Fresh switch simultaneously, and
turn the ignition switch ON. Continue holding the 2 switches until the panel diagnosis mode begins.
Fig. 24: Identifying A/C Control Auto Switch
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
b. Check that all indicators turn on and off 4 times in succession at 1 second intervals.
HINT:
After the indicator check is completed, the system enters the DTC mode automatically.
Press the "OFF" switch to cancel the indicator check.
Fig. 25: Identifying Blinking Pattern
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
CHECK MODE PROCEDURE
1. LIST OF OPERATION METHODS
By operating each of the A/C control switches as shown in the diagram below, it is possible to enter the
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
diagnostic check mode.
Fig. 26: A/C Control Switches Flow Diagram
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
DATA LIST/ACTIVE TEST
1. READ DATA LIST
HINT:
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
Using the Techstream to read the Data List allows the values or states of switches, sensor, actuators and
other items to be read without removing any parts. This non-intrusive inspection can be very useful
because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading
the Data List information early in troubleshooting is one way to save diagnostic time.
a. Warm up the engine.
b. Turn the ignition switch OFF.
c. Connect the Techstream to the DLC3.
d. Turn the ignition switch ON.
e. Turn the Techstream on.
f. Enter the following menus: Body Electrical/(desired menu)/Data List.
g. According to the display on the Techstream, read the "Data List".
Air Conditioner
DATA LIST
NOTE:
In the table below, the values listed under "Normal Condition" are
reference values. Do not depend solely on these reference values when
deciding whether a part is faulty or not.
Tester Display
Measurement Item/Range
Normal Condition
Diagnostic
Note
Room Temperature
Sensor
Room temperature sensor/Min.: -
6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature
for front seat is displayed
Open in circuit:
-6.5°C (20.3°F)
Short in circuit:
57.25°C
(135.05°F)
Ambient Temp
Sensor
Ambient temperature
sensor/Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient
temperature is displayed
Open in circuit:
-23.3°C (-9.94°
F)
Short in circuit:
65.95°C
(150.71°F)
Evaporator Fin
Thermistor
Evaporator fin thermistor/Min.:-
29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator
temperature is displayed
Open in circuit:
-29.7°C (-
21.46°F)
Short in circuit:
59.55°C
(139.19°F)
Solar Sensor (D
Side)
Driver side solar sensor/Min.: 0,
Max.: 255
Driver side solar sensor
voltage increases as
brightness increases
Open in circuit:
0
Short in circuit:
255
Solar Sensor (P
Passenger side solar sensor/Min.: Passenger side solar
Open in circuit:
0
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
Side)
0, Max.: 255
sensor voltage increases
as brightness increases
Short in circuit:
255
Engine Coolant
Temp
Engine coolant temperature/Min.:
1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant
temperature is displayed
while engine is warrmed
up
-
Set Temperature (D
Side)
Driver side set temperature/Min.:
0, Max.: 255
Driver side actual set
temperature is displayed
-
Set Temperature (P
Side)
Passenger side set
temperature/Min.: 0, Max.: 255
Passenger side actual set
temperature is displayed
-
Blower Motor
Speed Level
Blower motor speed level/Min.: 0
level, Max.: 31 level
Increases in range
between 0 and 31 as
blower motor speed
increases
-
Adjusted Ambient
Temperature
Adjusted ambient
temperature/Min.: -30.8°C (-
23.44°F)
Max.: 50.8°C (123.44°F)
Adjusted ambient
temperature is displayed
-
Air Mix Servo Targ
Pulse (D)
Driver side air mix servo motor
target pulse/Min.: 5, Max.: 104
MAX. COLD: 5 (pulse)
MAX. HOT: 104 (pulse)
-
Air Mix Servo Targ
Pulse (P)
Passenger side air mix servo
motor target pulse/Min.: 6, Max.:
105
MAX. COLD: 105
(pulse)
MAX. HOT: 6 (pulse)
-
Air Outlet Servo
Pulse (D)
Driver side air outlet servo motor
target pulse/Min.: 9, Max.: 97
FACE: 9 (pulse)
B/L: 32 (pulse)
FOOT: 56 (pulse)
FOOT/DEF: 83 (pulse)
DEF: 97 (pulse)
-
Air Inlet Damper
Targ Pulse
Air inlet damper target
pulse/Min.: 7, Max.: 28
REC: 7
FRS: 28
-
Cool Air Bypass
Pulse
Cool air bypass servo motor
target pulse/Min.: 8, Max.: 50
Open: 8 (pulse)
Close: 50 (pulse)
-
Shin Set
Temperature
Shift set temperature/+2 C, +1 C,
Normal, -1 C, -2 C
Customized value will be
displayed
-
Air Inlet Mode
Air inlet mode/Auto, Manual
Customized value will be
displayed
-
Compressor Mode Compressor mode/Auto, Manual
Customized value will be
displayed
-
Compressor/DEF
Mode
Compressor/DEF mode/Link,
Normal
Customized value will be
displayed
-
Foot/DEF Auto
Mode
FOOT/DEF auto mode/ON, OFF
Customized value will be
displayed
-
Foot/DEF Auto
Blow Up
FOOT/DEF auto blower up
function/ON, OFF
Customized value will be
displayed
-
Ambient
Ambient temperature shift/+3 C, Customized value will be
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.