Toyota Tundra. Manual — part 2420
Fig. 107: Ambient Temperature Sensor - Wiring Diagram
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
INSPECTION PROCEDURE
1. READ VALUE USING TECHSTREAM (AMBIENT TEMPERATURE SENSOR)
a. Use the Data List to check if the ambient temperature sensor is functioning properly.
Air Conditioner
DATA LIST
OK:
The display is as specified in the normal condition.
Result
RESULT REFERENCE
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS
Tester
Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp
Sensor
Ambient temperature
sensor/Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient
temperature is displayed
Open in circuit: -23.3°
C (-9.94°F)
Short in circuit: 65.95°
C (150.71°F)
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
TABLE (See PROBLEM SYMPTOMS TABLE )
C: REPLACE AIR CONDITIONING AMPLIFIER (See REMOVAL )
A: Go to Next Step
2. INSPECT AMBIENT TEMPERATURE SENSOR
a. Remove the ambient temperature sensor (see REMOVAL ).
Fig. 108: Temperature And Resistance Graph
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
b. Measure the resistance according to the value(s) in the table below.
Standard Resistance
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
TESTER CONNECTION SPECIFIED CONDITION CHART
HINT:
As the temperature increases, the resistance decreases (see the graph ).
NG: REPLACE AMBIENT TEMPERATURE SENSOR (See REMOVAL )
OK: Go to Next Step
3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR
CONDITIONING AMPLIFIER)
a. Disconnect the A15 sensor connector.
b. Disconnect the J19 air conditioning amplifier connector.
Tester Connection Condition Specified Condition
1 - 2
10°C (50°F) 3.00 to 3.73 kohms
15°C (59°F) 2.45 to 2.88 kohms
20°C (68°F) 1.95 to 2.30 kohms
25°C (77°F) 1.60 to 1.80 kohms
30°C (86°F) 1.28 to 1.47 kohms
35°C (95°F) 1.00 to 1.22 kohms
40°C (104°F) 0.80 to 1.00 kohms
45°C (113°F) 0.65 to 0.85 kohms
50°C (122°F) 0.50 to 0.70 kohms
55°C (131°F) 0.44 to 0.60 kohms
60°C (140°F) 0.36 to 0.50 kohms
NOTE:
Even slightly touching the sensor may change the resistance
value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as
the ambient temperature.
2009 Toyota Tundra
2009 HVAC Air Conditioning - Tundra
Fig. 109: Identifying Terminals Of J19 Air Conditioning Amplifier Connector
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
c. Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHART
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE AIR CONDITIONING AMPLIFIER (See REMOVAL )
DTC B1413/13 EVAPORATOR TEMPERATURE SENSOR CIRCUIT
DESCRIPTION
Tester Connection
Condition Specified Condition
A15-1 - J19-5 (TAM)
Always
Below 1 ohms
A15-2 - J19-13 (SG-2)
A15-1 or J19-5 (TAM) - Body ground
Always
10 kohms or higher
A15-2 or J19-13 (SG-2) - Body ground