Toyota Tundra (2015 year). Manual — part 2338
INSPECTION PROCEDURE
PROCEDURE
1.
READ VALUE USING TECHSTREAM (DOOR CONTROL SWITCH)
TESTER DISPLAY
MEASUREMENT ITEM/RANGE
NORMAL CONDITION
DIAGNOSTIC
NOTE
DOOR LOCK: POWER DOOR LOCK CONTROL SYSTEM: Door Contr...
TESTER DISPLAY
MEASUREMENT ITEM/RANGE
NORMAL CONDITION
DIAGNOSTIC
NOTE
Door Lock
SW-Lock
Door control switch lock
signal
/ ON or OFF
ON: Door control switch is pushed to lock
position
OFF: Door control switch is not pushed
-
Door Lock
SW-Unlock
Door control switch unlock
signal
/ ON or OFF
ON: Door control switch is pushed to
unlock position
OFF: Door control switch is not pushed
-
OK:
The display is as specified in the normal condition column.
Result
RESULT
PROCEED TO
OK
A
NG (for Driver Side)
B
NG (for Passenger Side)
C
B
GO TO STEP 2
C
GO TO STEP 4
A
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN
PROBLEM SYMPTOMS TABLE
2.
INSPECT POWER WINDOW REGULATOR MASTER SWITCH
DOOR LOCK: POWER DOOR LOCK CONTROL SYSTEM: Door Contr...
OK
(a) Remove the master switch
.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
for Regular Cab
except Regular Cab
TESTER CONNECTION
SWITCH CONDITION
SPECIFIED CONDITION
1 (L) - 7 (E)
Lock
Below 1 Ω
1 (L) - 7 (E)
OFF (Free)
10 kΩ or higher
9 (UL) - 7 (E)
9 (UL) - 7 (E)
Unlock
Below 1 Ω
TESTER CONNECTION
SWITCH CONDITION
SPECIFIED CONDITION
2 (L) - 1 (E)
Lock
Below 1 Ω
2 (L) - 1 (E)
OFF (Free)
10 kΩ or higher
9 (UL) - 1 (E)
9 (UL) - 1 (E)
Unlock
Below 1 Ω
NG
REPLACE POWER WINDOW REGULATOR MASTER
SWITCH
3.
CHECK HARNESS AND CONNECTOR (DOOR LOCK SWITCH - MAIN BODY ECU)
(a) Disconnect the N2 switch connector.
DOOR LOCK: POWER DOOR LOCK CONTROL SYSTEM: Door Contr...
(b) Disconnect the DD ECU connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
for Regular Cab
except Regular Cab
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
N2-1 (L) - DD-49 (L1)
Always
Below 1 Ω
N2-9 (UL) - DD-52 (UL1)
N2-7 (E) - Body ground
DD-49 (L1) - Body ground
Always
10 kΩ or higher
DD-52 (UL1) - Body ground
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
N2-2 (L) - DD-49 (L1)
Always
Below 1 Ω
N2-9 (UL) - DD-52 (UL1)
N2-1 (E) - Body ground
DD-49 (L1) - Body ground
Always
10 kΩ or higher
DD-52 (UL1) - Body ground
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE MAIN BODY ECU
4.
INSPECT DOOR CONTROL SWITCH
(a) Remove the door control switch
.
(b) Measure the resistance according to the value(s) in the
table below.
Standard resistance:
TESTER CONNECTION SWITCH CONDITION SPECIFIED CONDITION
4 (L) - 3 (E)
Lock
Below 1 Ω
4 (L) - 3 (E)
OFF
10 kΩ or higher
2 (UL) - 3 (E)
2 (UL) - 3 (E)
Unlock
Below 1 Ω
DOOR LOCK: POWER DOOR LOCK CONTROL SYSTEM: Door Contr...