Toyota Tundra (2015 year). Manual — part 1552
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the Techstream. Freeze frame data records the engine condition when
malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle
was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and
other data from the time the malfunction occurred.
PROCEDURE
1.
INSPECT IGNITION COIL (POWER SOURCE)
3UR-FBE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0351-P0358...
OK
(a) Disconnect the D10, D12, D14, D16, D19, D21, D23 or
D25 ignition coil connector.
(b) Measure the resistance according to the value(s) in the
table below.
Standard resistance:
TESTER CONNECTION
CONDITION SPECIFIED CONDITION
D10-4 (GND) - Body ground
Always
Below 1 Ω
D25-4 (GND) - Body ground
Always
Below 1 Ω
D12-4 (GND) - Body ground
Always
Below 1 Ω
D23-4 (GND) - Body ground
Always
Below 1 Ω
D14-4 (GND) - Body ground
Always
Below 1 Ω
D21-4 (GND) - Body ground
Always
Below 1 Ω
D16-4 (GND) - Body ground
Always
Below 1 Ω
D19-4 (GND) - Body ground
Always
Below 1 Ω
(c) Turn the ignition switch to ON.
(d) Measure the voltage according to the value(s) in the
table below.
Standard voltage:
TESTER CONNECTION
SWITCH
CONDITION
SPECIFIED
CONDITION
D10-1 (+B) - D10-4
(GND)
Ignition switch ON
11 to 14 V
D25-1 (+B) - D25-4
(GND)
Ignition switch ON
11 to 14 V
D12-1 (+B) - D12-4
(GND)
Ignition switch ON
11 to 14 V
D23-1 (+B) - D23-4
(GND)
Ignition switch ON
11 to 14 V
D14-1 (+B) - D14-4
(GND)
Ignition switch ON
11 to 14 V
D21-1 (+B) - D21-4
(GND)
Ignition switch ON
11 to 14 V
D16-1 (+B) - D16-4
(GND)
Ignition switch ON
11 to 14 V
D19-1 (+B) - D19-4
(GND)
Ignition switch ON
11 to 14 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
3UR-FBE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0351-P0358...
2.
CHECK HARNESS AND CONNECTOR (IGNITION COIL - ECM)
(a) Disconnect the D10, D12, D14, D16, D19, D21, D23 or D25 ignition coil connector.
(b) Disconnect the D74 ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
D10-2 (IGF1) - D74-104 (IGF1)
Always
Below 1 Ω
D25-2 (IGF2) - D74-105 (IGF2)
Always
Below 1 Ω
D12-2 (IGF2) - D74-105 (IGF2)
Always
Below 1 Ω
D23-2 (IGF1) - D74-104 (IGF1)
Always
Below 1 Ω
D14-2 (IGF2) - D74-105 (IGF2)
Always
Below 1 Ω
D21-2 (IGF1) - D74-104 (IGF1)
Always
Below 1 Ω
D16-2 (IGF1) - D74-104 (IGF1)
Always
Below 1 Ω
D19-2 (IGF2) - D74-105 (IGF2)
Always
Below 1 Ω
D10-3 (IGT1) - D74-40 (IGT1)
Always
Below 1 Ω
D25-3 (IGT2) - D74-33 (IGT2)
Always
Below 1 Ω
D12-3 (IGT3) - D74-37 (IGT3)
Always
Below 1 Ω
D23-3 (IGT4) - D74-34 (IGT4)
Always
Below 1 Ω
D14-3 (IGT5) - D74-35 (IGT5)
Always
Below 1 Ω
D21-3 (IGT6) - D74-36 (IGT6)
Always
Below 1 Ω
D16-3 (IGT7) - D74-38 (IGT7)
Always
Below 1 Ω
D19-3 (IGT8) - D74-39 (IGT8)
Always
Below 1 Ω
D10-2 (IGF1) or D74-104 (IGF1) - Body ground
Always
10 kΩ or higher
D25-2 (IGF2) or D74-105 (IGF2) - Body ground
Always
10 kΩ or higher
D12-2 (IGF2) or D74-105 (IGF2) - Body ground
Always
10 kΩ or higher
D23-2 (IGF1) or D74-104 (IGF1) - Body ground
Always
10 kΩ or higher
D14-2 (IGF2) or D74-105 (IGF2) - Body ground
Always
10 kΩ or higher
D21-2 (IGF1) or D74-104 (IGF1) - Body ground
Always
10 kΩ or higher
D16-2 (IGF1) or D74-104 (IGF1) - Body ground
Always
10 kΩ or higher
D19-2 (IGF2) or D74-105 (IGF2) - Body ground
Always
10 kΩ or higher
D10-3 (IGT1) or D74-40 (IGT1) - Body ground
Always
10 kΩ or higher
D25-3 (IGT2) or D74-33 (IGT2) - Body ground
Always
10 kΩ or higher
D12-3 (IGT3) or D74-37 (IGT3) - Body ground
Always
10 kΩ or higher
D23-3 (IGT4) or D74-34 (IGT4) - Body ground
Always
10 kΩ or higher
3UR-FBE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0351-P0358...
OK
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
D14-3 (IGT5) or D74-35 (IGT5) - Body ground
Always
10 kΩ or higher
D21-3 (IGT6) or D74-36 (IGT6) - Body ground
Always
10 kΩ or higher
D16-3 (IGT7) or D74-38 (IGT7) - Body ground
Always
10 kΩ or higher
D19-3 (IGT8) or D74-39 (IGT8) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
3.
CHECK WHETHER DTC OUTPUT RECURS (DTC P0351, P0352, P0353, P0354,
P0355, P0356, P0357 OR P0358)
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON and turn the Techstream on.
(c) Clear DTCs
.
Do not shuffle the connectors.
(e) Perform a simulation test.
(f) Check DTCs displayed on the Techstream.
Result
RESULT
PROCEED TO
Same DTC is output
A
Different ignition coil DTC is output
B
B
REPLACE IGNITION COIL
A
REPLACE ECM
3UR-FBE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0351-P0358...