Toyota Tundra (2015 year). Manual — part 522
Last Modified: 9-16-2014
6.6 G
Doc ID: RM000000ODH05UX
Model Year: 2015
Model: Tundra
Prod Date Range: [08/2014 - ]
Title: A760F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY: INSPECTION; 2015 MY Tundra [08/2014 -
]
INSPECTION
1. INSPECT SHIFT SOLENOID VALVE SL1
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) with a 21 W bulb
→ Terminal 1
Battery negative (-) → Terminal 2
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
2. INSPECT SHIFT SOLENOID VALVE S1
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S1 connector
terminal - Shift solenoid valve S1
body
20°C
(68°F)
11 to 15 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
A760F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid
valve S1 connector
Battery negative (-) → Shift solenoid
valve S1 body
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
3. INSPECT SHIFT SOLENOID VALVE S2
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S2 connector
terminal - Shift solenoid valve S2
body
20°C
(68°F)
11 to 15 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid
valve S2 connector
Battery negative (-) → Shift solenoid
valve S2 body
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
4. INSPECT SHIFT SOLENOID VALVE S3
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S3 connector
terminal - Shift solenoid valve S3
body
20°C
(68°F)
11 to 15 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
A760F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid
valve S3 connector
Battery negative (-) → Shift solenoid
valve S3 body
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
5. INSPECT SHIFT SOLENOID VALVE S4
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S4 connector
terminal - Shift solenoid valve S4
body
20°C
(68°F)
11 to 15 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid
valve S4 connector
Battery negative (-) → Shift solenoid
valve S4 body
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
A760F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
6. INSPECT SHIFT SOLENOID VALVE SL2
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) with a 21 W bulb
→ Terminal 1
Battery negative (-) → Terminal 2
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.
7. INSPECT SHIFT SOLENOID VALVE SR
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve SR connector
terminal - Shift solenoid valve SR
body
20°C
(68°F)
11 to 15 Ω
(b) Apply 12 V battery voltage to the shift solenoid valve and check
that the valve moves and makes an operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid
valve SR connector
Battery negative (-) → Shift solenoid
valve SR body
Valve moves and makes an
operating noise
If the result is not as specified, replace the solenoid valve.