Toyota Tundra (2015 year). Manual — part 836
Last Modified: 9-16-2014
6.6 F
Doc ID: RM000002J2C02QX
Model Year: 2015
Model: Tundra
Prod Date Range: [08/2014 - ]
Title: SERVICE SPECIFICATIONS: 1UR-FE COOLING: SERVICE DATA; 2015 MY Tundra [08/2014 - ]
SERVICE DATA
Thermostat
Standard valve opening temperature
80 to 84°C (176 to 183°F)
Standard valve lift
10 mm (0.394 in.) or more at 95°C (203°F)
Radiator cap
Standard valve (for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm
2
, 13.5 to 17.8 psi)
Minimum standard valve (after using cap)
78.5 kPa (0.8 kgf/cm
2
, 11.4 psi)
Fin for blockage
300 mm (11.8 in.)
2942 to 4903 kPa (30.0 to 50.0 kgf/cm
2
, 427 to 711 psi)
500 mm (19.7 in.)
4903 to 7845 kPa (50.0 to 80.0 kgf/cm
2
, 711 to 1138 psi)
SERVICE SPECIFICATIONS: 1UR-FE COOLING: SERVICE DATA; ...
Last Modified: 9-16-2014
6.6 F
Doc ID: RM000002J2D022X
Model Year: 2015
Model: Tundra
Prod Date Range: [08/2014 - ]
Title: SERVICE SPECIFICATIONS: 1UR-FE COOLING: TORQUE SPECIFICATIONS; 2015 MY Tundra [08/2014 -
]
TORQUE SPECIFICATIONS
Cylinder block drain cock plug
PART TIGHTENED
N*M
KGF*CM
FT.*LBF
Cylinder block drain cock plug LH and RH x Cylinder block
13
130
9
Water pump
PART TIGHTENED
N*M
KGF*CM
FT.*LBF
Water pump x Timing chain cover
for 12 mm head (Long)
23
235
17
for 12 mm head (short)
20
204
15
for 14 mm head
47
479
35
Water pump pulley x Water pump
21
214
15
Water inlet housing x Timing chain cover
21
214
15
Water by-pass pipe x Timing chain cover
10
102
7
Thermostat
PART TIGHTENED
N*M
KGF*CM
FT.*LBF
Water inlet with thermostat x Water inlet housing
10
102
7
Air tube assembly LH x Intake manifold
10
102
7
Air tube assembly LH x Water inlet housing
10
102
7
Fan
PART TIGHTENED
N*M
KGF*CM
FT.*LBF
Fan x Fluid coupling
10
102
7
Fan shroud x Radiator
6.5
66
58 in.*lbf
Fluid coupling x Fan pulley
21
214
15
Radiator
PART TIGHTENED
N*M
KGF*CM
FT.*LBF
Radiator x Radiator support
18
184
13
SERVICE SPECIFICATIONS: 1UR-FE COOLING: TORQUE SPECI...
Last Modified: 9-16-2014
6.6 F
Doc ID: RM0000033N1022X
Model Year: 2015
Model: Tundra
Prod Date Range: [08/2014 - ]
Title: SERVICE SPECIFICATIONS: 1UR-FE EMISSION CONTROL: SERVICE DATA; 2015 MY Tundra [08/2014 -
]
SERVICE DATA
EGR VALVE:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
18 to 22 Ω
2 - 3
4 - 5
5 - 6
AIR PUMP (Standard Current):
CONDITION
SPECIFIED CONDITION
20°C (68°F)
10 to 40 A
AIR PUMP (Standard Resistance):
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 (APH+) - 3 (APHG)
-20°C (-4°F)
4.4 to 20.0 Ω
-10°C (14°F)
3.9 to 18.0 Ω
0°C (32°F)
3.5 to 16.0 Ω
10°C (50°F)
3.2 to 15.0 Ω
20°C (68°F)
3.0 to 14.0 Ω
AIR SWITCHING VALVE (for Bank 1):
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 5
20°C (68°F)
4.5 to 5.5 Ω
1 - Body ground
Always
1 MΩ or higher
5 - Body ground
AIR SWITCHING VALVE (for Bank 2):
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 5
20°C (68°F)
4.5 to 5.5 Ω
1 - Body ground
Always
1 MΩ or higher
5 - Body ground
SERVICE SPECIFICATIONS: 1UR-FE EMISSION CONTROL: SER...
PURGE VALVE:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
23 to 26 Ω
1 - VSV body ground
Always
10 MΩ or higher
2 - VSV body ground
10 MΩ or higher
SERVICE SPECIFICATIONS: 1UR-FE EMISSION CONTROL: SER...