Toyota Tundra (2015 year). Manual — part 777
If the result is not as specified, replace the solenoid valve.
3. INSPECT SHIFT SOLENOID VALVE S2
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S2 connector
terminal - Shift solenoid valve S2
body
20°C
(68°F)
11 to 15 Ω
solenoid valve body. Then check that the valve moves and
makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
4. INSPECT SHIFT SOLENOID VALVE S3
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S3 connector
terminal - Shift solenoid valve S3
body
20°C
(68°F)
11 to 15 Ω
solenoid valve body. Then check that the valve moves and
makes an operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
AB60F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
5. INSPECT SHIFT SOLENOID VALVE S4
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve S4 connector
terminal - Shift solenoid valve S4
body
20°C
(68°F)
11 to 15 Ω
solenoid valve body. Then check that the valve moves and
makes an operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
6. INSPECT SHIFT SOLENOID VALVE SL2
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
(b) Connect the battery's positive (+) lead with a 21 W bulb to
operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
AB60F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
7. INSPECT SHIFT SOLENOID VALVE SR
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED
CONDITION
Shift solenoid valve SR connector
terminal - Shift solenoid valve SR
body
20°C
(68°F)
11 to 15 Ω
solenoid valve body. Then check that the valve moves and
makes an operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
8. INSPECT SHIFT SOLENOID VALVE SLT
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
(b) Connect the battery's positive (+) lead with a 21 W bulb to
operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
AB60F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...
9. INSPECT SHIFT SOLENOID VALVE SLU
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
(b) Connect the battery's positive (+) lead with a 21 W bulb to
operating noise.
OK:
Valve moves and makes an operating noise.
If the result is not as specified, replace the solenoid valve.
AB60F AUTOMATIC TRANSMISSION: VALVE BODY ASSEMBLY:...