Ford Galaxy / Ford S-MAX. Manual — part 773
CHECK the turn signal lamps.
4
Is the right-hand rear turn signal lamp on continuously?
Yes
LOCATE and RECTIFY the short to battery voltage in the circuit between the
rear lamp assembly and the Smart Junction Box with the aid of the Wiring
Diagrams. CHECK system operates correctly
No
CHECK the Smart Junction Box and RENEW it if required. CHECK system
operates correctly
E6: RULE OUT THE LEFT-HAND DOOR CONTROL MODULE AS THE CAUSE OF THE
FAULT
Ignition switch in position 0.
1
Disconnect Left-hand door control module from connector C5PL01B.
2
Ignition switch in position II.
3
CHECK the turn signal lamp.
4
Is the integrated turn signal lamp in the left-hand exterior mirror permanently
lit?
Yes
LOCATE and RECTIFY the short to battery voltage in the circuit between the
door control module and the integrated turn signal lamp in the exterior
mirror using the Wiring Diagrams. CHECK system operates correctly
No
CHECK and if necessary RENEW the door control module. CHECK system
operates correctly If the concern persists:
REFER to:
Communications Network
(418-00 Module Communications
Network, Diagnosis and Testing).
E7: RULE OUT THE RIGHT-HAND DOOR CONTROL MODULE AS THE CAUSE OF THE
FAULT
Ignition switch in position 0.
1
Disconnect Right-hand door control module from connector C6PL01B.
2
Ignition switch in position II.
3
CHECK the turn signal lamp.
4
Is the integrated turn signal lamp in the right-hand exterior mirror permanently
lit?
Yes
LOCATE and RECTIFY the short to battery voltage in the circuit between the
door control module and the integrated turn signal lamp in the exterior
mirror using the Wiring Diagrams. CHECK system operates correctly
No
CHECK and if necessary RENEW the door control module. CHECK system
operates correctly If the concern persists:
REFER to:
Communications Network
(418-00 Module Communications
Network, Diagnosis and Testing).
Exterior Lighting - Fog Lamps
S-MAX/Galaxy 2006.5 (02/2006-)
Diagnosis and Testing
Refer to Wiring Diagrams Section 417-01, for schematic and connector
information.
Special Tool(s)
Inspection and Testing
NOTE: The generic electronic module (GEM) is part of the central junction box (CJB).
NOTE: A new GEM needs to be configured after installation. For this purpose, the vehicle-
specific data are read out of the module to be changed using WDS and is transferred to
the new module. REFER to:
Module Configuration
(418-01 Module Configuration, General Procedures),
Generic Electronic Module (GEM)
(419-10 Multifunction Electronic Modules, Diagnosis and
Testing).
NOTE: Before reading out the vehicle-specific data make sure that all electrical
connections in the vehicle are reconnected so that the module and WDS can communicate
correctly.
1. 1. Verify the customer concern.
2. 2. Visually inspect for obvious signs of electrical damage.
Visual Inspection Chart
3. 3. Resolve any obvious causes or concerns found during the visual inspection before
carrying out any further tests.
4. 4. If the cause of the concern cannot be found by visual inspection, continue with the
symptom chart.
Symptom chart
Symptom chart
Terminal Probe Kit
29-011A
Electrical
Fuse(s)
Bulb(s)
Connector
Switch
Wiring loom
Symptom
Possible Sources
Action
The fog lamps are inoperative
Fuse(s)
Circuit(s)
Lights Control Module
Smart Junction Box
*
*
*
*
GO to Pinpoint Test
A.
*
One or more fog lamps inoperative
Circuit(s)
Front fog lamps
Tailgate lamps assembly
Smart Junction Box
*
*
*
*
GO to Pinpoint Test
B.
*
Pinpoint test
NOTE: Use a digital multimeter for all electrical measurements.
The Fog Lamps are On Continuously
Circuit(s)
Lights Control Module
Tailgate lamps assembly
Trailer socket
*
*
*
*
GO to Pinpoint Test
C.
*
PINPOINT TEST A : THE FOG LAMPS ARE INOPERATIVE
TEST CONDITIONS
DETAILS/RESULTS/ACTIONS
A1: CHECK FUSE F33 (5 A) (EJB)
Ignition switch in position 0.
1
Disconnect fuse F33 (5 A) (EJB).
2
CHECK fuse F33 (5 A) (EJB).
3
Is the fuse OK.?
Yes
GO to A2
.
No
RENEW fuse F33 (5 A) (EJB) and CHECK the
operation of the system. If the fuse blows again,
LOCATE and RECTIFY the short to ground using the
Wiring Diagrams. CHECK system operates correctly
A2: CHECK THE VOLTAGE SUPPLY TO FUSE F33 (5 A) (EJB) FOR OPEN CIRCUIT
Connect fuse F33 (5 A) (EJB).
1
Ignition switch in position II.
2
Measure the voltage between fuse F33 (5 A) (EJB)
and ground.
3
Does meter display battery voltage?
Yes
GO to A3
.
No
LOCATE AND RECTIFY the break in the voltage
supply of fuse F33 (5 A) (EJB) with the aid of the
wiring diagrams. CHECK system operates correctly
A3: CHECK FUSE F17 (60 A) (EJB)
Ignition switch in position 0.
1
Disconnect fuse F17 (60 A) (EJB).
2
CHECK fuse F17 (60 A) (EJB).
3
Is the fuse OK.?
Yes
GO to A4
.
No
RENEW fuse F17 (60 A) (EJB) and CHECK the
operation of the system. If the fuse blows again,
LOCATE and RECTIFY the short to ground using the
Wiring Diagrams. CHECK system operates correctly
A4: CHECK THE VOLTAGE SUPPLY TO FUSE F17 (60 A) (EJB) FOR OPEN CIRCUIT
Connect fuse F17 (60 A) (EJB).
1
Ignition switch in position II.
2
Measure the voltage between fuse F17 (60 A)
(EJB) and ground.
3
Does the meter display battery voltage?
Yes
GO to A5
.
No
LOCATE AND RECTIFY the break in the voltage
supply of fuse F17 (60 A) (EJB) with the aid of the
wiring diagrams. CHECK system operates correctly
A5: CHECK FUSE F18 (60 A) (EJB)
Ignition switch in position 0.
1
Disconnect fuse F18 (60 A) (EJB).
2
CHECK fuse F18 (60 A) (EJB).
3
Is the fuse OK.?
Yes
GO to A6
.
No
RENEW fuse F18 (60 A) (EJB) and CHECK the
operation of the system. If the fuse blows again,
LOCATE and RECTIFY the short to ground using the
Wiring Diagrams. CHECK system operates correctly
A6: CHECK THE VOLTAGE SUPPLY TO FUSE F18 (60 A) (EJB) FOR OPEN CIRCUIT
Connect fuse F18 (60 A) (EJB).
1
Ignition switch in position II.
2
Measure the voltage between fuse F18 (60 A)
(EJB) and ground.
3
Does the meter display battery voltage?
Yes
GO to A7
.
No
LOCATE AND RECTIFY the break in the voltage
supply of fuse F18 (60 A) (EJB) with the aid of the
wiring diagrams. CHECK system operates correctly
A7: CHECK THE VOLTAGE SUPPLY TO THE LIGHTS CONTROL MODULE FOR OPEN
CIRCUIT
Ignition switch in position 0.
1
Disconnect Lights control module from connector
C2LF23D.
2
Ignition switch in position II.
3
Measure the voltage between the lights control
module, connector C2LF23D, pin 1, circuit SBB33B
(RD), wiring harness side and ground.
4
Does the meter display battery voltage?
Yes
GO to A8
.
No
LOCATE and RECTIFY the break in the circuits
between fuse F33 (5 A) (EJB) and the lights control
module with the aid of the wiring diagrams. CHECK
system operates correctly
A8: CHECK THE GROUND CONNECTION OF THE LIGHTS CONTROL MODULE FOR OPEN
CIRCUIT
Ignition switch in position 0.
1
Measure the resistance between the lights control
module, connector C2LS23D, pin 5, circuit
GD133BT (BK), wiring harness side and ground.
2