Is the voltage greater than 10 volts?
Yes
GO to B4
.
No
INSTALL a new BJB. TEST the system for normal
operation.
B4: CHECK CIRCUIT CDC35 (BU/WH) FOR CONTINUITY
Ignition switch in position 0.
1
Measure the resistance between the BJB starter
relay R1 connector pin 5 and the starter motor
solenoid C1DC35-B pin 1, circuit CDC35B (BU/WH).
2
Is the resistance less than 1 ohm?
Yes
INSTALL a new starter relay. TEST the system for
normal operation. If the concern persists, INSTALL
a new BJB. TEST the system for correct operation.
No
REPAIR circuit CDC35A (BU/WH) or circuit CDC35B
(BU/WH) as necessary. TEST the system for correct
operation.
PINPOINT TEST C : THE ENGINE CRANKS SLOWLY
TEST CONDITIONS
DETAILS/RESULTS/ACTIONS
C1: CHECK THE BATTERY VOLTAGE AND CONDITION
CHECK the battery using a battery tester.
1
Is the battery voltage and condition OK?
Yes
GO to C2
.
No
CHARGE or install a new battery as required.
CHECK the charging system using WDS. TEST the
system for normal operation.
C2: CHECK CIRCUIT SBF01A (RD) FOR VOLTAGE DROP
Ignition switch in position III.
1
Measure the voltage between starter motor
solenoid C1DC35-A-1 circuit SBF01A (RD),
component side and the battery positive terminal.
2
Is the voltage less than 2 volts?
Yes
GO to C3
.
No
CLEAN and TIGHTEN all battery positive cables
connections. TEST the system for normal operation.
If the concern persists, INSTALL a new battery to
starter motor solenoid cable. TEST the system for
normal operation.
C3: CHECK FOR GROUND CONNECTION
Ignition switch in position III.
1
Measure the voltage between the starter motor
housing and the battery negative terminal.
2
Is the voltage less than 2 volts?
Yes
INSTALL a new starter motor.
REFER to:
Starter Motor
(303-06A Starting System
- 2.0L Duratec-HE (107kW/145PS) - MI4/2.0L
Duratec-HE Flex Fuel (107kW/145PS) - MI4/2.3L
Duratec-HE (118kW/160PS) - MI4, Removal and
Installation) /
Starter Motor (303-06B Starting System - 2.5L
Duratec-ST (VI5), Removal and Installation) /
Starter Motor (303-06C Starting System - 1.8L
Duratorq-TDCi (Kent) Diesel, Removal and
Installation) /
Starter Motor (303-06D Starting System - 2.0L
Duratorq-TDCi (DW) Diesel, Removal and
Installation).
TEST the system for normal operation.
No
CLEAN and TIGHTEN all battery negative cable
connections and starter motor mountings. TEST the
system for normal operation. If the concern
persists, INSTALL a new battery negative cable.
TEST the system for normal operation.
Starting System - 1.8L Duratorq-TDCi
(74kW/100PS) - Lynx/1.8L Duratorq-
TDCi (92kW/125PS) - Lynx - Starter
Motor
S-MAX/Galaxy 2006.5 (02/2006-)
Removal and Installation
Removal
NOTE: Removal steps in this procedure may contain installation details.
1. Disconnect the battery ground cable.
Refer to:
Battery Disconnect and Connect
(414-
01 Battery, Mounting and Cables, General
Procedures).
2. Torque: 24 Nm
3. Raise and support the vehicle.
Refer to:
Lifting
(100-02 Jacking and Lifting,
Description and Operation).
4.
5.
1. Torque: 6 Nm
2. Torque: 12 Nm
6. Torque: 24 Nm
Installation
7. Torque: 40 Nm
1. To install, reverse the removal procedure.