Ford Ranger EV (2001 year). Manual — part 77

412-02-13

412-02-13

Heating and Ventilation

DIAGNOSIS AND TESTING (Continued)

PINPOINT TEST E: DTC C1776 HEATER SYSTEM FAILURE

TEST STEP

ACTION TO TAKE

E9 CHECK PTC HEATER CORE B CONTROL CIRCUIT FOR

SHORT TO GROUND

With key OFF, disconnect BOB from IAA module; leave BOB

Yes =

GO to E10.

connected to IAA module C1945.

With key OFF, measure the resistance between BOB pin 34 and ground

No =

REPLACE the IAA module.

(BOB pin 80).

REFER to

Section 412-04

.

Is the resistance less than 7,000 ohms?

E10 CHECK CIRCUIT 3261 (PK/Y) FOR SHORT TO GROUND

Reconnect the 12-volt auxiliary battery negative cable.

Yes =

REPLACE the PTC

switching module. REFER

to

Section 412-04

.

With key OFF, disconnect PTC switching module C1999 and measure

No =

REPAIR the PK/Y wire.

the resistance between BOB pin 34 and ground (BOB pin 80).

Is the resistance greater than 10,000 ohms?

E11 CHECK PTC HEATER CORES

Disconnect the 12-volt auxiliary battery negative cable.

Yes =

GO to E12.

Remove the high-voltage power distribution box (HVPDB) cover.

No =

REPLACE the PTC heater

Disconnect PTC switching module high-voltage C1912 and measure the

core.

resistance between the DB wire and DG wire on PTC switching module

C1912M.

Measure the resistance between the R wire and W wire on PTC

switching module C1912M.

Are the resistances between 65 and 140 ohms?

E12 CHECK HIGH-VOLTAGE POWER TO PTC SWITCHING

MODULE

Yes =

GO to E17.

WARNING: The following test steps contain high-voltage

procedures. High-voltage insulated safety gloves and face shield must

be worn when carrying out the following steps. Failure to follow this

warning may result in severe personal injury or death.

Disconnect HVPDB PTC switching module high-voltage C1920.

Reinstall the HVPDB cover.

No =

GO to E13.

Reconnect the 12-volt auxiliary battery negative cable.

With key ON, measure the voltage between circuit 3104 (DB wire) and

circuit 3105 (W wire) on HVPDB PTC switching module C1920F.

Is the voltage greater than 300 volts?

E13 CHECK HIGH-VOLTAGE FUSE

With key OFF, disconnect the 12-volt auxiliary battery negative cable.

Yes =

REPLACE the 25A PTC

HTR fuse. GO to E14.

Disconnect high-voltage auxiliary load in-line C1935 on the traction

No =

REPLACE the HVPDB.

battery support tray.

REFER to

Section 414-03A

Disconnect all HVPDB high-voltage connectors.

or

Section 414-03B

.

Disconnect power steering assembly high-voltage C1895.

Measure the resistance of the 25A PTC HTR fuse.

Is the resistance greater than 1,000 ohms?

E14 CHECK PTC SWITCHING MODULE FOR SHORT

Measure the resistance between circuit 3104 (DB wire) and circuit 3105

Yes =

REPLACE the PTC

(W wire) on HVPDB PTC switching module C1920M.

switching module.

Is the resistance less than 30 ohms?

No =

GO to E15.

E15 CHECK HVPDB FOR SHORT

Measure the resistance between circuit 3104 (DB wire) and circuit 3105

Yes =

GO to E16.

(W wire) on HVPDB PTC switching module C1920F.

(Continued)

412-02-14

412-02-14

Heating and Ventilation

DIAGNOSIS AND TESTING (Continued)

PINPOINT TEST E: DTC C1776 HEATER SYSTEM FAILURE

TEST STEP

ACTION TO TAKE

Is the resistance greater than 10,000 ohms?

No =

REPLACE the HVPDB.

REFER to

Section 414-03A

or

Section 414-03B

.

E16 CHECK SYSTEM

With key OFF, reconnect all component connectors that were

Yes =

REPLACE the PTC

disconnected.

switching module.

REPLACE the 25A PTC

HTR fuse. REFER to

Section 414-03A

or

Section 414-03B

.

With key ON, set the mode select knob to the PANEL/FLOOR position,

No =

System OK.

the temperature control knob to the full warm position, and the blower

control knob to the HIGH speed position.

Does the 25A PTC HTR high-voltage fuse fail again?

E17 INSPECT PTC HEATER CORES

Remove the PTC heater core and check for contaminants (excessive

Yes =

REPLACE the PTC

moisture or debris) on the heater core.

switching module.

Is the heater core clear of contaminants?

No =

REMOVE the contaminants.

If necessary, REPLACE the

PTC heater core.

PINPOINT TEST F: DTC C1779 BLOWER SWITCH FAILURE

TEST STEP

ACTION TO TAKE

F1 CHECK BLOWER SWITCH STATUS

With key ON, monitor the interface adapter assembly (IAA) module PID

Yes =

System OK. CHECK wiring

BLOWER while rotating the blower control knob through all the blower

for intermittent connections.

speed positions.

Does the BLOWER PID agree with all the blower speed positions?

No =

GO to F2.

F2 CHECK BLOWER SWITCH INPUT VOLTAGE REFERENCES

Connect 104-Pin Breakout Box (BOB) to IAA module and IAA module

Yes =

GO to F7.

C1945.

With key ON, measure the voltage between BOB pins 60, 61, 62 and

No =

GO to F3.

ground (BOB pin 80).

Do the voltages fluctuate between 0 and 2.8 volts?

F3 CHECK GROUND TO BLOWER SWITCH

With key OFF, disconnect blower switch C232 and measure the

Yes =

GO to F4.

resistance between the BK wire on blower switch C232 and ground.

Is the resistance less than 5 ohms?

No =

REPAIR the BK wire.

F4 CHECK CIRCUITS 751 (DB/W), 752 (Y/R), AND 754 (LG/W) FOR

OPEN(S)

With key OFF, disconnect IAA module from BOB; leave BOB

Yes =

GO to F5.

connected to IAA module C1945.

With key OFF, measure the resistance of the DB/W wire between blower No =

REPAIR the wire(s) in

switch C232 and BOB pin 62.

question.

With key OFF, measure the resistance of the Y/R wire between blower

switch C232 and BOB pin 61.

With key OFF, measure the resistance of the LG/W wire between blower

switch C232 and BOB pin 60.

Are the resistances less than 5 ohms?

F5 CHECK CIRCUITS 751 (DB/W), 752 (Y/R), AND 754 (LG/W) FOR

SHORT(S) TO GROUND

(Continued)

412-02-15

412-02-15

Heating and Ventilation

DIAGNOSIS AND TESTING (Continued)

PINPOINT TEST F: DTC C1779 BLOWER SWITCH FAILURE

TEST STEP

ACTION TO TAKE

With key OFF, measure the resistance between BOB pins 60, 61, 62 and

Yes =

GO to F6.

ground (BOB pin 80).

Are the resistances greater than 10,000 ohms?

No =

REPAIR the wire(s) in

question.

F6 CHECK CIRCUITS 751 (DB/W), 752 (Y/R), AND 754 (LG/W) FOR

SHORT(S) TO POWER

With key ON, measure the voltage between BOB pins 60, 61, 62 and

Yes =

REPAIR the wire(s) in

ground (BOB pin 80).

question.

Are any of the voltages greater than 0 volts?

No =

REPLACE the IAA module.

REFER to

Section 412-04

.

F7 CHECK BLOWER SWITCH

With key OFF, disconnect blower switch C232 and check the continuity

Yes =

REPLACE the IAA module.

of the blower switch by measuring the resistance between the circuit 57

REFER to

Section 412-04

.

(BK wire) terminal and the indicated terminals on the blower switch.

Compare the readings to the values below:

Low Blower Position

No =

REPLACE the blower

switch.

— Circuit 751 (DB/W wire) terminal = Open
— Circuit 752 (Y/R wire) terminal = Open
— Circuit 754 (LG/W wire) terminal = Open
Medium Blower Position
— Circuit 751 (DB/W wire) terminal = Closed
— Circuit 752 (Y/R wire) terminal = Open
— Circuit 754 (LG/W wire) terminal = Open
Medium-High Blower Position
— Circuit 751 (DB/W wire) terminal = Closed
— Circuit 752 (Y/R wire) terminal = Closed
— Circuit 754 (LG/W wire) terminal = Open
High Blower Position
— Circuit 751 (DB/W wire) terminal = Open
— Circuit 752 (Y/R wire) terminal = Closed
— Circuit 754 (LG/W wire) terminal = Closed

Is the blower switch OK?

PINPOINT TEST G: DTC C1780 TEMPERATURE SELECT FAILURE

TEST STEP

ACTION TO TAKE

G1 CHECK TEMPERATURE CONTROL OPERATION

With key ON, monitor the interface adapter assembly (IAA) module PID

Yes =

System OK. CHECK wiring

SET TMP while rotating the temperature control knob from the full

for intermittent connections.

cool position to the full warm position.

Does the SET TMP PID indicate approximately 98% at the full

No =

GO to G2.

cool position and approximately 1% at the full warm position?

G2 CHECK TEMPERATURE CONTROL VOLTAGE REFERENCE

With key OFF, disconnect temperature control C231.

Yes =

GO to G5.

With key ON, measure the voltage between the LG/O wire and Y/LG

No =

GO to G3.

wire on temperature control C231.

Is the voltage between 4.8 and 5.2 volts?

G3 CHECK CIRCUITS 3057 (LG/O) AND 3059 (Y/LG) FOR OPEN(S)

Connect 104-Pin Breakout Box (BOB) to IAA module C1945; leave IAA Yes =

GO to G4.

module disconnected.

(Continued)

412-02-16

412-02-16

Heating and Ventilation

DIAGNOSIS AND TESTING (Continued)

PINPOINT TEST G: DTC C1780 TEMPERATURE SELECT FAILURE

TEST STEP

ACTION TO TAKE

With key OFF, measure the resistance of the LG/O wire between

No =

REPAIR the wire(s) in

temperature control C231 and BOB pin 84.

question.

With key OFF, measure the resistance of the Y/LG wire between

temperature control C231 and BOB pin 71.

Are the resistances less than 5 ohms?

G4 CHECK CIRCUIT 3057 (LG/O) FOR SHORT TO GROUND

With key OFF, measure the resistance between BOB pin 84 and ground

Yes =

REPLACE the IAA module.

(BOB pin 80).

REFER to

Section 412-04

.

Is the resistance greater than 10,000 ohms?

No =

REPAIR the LG/O wire.

G5 CHECK CIRCUIT 3058 (LG/R) FOR OPEN

Connect 104-Pin Breakout Box (BOB) to IAA module C1945; leave IAA Yes =

GO to G6.

module disconnected.

With key OFF, measure the resistance of the LG/R wire between pin 2

No =

REPAIR the LG/R wire.

on temperature control C231 and BOB pin 50.

Is the resistance less than 5 ohms?

G6 CHECK CIRCUIT 3058 (LG/R) FOR SHORT TO GROUND

With key OFF, measure the resistance between BOB pin 50 and ground

Yes =

GO to G7.

(BOB pin 80).

Is the resistance greater than 10,000 ohms?

No =

REPAIR the LG/R wire.

G7 CHECK CIRCUIT 3058 (LG/R) FOR SHORT TO POWER

With key ON, measure the voltage between BOB pin 50 and ground

Yes =

REPAIR the LG/R wire.

(BOB pin 80).

Is the voltage greater than 0 volts?

No =

GO to G8.

G8 CHECK RESISTANCE OF TEMPERATURE CONTROL

POTENTIOMETER

With key OFF, reconnect temperature control C231.

Yes =

REPLACE the IAA module.

REFER to

Section 412-04

.

With key OFF, measure the resistance between the BOB pins 50 and 84

No =

REPLACE the temperature

with the temperature control knob in the indicated positions and verify

control potentiometer.

the resistances below:

— Full cool = 90-300 ohms
— Midscale = 2,000-3,000 ohms
— Full warm = 4,000-5,000 ohms

Are the resistances OK?

PINPOINT TEST H: DTC B1857 CLIMATE CONTROL ON/OFF SWITCH FAILURE

TEST STEP

ACTION TO TAKE

H1 IDENTIFY VACUUM PUMP SYMPTOM

With key ON, set the mode select knob to the OFF and PANEL/FLOOR Yes = GO to

Pinpoint Test Q.

positions and listen for the vacuum pump cycling on and off

continuously.

Does the vacuum pump cycle on and off continuously?

No =

GO to H2.

H2 IDENTIFY VEHICLE OPTION

Identify the vehicle option (A/C or non-A/C).

Yes =

GO to H3.

Is the vehicle equipped with A/C?

No =

GO to H4.

H3 CARRY OUT ON-DEMAND SELF-TEST IN A/C MODE

With key ON, set the mode select knob to the A/C position and carry out Yes =

GO to H5.

the on-demand self-test for the interface adapter assembly (IAA) module.

Does DTC B1857 Climate Control On/Off Switch Failure occur?

No =

GO to H4.

(Continued)