Ford F150 Pickup. Instruction — part 1152
Fig. 3: View Of Coalescer/Filter Assembly
Courtesy of FORD MOTOR CO.
Typical Vent Stack Installation
Refer to the following illustration for a typical vent stack installation.
2003 Ford Pickup F150
2003 GENERAL INFORMATION Fuel System - General Information - Natural Gas - F150 Pickup
Fig. 4: Typical Vent Stack
Courtesy of FORD MOTOR CO.
DIAGNOSIS & TESTING
2003 Ford Pickup F150
2003 GENERAL INFORMATION Fuel System - General Information - Natural Gas - F150 Pickup
FUEL SYSTEM
Refer to appropriate SELF-DIAGNOSTICS article .
GENERAL PROCEDURES
DRAINING - COALESCER/FILTER
1. Perform the fuel line venting procedure; refer to FUEL LINE EVACUATION .
2. Place a container under the coalescer/filter assembly.
NOTE:
Hold the coalescer body with a wrench on the flats, to prevent loosening
of the filter housing.
2003 Ford Pickup F150
2003 GENERAL INFORMATION Fuel System - General Information - Natural Gas - F150 Pickup
Fig. 5: Locating Coalescer/Filter Assembly Drain Plug
Courtesy of FORD MOTOR CO.
3. Slowly loosen the coalescer/filter assembly drain plug, to vent the system of any residual fuel pressure.
4. Remove the coalescer/filter assembly drain plug and allow all liquid to drain.
5. Install the coalescer/filter assembly drain plug and tighten to specifications.
Fig. 6: Installing Coalescer/Filter Assembly Drain Plug
Courtesy of FORD MOTOR CO.
6. Perform the fuel system leak test procedure; refer to FUEL SYSTEM LEAK TEST .
SPRING LOCK COUPLINGS
Special Tool(s)
2003 Ford Pickup F150
2003 GENERAL INFORMATION Fuel System - General Information - Natural Gas - F150 Pickup
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.