Ford F150 Pickup. Instruction — part 1506


Connect scan tool to Data Link Connector (DLC). Place gearshift lever in "P" position. Start engine and
allow to idle. Using scan tool, access TANKPR PID from NGVM PID/DATA MONITOR & RECORD
menu. Record TANKPR PID value. Using scan tool, access FRP PID from PCM PID/DATA MONITOR
& RECORD menu. Record FRP PID value. Locate approximate TANKPR PID value and determine
PCM inferred pressure using PCM INFERRED PRESSURE SPECIFICATIONS table. If PCM
inferred pressure is plus or minus 22 psi of FRP PID value, no concern is indicated at this time. Service
any other DTCs that are present. If PCM inferred pressure is not plus or minus 22 psi of FRP PID value,
go to next step (for DTC P1180), or replace fuel pressure regulator (for DTC P1181).

PCM INFERRED PRESSURE SPECIFICATIONS

19) Check Fuel Filter For Water Or Other Contamination

Disassemble fuel filter and check for water or any other contamination. If contamination is present, clean
contaminants from filter housing and replace filter. If no contamination is present, go to next step.

TANKPR PID Value - kPa

PCM Inferred Pressure - psi

2000

109

3000

108.4

4000

106.9

5000

106.5

6000

106

7000

105.6

8000

105

9000

104.5

10,000

103.4

11,000

103

12,000

102.5

13,000

102.3

14,000

101.8

16,000

100.8

17,000

99.8

18,000

99.3

19,000

99

20,000

98.5

21,000

97.5

22,000

97.3

23,000

96.3

24,000

96

26,000

96

28,000

95.5

30,000

94

2003 Ford Pickup F150

2003 ENGINE PERFORMANCE Self-Diagnostics - CNG, Flex-Fuel & Gasoline

20) Check Fuel Line For Restriction

Visually inspect all fuel lines for damage which may lead to restrictions and leakage. Repair as necessary.
If all fuel lines are okay, go to next step.

21) Determine Cause Of No Start

Disconnect FRP Sensor electrical connector. Attempt to start vehicle. If engine will now start and run,
replace fuel rail pressure sensor. If engine will not start and run, replace fuel pressure regulator.

TEST HC: GASOLINE FUEL DELIVERY SYSTEM

Diagnostic Aids

Perform this test when directed by QUICK TEST or if directed by other test procedures. This test is used to
diagnose:

z

Chassis Components

z

Engine Vacuum Systems

z

Fuel Pressure

z

Fuel Filter

z

Fuel Return

z

Fuel Supply

z

Fuel Injector

Testing

1) For Continuous Memory Only DTC P0148: Check System Integrity
This DTC indicates at least one bank lean at wide open throttle. Possible causes are:

z

Severely restricted fuel filter.

z

Severely restricted fuel supply line.

NOTE:

After each service or repair procedure has been completed, reconnect all
components. Clear DTCs and repeat QUICK TEST procedures to ensure all EEC-
V systems are working properly and DTCs are no longer present.

NOTE:

For specific vehicle fuel system identification, see Fig. 167.

WARNING:

Always refer to safety procedures to reduce possibility of injury. See
FUEL SYSTEM SAFETY PRECAUTIONS.

NOTE:

For additional testing information, see DIAGNOSTIC AIDS.

2003 Ford Pickup F150

2003 ENGINE PERFORMANCE Self-Diagnostics - CNG, Flex-Fuel & Gasoline

Visually inspect complete fuel delivery system for damage. Check fuel lines, connections, relays, fuel
tank, fuel pump, fuel pressure regulator, fuel pulse damper and fuel injector areas for leaks. Check for
looseness, cracks, kinks, pinching, or abrasion caused by a collision or mishandling. Visually inspect
electrical harness and connectors for loose pins, corrosion, abrasion, or other damage from collision or
mishandling. Check electrical connectors for proper mating. Ensure customer has followed vehicle
maintenance schedule. Ensure Inertia Fuel Shutoff (IFS) switch is reset. Ensure battery is fully charged
(12.5 volts or more) and that fuses are okay. Ensure fuel level in tank is sufficient. Repair as necessary. If
no faults are found, go to next step.

2) Check Voltage At Fuel Pump Harness Connector

Connect battery charger to battery. Ensure IFS is reset. If it is not reset, perform INERTIA FUEL
SHUTOFF SWITCH RESET PROCEDURE
under GASOLINE SYSTEM under FUEL SYSTEM
SAFETY PRECAUTIONS. Connect scan tool to Data Link Connector (DLC). Disconnect fuel pump
harness connector at fuel pump. Turn ignition switch to ON position. Connect DVOM between fuel pump
PWR and GND circuits at fuel pump harness connector. See WIRING DIAGRAMS. Using scan tool,
access OUTPUT TEST MODE. See

OUTPUT TEST MODE

under ADDITIONAL SYSTEM

FUNCTIONS. Command fuel pump ON and monitor DVOM voltage. If voltage is more than 12.5 volts,
turn ignition switch to OFF position, exit OUTPUT TEST MODE, reconnect fuel pump harness
connector and go to next step. If voltage is 12.5 volts or less, go to TEST KB, step 70) (ERFS vehicles),
or check for open or shorts in fuel pump PWR or GND circuits (all others). See Fig. 167.

3) Check Fuel Filter For Proper Maintenance

Check last time fuel filter was replaced. If fuel filter has been serviced regularly (within 30,000 miles), go
to next step. If fuel filter has not been serviced regularly, replace fuel filter and go to next step.

4) Check Fuel Pressure
Turn ignition switch to OFF position. Release fuel system pressure. See FUEL SYSTEM PRESSURE
RELEASE procedure under FUEL SYSTEMS in appropriate REMOVAL & INSTALLATION article.
Install fuel pressure gauge supplied in Kit (134-00114) to Schrader valve located on fuel rail. Turn
ignition switch to ON position. Using scan tool, access OUTPUT TEST MODE. See OUTPUT TEST
MODE
under ADDITIONAL SYSTEM FUNCTIONS. Command fuel pump ON.

Record fuel pressure. Compare fuel pressure to specification. See Fig. 167. If fuel pressure is within
specification on vehicles with returnable fuel system, go to next step. If fuel pressure is within
specification on vehicles with ERFS, go to step 6). If fuel pressure is within specification on vehicles with
MRFS, go to step 12). See Fig. 167. If fuel pressure is not within specification, proceed as follows:

z

If fuel pressure is more than specified on vehicles with MRFS, replace fuel pressure regulator in
fuel tank. Recheck fuel pressure.

z

If fuel pressure is less than specified on vehicles with MRFS, go to step 6).

WARNING:

Always refer to safety procedures to reduce possibility of injury. See
FUEL SYSTEM SAFETY PRECAUTIONS.

NOTE:

When energized by scan tool, fuel pump will operate for only 8 seconds.

2003 Ford Pickup F150

2003 ENGINE PERFORMANCE Self-Diagnostics - CNG, Flex-Fuel & Gasoline

z

If fuel pressure is more than specified on vehicles with ERFS, repeat QUICK TEST. Other DTCs
should be present if fuel pressure concern exists.

z

If fuel pressure is more than specified on all other vehicles with returnable fuel system, go to step
10).

z

If fuel pressure is less than specified on all other vehicles with ERFS and returnable fuel system, go
to step 13).

5) Check Fuel Pressure Leakdown
With fuel pressure gauge supplied in Kit (134-00114) connected to Schrader valve located on fuel rail,
turn ignition switch to ON position. Using scan tool, access OUTPUT TEST MODE. See OUTPUT
TEST MODE
under ADDITIONAL SYSTEM FUNCTIONS. Command fuel pump ON. Record
maximum fuel pressure. Turn ignition switch to OFF position. If fuel pressure remains within 5 psi (34
kPa) of maximum fuel pressure for one minute after fuel pump turns off, go to step 7). If fuel pressure
does not remain within 5 psi (34 kPa) of maximum fuel pressure for one minute after fuel pump turns off,
go to next step.

6) Check Pressure Regulator & Pulse Damper Diaphragm

With fuel pressure gauge supplied in Kit (134-00114) connected to Schrader valve located on fuel rail,
start engine and allow to idle for 10 seconds. Turn ignition switch to OFF position and wait 10 seconds.
Start engine again and allow to idle for 10 seconds. Turn ignition switch to OFF position. Disconnect and
inspect vacuum hose from fuel pressure regulator or pulse damper. If hose is wet with fuel, replace pulse
damper (vehicles with MRFS), or fuel pressure regulator (all others). If hose is dry, go to step 13)
(vehicles with MRFS), or go to step 12) (all others).

7) Check Fuel Pressure While Test Driving Vehicle

Ensure fuel pressure gauge supplied in Kit (134-00114) is connected to Schrader valve located on fuel
rail. Disconnect and plug fuel pressure regulator vacuum hose. Drive vehicle with heavy accelerations
while monitoring fuel pressure gauge reading. If fuel pressure reading holds steady within 3 psi (21 kPa)
during road test, go to next step. If fuel pressure reading does not hold steady within 3 psi (21 kPa) during
road test, go to step 13).

8) Check Fuel Pressure Regulator Response

Ensure fuel pressure gauge supplied in Kit (134-00114) is connected to Schrader valve located on fuel
rail. Install vacuum gauge to intake manifold. Ensure fuel pressure and vacuum gauges can be seen by
vehicle operator. Road test vehicle, accelerating and decelerating engine speed while monitoring fuel
pressure and vacuum gauge readings. Fuel pressure gauge reading should increase as vacuum gauge
reading decreases, and decrease as vacuum gauge reading increases. If gauge readings do not operate as
specified, go to next step. If gauge readings operate as specified, fuel system is functioning properly.
Diagnose by symptom. See SYMPTOMS in TROUBLE SHOOTING - NO CODES - CNG, FLEX-
FUEL & GASOLINE.

WARNING:

Always refer to safety procedures to reduce possibility of injury. See
FUEL SYSTEM SAFETY PRECAUTIONS.

2003 Ford Pickup F150

2003 ENGINE PERFORMANCE Self-Diagnostics - CNG, Flex-Fuel & Gasoline

Была ли эта страница вам полезна?
Да!Нет
5 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности