Chery Tiggo. Manual — part 372
1 - Condenser
2 - Compressor
3 - Suction Line
4 - Liquid Line
5 - Accumulator
6 - Refrigerant Pressure Sensor
7 - Expansion Valve
8 - HVAC Housing
9 - HVAC Control Panel
GENERAL INFORMATION
LTSM130021
13
Operation
Outside fresh air enters the vehicle through the cowl top opening at the base of the windshield, and passes through
a plenum chamber to the HVAC housing. Air flow can be adjusted by the blower motor speed switch on the A/C
heater control panel. The fresh air then travels through the evaporator and the heater core then out into the vehicle
through the side and floor vents. It is important to keep the air intake openings clear of debris such as leaf particles
which are small enough to pass through the cowl plenum screen and can accumulate within the HVAC housing. The
A/C compressor can be engaged by pressing the A/C (snowflake) button on the A/C-Heater control panel. It will
automatically engage when the mode control is set in any Mix to Defrost position. This will remove heat and humidity
from the air before it is directed through or around the heater core. The mode control on the A/C-Heater control panel
is used to direct the conditioned air to the selected system outlets.
Specifications
Torque Specifications
DESCRIPTION
TORQUE (N·m)
All General Service Screw
2
Condenser Bolts
6
Evaporator Bolts
4
GENERAL INFORMATION
LTSM130020T
DESCRIPTION
TORQUE (N·m)
Expansion Valve Bolts
10
Pipeline Stent
4
Refrigerant Lines To A/C Accumulator
6
Refrigerant Lines To A/C Compressor Bolt
30
Refrigerant Lines
10
Refrigerant Lines To A/C Evaporator Bolt
25
A/C Pressure Specifications
AMBIENT TEMPERATURE
A/C HIGH SIDE PRESSURE
A/C LOW SIDE PRESSURE
15.5°C
8.4 - 11.9 kgf/cm
2
120 - 170 psi
1.9 - 2.1 kgf/cm
2
28 - 31 psi
21.1°C
10.5 - 17.5 kgf/cm
2
150 - 250 psi
1.9 - 2.1 kgf/cm
2
28 - 31 psi
26.6°C
12.6 - 19.3 kgf/cm
2
180 - 275 psi
1.9 - 2.1 kgf/cm
2
28 - 31 psi
32.2°C
14.0 - 21.8 kgf/cm
2
200 - 310 psi
1.9 - 2.1 kgf/cm
2
28 - 31 psi
37.7°C
16.1 - 23 kgf/cm
2
230 - 330 psi
1.9 - 2.4 kgf/cm
2
28 - 35 psi
43.3°C
18.9 - 25.3 kgf/cm
2
270 - 360 psi
1.9 - 2.6 kgf/cm
2
28 - 38 psi
AMBIENT
TEMPERATURE
VEHICLE SPEED
A/C HIGH SIDE
PRESSURE
A/C LOW SIDE
PRESSURE
35°C
Idle Speed
1.4 - 1.8 MPa
0.26 - 0.33 MPa
30°C
Idle Speed
1.3 - 1.8 MPa
0.26 - 0.33 MPa
A/C Refrigerant Charge Specifications
DESCRIPTION
CAPACITY (g)
R-134a Refrigerant
700
Special Tools
Digital Multimeter
Fluke 15B & 17B
GENERAL INFORMATION
13
Electrical Schematics
Air Conditioner Control - 1.6L & 1.8L (Page 1 of 3)
GENERAL INFORMATION
LTSMW130004T
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.