Chery S11 / Chery QQ. Manual — part 77
Chery QQ Service Manual
should be dropped on the seat surface of the connecting nut and the O-shape of seal
ring.
(
4)when the joint is screwed or unscrewed, two wrenches should be used, one is for
tightening, the other for supporting.
(
5)inlet connecting pipe of the stock solution drier should be connected with the
outlet connecting pipe of the condensator.
(
6)tighten the pipe socket nut according to the following required tightening torque.
Tigntening torque for connecting nut:8 ㎜ pipe:12-15N·m
(
1.2-1.5kg-m.8.6-11.01b-ft)1/2 inch pipe:20-25N·m
(
2.0-2.5kg-m.14.5-18.0Ib-ft)5/8 inch pipe:30-35N·m
(
3.0-3.5kg-m.22.0-25.3Ib-ft)
(
7)water drain hoses should be arranged in the way that the drained water should
not drop on the parts of the car.
3. Recovery of the refrigerant
Refrigerant recovery and regenerative unit must be used when refrigerant is
discharged from air conditioning system. Directly discharging refrigerant HFC-134a
(
R-134a)into atmosphere will bring serious effects on environment.
Note: when using recovery and regenerative unit, you must follow the operating
instruction of the device.
4. Management of refrigerant
(
1)when dealing with refrigerant, you must take the safety goggles to protect your
eyes.
(
2)avoid to touch liquid refrigerant directly.
(
3)the refrigerant tank should not be heated over to 40℃.
(
4)it is not allowed to discharge the refrigerant to the atmosphere.
(
5)it is not allowed to splash the refrigerant to the polishing metal surface because
the corrosive combination of refrigerant and water can make the polishing metal
surface dislustered (including chromium-coated part).
(
6)after refrigerant of the system is recovered, lost oil in compressor must be
147
Chery QQ Service Manual
determined and make-up the same amout of oil.
Warning: if refrigerant HFC-134a(R-134a)splashes into eyes, you should go to
hospital for treatment quickly.
It is not permissible to wipe your hurted eyes, but to wash them with a large amount
of clean cold water to make the temperature of your hurted parts rise to the freezing
point.
Must go to see doctors or ophthalmology professors for treatment. If HFC-134a
(
R-134a)liquid splashes on skin, the hurt should be treated in the same way as the
frostbite treatment.
Section 10 Check Refrigerant System with Manifold
Measurement Unit
I. This method serves to confirm the fault position with manifold
measurement unit
Read the manifold pressure meter when the system reaches the following status:
(
1)set the switch on the circular position , the supplying air temperature is 30-35
℃
(
2)the engine runs in 1500r/min.
(
3)set the
rotate speed control switch of supply fan at high speed.
(
4)set the temperature control switch at the position where the cold air is most
sufficient.
Note:It should be indicated that the readings of the meter will change slightly
depending on the environment termperature.
1. Refrigeration system works normally
Reading on meter:
Low pressure side:0.15-0.25
MPa
(
1.5-2.5kg/cm
2
)
148
Chery QQ Service Manual
High pressure side:1.37-1.57
MPa
(
14-16kg/cm
2
)
2.
Water vapor exists in the refrigeration system.
Symptom
:
discontinuous cold air to no cold air.
Fault symptom of
refrigeration
system
Possible reasons
Fault diagonosis
Troubleshooting
action
When running, pressure The vapor
entering
Drier is in
(
1)replace the stock
149
Chery QQ Service Manual
at low pressure side
sometimes is normal,
but sometimes vacuum.
the refrigeration
system ices in the
spraying hole of
the expansion valve
to make the
circulation stop
temperarily, but
after the ice melts,
it can work
normally.
oversaturation
↓
Water vapor ices at
the spraying hole of
the expansion valve to
block circulation of
refrigerant.
solution drier
(2) evacuate air
repeatly to eliminate
the vapor in the
circulation.
(3) charge appropriate
amount of new
refrigerant.
3. Insufficient refrigerant
Symptom:insufficient cold air
Fault symptom of
refrigeration system
Possible reasons
Fault diagonosis Trouble-shooting
action
Low pressure at both
low pressure side and
high side
bad cooling Performance
air leakage at
somewhere in
refrigeration
system
Insufficient
refrigerant in system
↓
Refrigerant leakage
(
1)using air leakage detector to
check where there is leakage.
If necessary, repair it.
(
2)charge appropriate amount
of refrigerant.
(
3)if the reading is about 0
after connecting the meter, the
leakage positions should be
150