Chery B11. Manual — part 125
Chery B11 Service Manual
Air Conditioner-23
(737mmHg), and then vacuumize 15 min again so as to remove the air entering into the
system together with the oils. In this case, the refrigeration oils are in the high-pressure side,
and the oils will return back to the compressor after the operation of the system.
Refrigeration oil charge
Specified quantity: SP10 model, 150ml. It is unnecessary to charge the refrigeration oil into the
newly-mounted A/C system, and it is required to complement some refrigeration oils only when a
certain part is needed to repair or when the vehicle is driven a specified mileage. The quantity of
implementing oil required when replacing parts is as follows:
Evaporator and condenser: 30ml. Drier: 20ml. and pipe: 10ml.
Chery B11 Service Manual
Air Conditioner-24
Section 14 Leak Check of Refrigeration System
Three effective methods can be used to check the air tightness of refrigeration system: check with
electronic leak detector, soap solution and halogen leak detector.
(I)
Check with Electronic Leak Detector
As shown in the figure, connect the power supply connector 2 of electronic leak detector 1 to the
power supply, and move probe 3 slowly (30 mm/s), which should be placed 3 mm away from the
check point. And if any alarming sound is emitted, it means there is a leak phenomenon occurred
at that place. If the leakage occurs at the joints of refrigeration pipes, the relevant O-rings shall be
replaced.
(II) Check with Soap Solution
Apply the soap solution to the possible leak
position.
Observe whether air bubbles appear. If there are air
bubbles, it indicates a leaking accident occurs.
Check with Electronic Leak Detector.
(III) Check with Halogen Leak Detector
As shown in the right figure, the halogen leak
detector is in principle a propane blowtorch.
The inspection procedure is described below:
(1) Check the liquid propane capacity in the
reservoir.
(2) Tighten the propane reservoir 16 to the leak
detector.
(3) Insert a lighting match into lighting device 9,
and then slowly turn the adjusting handle 14 in
the counterclockwise direction till the torch is
lit.
1-Electronic leak detector. 2-Power supply connector.
3-Probe
Check with Halogen Leak Detector
1-Upper limit of flame. 2-Lower limit of flame. 3-Suck
pipe. 4-Rough filter. 5-Cover. 6-Combustion chamber.
7-Flame ring. 8-Screw for flame ring. 9-Lighting device.
10-Spraying hole. 11-Base. 12-Nozzle. 13-Valve body.
14-Adjusting handle. 15-Reservior nozzle. 16-Propane
reservoir
Chery B11 Service Manual
Air Conditioner-25
(4)
Adjust the flame to smallest. The smaller the flame, the more sensitive to the leak of
refrigerant.
(5) Move suck pipe 3 to the possible leak position.
(6)
Observe the change of flame color. The flame has no color if there is no leakage. The flame
is tint green if there is very small leakage or be blue if there is relatively big leakage, and it
will become purple if there is too much leakage.
Chery B11 Service Manual
Air Conditioner-26
Section 15 Driven Belt Check
Check the driven belt tension
1
Check the installation of the driven belt
Check whether the belt is correctly engaged with its
pulley, shown in the figure.
2
Check the tension of the belt
Tension of driven belt under 98N (10kg/22.0P)
Check value: 7.0 to 9.5 mm
Adjusting value:
New belt: 6.0~7.0mm
Old belt: 8.0~9.0mm
● “New belt” means a belt that is used less than 5
min on the engine operating.
● “Old belt” means a belt that is used no less than 5
min on the engine operating.
● After the installation of driven belt, check if it is
installed correctly as described above.
Right
Wrong