Chery B11. Manual — part 122
Chery B11 Service Manual
Air Conditioner-11
Section 8 Failures and Troubleshooting Analysis Table
The regular failures and its causes of A/C unit are shown in the table below.
Phenomenon
Possible Cause
Method of Troubleshooting
Warm air no hot
(1) Water pipe fall off
(2) Hot water valve failure
(3) Water pipe jam
(4) Low blower speed
(5) Blower no rotation
(6) Temperature damper not reset
(1) Remount the water pipe
(2) Replace the hot water valve
(3) Dredge the water pipe or replace the radiator
(4) Check the series resistance of blower
(5) Check the A/C motor and its circuit
(6) Adjust the temperature damper
Cooling
inadequate
or airflow insufficient
(1) Poor battery connection
(2) Air channel broken
(3) Dust filter jam
(4) Evaporator frosted
(5) Blower motor, relay or its circuit failure
(6) A/C unit blown fuse broken
(7) Refrigeration system with outside air
leakage
(8) Central damper solenoid valve or fresh
air/recirculation air vacuum valve
damaged
(1) Check the battery voltage and connector
(2) Reconnect the air channel
(3) Rinse or replace the dust filter
(4) Check the anti-frosting switch and A/C relay
(5) Check blower motor, relay and its circuit
(6) Replace the blown fuse
(7) Vacuumize, and charge the refrigerant again
(8) Check or replace the central damper solenoid
valve or fresh air/recirculation air vacuum valve
Cooling
inadequate
or airflow insufficient
(9) Refrigerant insufficient
(10) Refrigerant overabundant
(11) Refrigeration system with air
(12) Condenser radiating
pin jam or
distortion
(13) Radiator fan failure
(14) Refrigeration system with moisture
(15) Throttle pipe (CCOT valve) jam
(16) Low compressor speed
(17) Compressor no operation
(18) High-pressure pipe or components jam
or flattened
(9) Find out the leaking location, and charge
refrigerant
(10) Drain the appropriate refrigerant
(11) Fully vacuumize, and charge the refrigerant
again
(12) Rinse or replace the condenser
(13) Check fan motor and its circuit, and remove the
failure
(14) Replace the container, and vacuumize repeatly
(15) Replace the throttle pipe
(16) Check and adjust the driving V belt
(17) Check the compressor, electromagnetic clutch
and high- and low-pressure protection switches,
and remove the failures
(18) Rinse or replace the components
Compressor
abnormal noise
(1) Electromagnetic clutch slip or damaged
(2) Refrigerant insufficient or excessive
(3) Compressor bearing loose or worn
seriously
(4) Compressor refrigerating oil level low
(5) Compressor internal worn or damaged
(1) Adjust the clearance of electromagnetic clutch,
and repair the coil of electromagnetic clutch
(2) Charge the refrigerant as per the specified
(3) Replace the compressor bearing
(4) Add the compressor refrigerating oil
(5) Replace the compressor components or assy.
Chery B11 Service Manual
Air Conditioner-12
Section 9 Check Refrigeration Device by Using Manifold
Pressure Gauge Kit
This is a method to check the location of failure with the help of manifold pressure gauge kit.
Under the following conditions, the reading of manifold pressure gauge is recorded:
(a)
When the switch is turned to “RECIRC” (air recirculation), the temperature of air inlet is 30
to 35℃ (86 to 95F℃).
(b) The engine speed is 2,000 rpm.
(c) The blower fan control switch is turned to “HI-SPEED” position.
(d) The temperature controlled switch is turned to “COLD” position.
Hint: Take care that the value displayed on the instrument may change gently with the various
ambient temperatures.
WARNING:
● Take care to recycle the refrigerant before the components removal from the refrigerant pipe
and the air drainage .
● The air must be drained after the components are installed on the refrigerant pipe, and the
appropriate purified refrigerant shall be charged.
No.
Manifold Pressure Gauge Reading:
KPa (Kgf/cm
2
, lb/sq.in.)
Condition
Possible Cause
Method of
Troubleshooting
1
LO (Low-Pressure): 147 to 196
(1.5 to2.0, 21 to 28)
HI (High-Pressure): 1,422 to 1,471
(14.5 to 15.0, 206 to 213)
Cold air normal
Refrigeration device
operation normal
Chery B11 Service Manual
Air Conditioner-13
2
During the course of operation, the pressure of
low-pressure end is vacuum, and, sometimes, normal
Intermittent
refrigeration,
and
then
refrigeration
failure
Refrigeration device
with moisture
(1) Replace
the
container
(2) Remove
the
moisture from the
refrigeration
device
via
the
repeat air drainage
WARNING:
● Take care to recycle the refrigerant before the components removal from the refrigerant pipe
and the air drainage.
● The air must be drained after the components are installed on the refrigerant pipe, and the
appropriate purified refrigerant shall be charged.
No.
Manifold Pressure Gauge Reading:
KPa (Kgf/cm
2
, lb/sq.in.)
Condition
Possible Cause
Method of
Troubleshooting
● Refrigeration insufficient
● Air bubble visible from
the sight glass
Refrigerant insufficient
(1) Apply the leak detector
to detect the leaking
condition, and repair it
as required
(2) Charge the refrigerant
till that the air bubbles
disappear fully
3
The pressures of both the low-pressure end
and high-pressure end are low
● Refrigeration insufficient
● Pipe from the container to
the refrigeration device
frosting
The dirt deposited in the
container obstructs the
flow of refrigerant
Replace the container
4
The pressures of both the low-pressure end
and high-pressure end are over-high.
Refrigeration insufficient
Condenser refrigeration
insufficient
(1) Replace the condenser
(2) Check the operation of
fan motor
Chery B11 Service Manual
Air Conditioner-14
5
Excessive
refrigerant
charged
(1) Check the refrigerant
dosage,
such
as
excessive refrigerant
(2) Recycle the refrigerant
(3) Drain the air, and
charge appropriate
purified refrigerant
6
Refrigeration
device
with air
(1) Replace the container
(2) Check whether the
compressor oil is dirt
or not
(3) Repeatedly
conduct
the
air
drainage
operation to remove
the
air
from
the
refrigeration device
7
● Refrigeration insufficient
● In the low-pressure side
pipe, a large amount of
water beads appear or the
frosting
phenomenon
occurs
Expansion
valve
installation
incorrect,
and/or the heat sensing
tube
failure.
(The
opening is too wide)
(1) Check the installation
of heat sensing tube
If the result of (1) is
right,
(2) check the expansion
valve If the expansion
valve failure, replace
it
WARNING:
●
Take care to recycle the refrigerant before the components removal from the refrigerant pipe
and the air drainage .
●
The air must be drained after the components are installed on the refrigerant pipe, and the
appropriate purified refrigerant shall be charged.