Chery A15. Manual — part 143
When system pressure exceeds 220psi, high pressure switch closes and high-speed fan relay is
activated by earthing between pressure switch and air conditioner relay. Battery supplies
power to cooling fan motor through high-speed fan relay.
Section Four: Internal Circulation Electromagnetic Valve Circuit
I. Working Condition of Internal Circulation Electromagnetic Valve
Internal circulation switch is pressed down (please refer to circuit diagram in Section Five of
this Chapter).
II. Working Principles of Internal Circulation Electromagnetic Valve
When ignition switch is turned on, air conditioning blower relay coil is powered by wire X
and the contact of air conditioning blower fan is closed.
Press down internal circulation switch, battery supplies power to N63 internal circulation
electromagnetic valve through blower relay and internal circulation switch.
Section Five: Blower Circuit
I. Working Condition of Blower
Blower switch has four ranges, and blower speed has four levels accordingly.
棕/绿
1.0
绿/黄
1.0
棕
2.5
5
N23
1
2
E9
5
白/黑
1.0
兰
1.5
4
4
M
3
绿
2.5
1
黄/红
1.5
2
黑/红
2.5
白/黑
1.0
黑/红
2.5
绿/黄
0.5
棕
0.5
V2
N63
5
6
白/绿
1.0
1
白
0.5
2
黑/红
2.5
棕
0.5
3
4
2
1
黄/红
1.5
3
黑
2.5
8
2
1
白/绿
1.0
1
4
7
V
1.0
4
3
2
5
6
30
A
B4
R/
SC
K
FS
9
10
A
FS
12
IM
MO
E1
2
D1
3
D1
2
红
2.5
红/兰
2.5
棕
1.0
NR
0.5
85
12
V
86
鼓
风机继
电器
30
87
空调开关
空调继电器
温度
传感器
空调压力
高开压关
鼓风机开关
鼓风机
电阻
30
15
X
31
31
鼓风
机电
机
内外循
环电磁
阀
发动机电脑8#
发动机电脑67#
鼓风机继电器 Blower
relay
内外循环电磁阀
Internal/external circulation electromagnetic
valve
空调开关
Air conditioner switch
空调压力高压开关
Air conditioning high-pressure switch
空调继电器
Air conditioner relay
红 Red
鼓风机开关 Blower
switch
兰 Blue
温度传感器 Temperature
sensor
黑 Black
发动机电脑 67#
Engine computer 67#
白 White
发动机电脑 8#
Engine computer 8#
绿 Green
鼓风机电阻 Blower
resistor 黄 Yellow
鼓风机电机 Blower
motor
棕 Brown
II. Working Principle of Blower
When blower switch is placed to range 1, pin 2 and pin 5 of blower switch are connected.
Battery supplies power to blower through blower switch and all four dropping resistors of
serially connected blower speed-regulating resistors to start blower working at the lowest
speed.
When bower switch is placed to range 2, pin 2 and pin 4 of blower switch are connected.
Battery supplies power to blower through blower switch and three dropping resistors of
serially connected blower speed-regulating resistors to start blower working at speed level 2.
When bower switch is placed to range 3, pin 2 and pin 3 of blower switch are connected.
Battery supplies power to blower through blower switch and two dropping resistors of serially
connected blower speed-regulating resistors to start blower working at speed level 3.
When bower switch is placed to range 4, air conditioner relay is activated. Battery supplies
power directly to blower through blower switch without passing through any dropping resistor
to start blower working at the highest speed.
Section Six: Air Conditioner Control Panel
1. Blower switch
2. Temperature control switch
3. Airflow distribution switch
4. A/C switch
5. Internal circulation switch
Section Seven: Air Conditioning Compressor
1. Driving Belt Position
1-Engine
2-Water pump/Power steering pump
3-Compressor
4-Idler
5-Crank shaft
6-Tensioner
2. Coolant Pipeline Diagram
Compressor
Condenser
Evaporator
Fan
Drying bottle/collector
Expansion valve
Section Eight: Air Conditioning System Overview