Chery A11. Manual — part 181
Maintenance Manual for Chery · Windcloud
M7.9.7 EFI System
Failure code: P0507 higher idling speed than target value
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “OFF”.
Go to next step
Yes
Go to next step
2
Check throttle regulating screw, throttle cable and
working conditions of throttle to see if they are
normal.
No
Carry out
necessary
inspection,
repair and
maintenance
Yes
Go to next step
3
Check working conditions of idle speed regulator to
see if they are normal.
No
Carry out
necessary
inspection,
repair and
maintenance
Yes
Carry out
necessary
inspection and
repair
4
A. Check system for air leakage;
B. Check injectors for leakage;
C. Check fuel system pressure to see if it is too
high.
No
Diagnosis
Instruction
Failure code: P0508 too low control circuit voltage of idle speed regulator
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “ON”.
Go to next step
Yes
Go to next step
2
Unplug idle speed regulator connector, check
respectively the resistances between Pin A and Pin
D, Pin B and Pin C of the regulator with a
multimeter too see if they are around 53±5.3Ω at
20℃.
No
Replace
stepper motor
Yes
Repair or
replace wire
harness
3
Check respectively the connections between Pin A,
B, C, D of idle speed regulator connector and Pin
65, 66, 67, 64 of ECU to see if short circuit to
ground occurs.
No
Diagnosis
Instruction
Failure code: P0509 too high control circuit voltage of idle speed regulator
Step Operation
Result Solution
32
Maintenance Manual for Chery · Windcloud
M7.9.7 EFI System
1
Connect scanner and commutator, and then turn
ignition switch to “ON”.
Go to next step
Yes
Go to next step
2
Unplug idle speed regulator connector, check
respectively the resistances between Pin A and Pin
D, Pin B and Pin C of the regulator with a
multimeter too see if they are around 53±5.3Ω at
20℃.
No
Replace
stepper motor
Yes
Repair or
replace wire
harness
3
Check respectively the connections between Pin A,
B, C, D of idle speed regulator connector and Pin
65, 66, 67, 64 of ECU to see if short circuit occurs.
No
Diagnosis
Instruction
Failure code: P0511 control circuit error of idle speed regulator
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “ON”.
Go to next step
Yes
Go to next step
2
Unplug idle speed regulator connector, check
respectively the resistances between Pin A and Pin
D, Pin B and Pin C of the regulator with a
multimeter too see if they are around 53±5.3Ω at
20℃.
No
Replace
stepper motor
Yes
Repair or
replace wire
harness
3
Check respectively the connections between Pin A,
B, C, D of idle speed regulator connector and Pin
65, 66, 67, 64 of ECU to see if open circuit occurs.
No
Diagnosis
Instruction
Failure code: P0560 improper system voltage signal
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “OFF”.
Go to next step
Yes
Go to next step
2
Check battery voltage with a multimeter to see if it
is around 12V.
No
Replace
battery
Yes
Repair or
replace wire
harness
3
Check respectively the connections between Pin 44,
45, 63 of ECU and Pin 87 of main relay to see if
open circuit or short circuit to ground occurs.
No
Go to next step
Yes
Go to next step
4
Start engine, check charging voltage of generator at
different engine speeds to see if it maintains within
9-16V.
No
Replace
generator
33
Maintenance Manual for Chery · Windcloud
M7.9.7 EFI System
Yes
Diagnosis
Instruction
5
Check ground point of engine wire harness to see if
it is normal.
No
Repair or
replace wire
harness
Failure code: P0562 too low system voltage
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “OFF”.
Go to next step
Yes
Go to next step
2
Check battery voltage with a multimeter to see if it
is around 12V.
No
Replace
battery
Yes
Repair or
replace wire
harness
3
Check respectively the connections between Pin 44,
45, 63 of ECU and Pin 87 of main relay to see if the
resistances are too high.
No
Go to next step
Yes
Go to next step
4
Start engine, check charging voltage of generator at
different engine speeds to see if it maintains within
9-16V.
No
Replace
generator
Yes
Diagnosis
Instruction
5
Check ground point of engine wire harness to see if
it is in good condition.
No
Repair or
replace wire
harness
Failure code: P0563 too high system votage
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “OFF”.
Go to next step
Yes
Go to next step
2
Check battery voltage with a multimeter to see if it
is around 12V.
No
Replace
battery
Yes
Go to next step
3
Start engine, check charging voltage of generator at
different engine speeds to see if it maintains within
9-16V.
No
Replace
generator
Yes
Diagnosis
Instruction
4
Check ground point of engine wire harness to see if
it isin good condition.
No
Repair or
replace wire
harness
34
Maintenance Manual for Chery · Windcloud
M7.9.7 EFI System
Failure code: P0601 non-programmed check code error of ECU
Step Operation
Result Solution
Connect scanner and commutator, and then turn
ignition switch to “ON”.
1
Go to next step
Yes
Go to next step
2
Clear failure code, recheck the failure to see if it is a
constant failure.
No System
normal
3 Replace
ECU.
Finish
Failure code: P0602 non-programmed diagnostic data identification code
error of ECU
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “ON”.
Go to next step
Yes
Go to next step
2
Clear failure code, recheck the failure to see if it is a
constant failure.
No System
normal
3 Replace
ECU.
Finish
Failure code: P0645 control circuit error of air conditioner compressor
relay
Step Operation
Result Solution
1
Connect scanner and commutator, and then turn
ignition switch to “OFF”.
Go to next step
Yes
Go to Step 4
2
Unplug air conditioner compressor relay, turn
ignition switch to “ON”, check voltages between
Pin 30, 85 of relay and cathode of power supply to
see if they are around 12V.
No
Go to next step
Yes
Repair or
replace wire
harness
3
Check power supply terminal circuit of relay to see
if open circuit or short circuit to ground occurs.
No
Go to Step 2
Yes Replace
relay
4
Check the voltage between Pin 86 of relay (control
terminal of air conditioner compressor relay) and
cathode of power supply to see if it is around 3.7V.
No
Go to next step
Yes
Repair or
replace wire
harness
5
Check the connection between Pin 86 of relay
(control terminal of air conditioner compressor
relay) and Pin 70 of ECU to see if open circuit
occurs.
No
Diagnosis
Instruction
35