Jaguar XJ (X350). Manual — part 1259
Instrument Cluster (88.20.01)
Removal
1 . Lower and extend the steering column to its maximum rearward position.
2 . Disconnect the battery ground cable. <<414-01>>
3 . Remove the centre console. <<501-12>>
4 .
CAUTION: Make sure damage does not occur to the instrument panel finish panel.
Remove the instrument panel finish panel.
5 . Remove the instrument cluster finish panel.
6 . Detach the instrument cluster.
Remove the instrument cluster retaining nuts.
7 . Remove the instrument cluster.
Disconnect the electrical connectors.
Installation
1
.
NOTE:
A new instrument cluster must be configured using the Jaguar approved diagnostic
equipment.
To install, reverse the removal procedure.
www.
Instrument Cluster Lens (88.20.28)
Removal
1 . Remove the instrument cluster.
For additional information, refer to
2
.
CAUTION: Disassembly and assembly of the instrument cluster must only be carried
out in a dust free and electrostatically protected area.
CAUTION: Care must be taken when removing or installing the cluster lens not to
touch the dial faces or lens surface.
Remove the instrument cluster lens.
Installation
1
.
CAUTION: Care must be taken when installing the cluster lens to prevent damage to
the instrument cluster pointers.
To install, reverse the removal procedure.
413-06 : Horn
Specifications
Specifications
Torque Specifications
Description
Nm lb-ft lb-in
Horn Switch Retaining Screws 5
—
44
www.