Frelander 2. Manual — part 421
Climate Control - Thermostatic Expansion Valve
Removal and Installation
Removal
• NOTE: Removal steps in this procedure may contain installation details.
Disconnect the battery ground cable.
Refer to:
Specifications
(414-00 Battery and Charging System -
General Information, Specifications).
1.
Recover the A/C refrigerant.
Refer to:
Air Conditioning (A/C) System Recovery, Evacuation and
Charging
(412-00 Climate Control System - General Information,
General Procedures).
2.
Remove the plenum chamber panel.
Refer to:
Plenum Chamber
(412-01 Climate Control, Removal and
Installation).
3.
4. CAUTIONS:
Make sure that all openings are sealed. Use new
blanking caps.
Lubricate the new seals with clean refrigerant oil.
• NOTE: Install new O-ring seals.
Torque: 9 Nm
4.
Torque: 4 Nm
5.
Installation
To install, reverse the removal procedure.
1.
Climate Control - EvaporatorLHD AWD
Removal and Installation
Removal
• NOTE: The removal of this component involves cutting an aperture in the evaporator housing wall and cutting through
the high and low pressure A/C lines. A service repair kit is supplied to cover this procedure.
Disconnect the battery ground cable.
Refer to:
Specifications
(414-00 Battery and Charging System -
General Information, Specifications).
1.
Recover the A/C refrigerant.
Refer to:
Air Conditioning (A/C) System Recovery, Evacuation and
Charging
(412-00 Climate Control System - General Information,
General Procedures).
2.
Remove the plenum chamber panel.
Refer to:
Plenum Chamber
(412-01 Climate Control, Removal and
Installation).
3.
If installed, remove the anti-theft alarm horn with
integral battery.
4.
5.
CAUTION: Make sure that all openings are
sealed. Use new blanking caps.
Disconnect the A/C pipes from the TXV.
5.
6.
Remove the RH floor console extension.
7.
Remove the glove compartment.
Refer to:
Glove Compartment
(501-12 Instrument Panel and
Console, Removal and Installation).
8.
9.
10.
11.
12.
13.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.