Jeep Grand Cherokee WK. Manual — part 407
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS
DIAGNOSIS AND TESTING
8J - 2
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS
WK
B1200-AIRBAG WARNING INDICATOR CIRCUIT LOW
For a complete wiring diagram Refer to Section 8W.
•
When Monitored:
With the ignition on and when requested to turn on by the Occupant Restraint Controller (ORC).
•
Set Condition:
The Instrument Cluster software detects the voltage across the Airbag Lamp is below 0.5 volts when ON.
Possible Causes
INSTRUMENT CLUSTER
Diagnostic Test
1.
CHECK FOR ACTIVE DTC
NOTE: The Instrument Cluster performs internal tests on the Airbag Lamp during each ignition cycle.
With the scan tool, erase DTCs.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Wait for the Instrument Cluster to perform the bulb check.
With the scan tool, read DTCs.
Is the DTC active?
Yes
>> Replace and program the Instrument Cluster in accordance with the Service Information.
Perform BODY VERIFICATION TEST VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE)
No
>> Test complete.
WK
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS
8J - 3
B1201-AIRBAG WARNING INDICATOR CIRCUIT OPEN
For a complete wiring diagram Refer to Section 8W.
•
When Monitored:
With the ignition on and when requested to turn on by the Occupant Restraint Controller (ORC).
•
Set Condition:
The Instrument Cluster software detects the voltage across the Airbag Lamp is above 4.0 volts when ON.
Possible Causes
INSTRUMENT CLUSTER
Diagnostic Test
1.
CHECK FOR AN ACTIVE DTC
NOTE: The Instrument Cluster performs internal tests on the Airbag Lamp during each ignition cycle.
With the scan tool, erase DTCs.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Wait for the Instrument Cluster to perform the bulb check.
With the scan tool, read DTCs.
Is the DTC active?
Yes
>> Replace and program the Instrument Cluster in accordance with the Service Information.
Perform BODY VERIFICATION TEST VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE)
No
>> Test complete.
8J - 4
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS
WK
B123F-MENU SWITCH STUCK
WK
INSTRUMENT CLUSTER - ELECTRICAL DIAGNOSTICS
8J - 5