Iveco Daily. Manual — part 344
FILLER CYLINDER
OIL TANK
50634
50632
Figure 19
Figure 20
18
CAB AIR-CONDITIONING
D
AILY
CONTROL FASCIA
M1
Low pressure gauge
M2
High pressure gauge
M3
Filler cylinder pressure gauge
LOW Low-pressure valve
HIGH High-pressure valve
REF
Refrigerant filler and drain valve
V1
Valve on low-pressure pipe
V2
Valve on high-pressure pipe
V3
Oil injection valve for A/C system
V5
Oil drainage valve
V9
A/C system washing refrigerant service valve
10
Moisture indicator
VS
Safety and drainage valve
L3
Alarm warning light
L4
Maximum level warning light
L5
Minimum level warning light
A
Unit process / bottle heater switch
LA1
Unit process indicator light
LA2
Bottle heater indicator light
B
Refrigerant process / vacuum process switch
LB1
Refrigerant process indicator light
LB2
Vacuum process indicator light
C
Recovery recycle cycle / Filling switch
LC1
Recovery recycle cycle indicator light
LC2
Filling indicator light
D
Vacuum / vacuum test switch
LD1
Vacuum indicator light
LD2
Vacuum test indicator light
Control fascia diagram legend
Filler cylinder legend
1
Pressure values in bar (vertical lines, revolving top
cylinder).
2
Weight of load in grams (oblique lines, revolving top
cylinder) 50 g division between lines.
3
Tank level viewer (internal cylinder).
CAB AIR-CONDITIONING
19
D
AILY
- never expose the unit or operate it in acidic or wet
environments or close to open containers of inflammable
substances;
- the unit must operate in places with good ventilation;
- never alter the settings of the safety valves and control
systems;
- never use bottles or other storage containers that are not
approved and are not fitted with safety valves;
- never load any container over 80% of its maximum
capacity;
- never leave the unit powered if it is not to be used
immediately. Cut off the mains power supply when it is
not planned to use the equipment.
SAFETY STANDARDS
- always wear gloves and goggles when working with
refrigerant gases. Contact of refrigerant liquid with the
eyes can cause blindness;
- avoid all contact with skin (low boiling point -30
°C can
cause frostbite);
- never inhale the vapours of refrigerant gases;
- before connecting the station with a system or external
container, check that all the valves are closed;
- before disconnecting the station, check that the cycle is
over and all the valves are closed. This will prevent
dispersing refrigerant gas into the atmosphere;
The station is equipped with special fittings to avoid
contamination with systems using R12. Do not attempt to
adapt this unit for use with R12.
This station is exclusively for professionally trained
operators who must be familiar with refrigerating
systems,
refrigerant
gases
and
the
damage
pressurized equipment can cause, therefore:
20
CAB AIR-CONDITIONING
D
AILY
Fully load
the system
Drain off oil
from the system
Is there any
leakage?
Preparing the station
First recovery
Wait 3-5 minutes
Second recovery
Operate on the system
Vacuum for 5-10 minutes
with first vacuum test
Vacuum for 30 minutes
with second vacuum test
Load oil
into the system
Load up to 200 g
refrigerant
Search for leakage with
electronic leak finder
Search system for leakage
with electronic leak finder
Pressure check
Are the values
acceptable?
Disconnect the station
from the system
NO
NO
YES
YES
NO
NO
YES
YES
YES
NO
Is there any
leakage?
Is there any
leakage?
Is there any
leakage?
CAB AIR-CONDITIONING
21
D
AILY
OPERATION FLOW CHART