Iveco Daily. Manual — part 52
ENGINES
8140.43R/B/S/N
190
D
AILY
B
as
e
-
M
ay
2004
Prin
t
603.93.281
DTC
FMI
Failing
component
Type of
Failure
Visible failure
Possible Cause
Repair action
Checks to be
performed
Measuring
conditions
Values to be
detected
Remarks
68
08
ELECTRONIC
CONTROL
UNIT
-
INTERNAL ECU
FAULT
SIGNAL
NOT
PLAUSIBLE
Wrong
ECU
programming.
Probable
electromagnetic
interference.
Faulty ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
69
01
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
EXCEEDED
UPPER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
69
02
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
BELOW
LOWER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
ENGINES
8140.43R/B/S/N
191
D
AILY
B
as
e
-
M
ay
2004
Prin
t
603.93.281
DTC
FMI
Failing
component
Type of
Failure
Visible failure
Possible Cause
Repair action
Checks to be
performed
Measuring
conditions
Values to be
detected
Remarks
6A
01
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
EXCEEDED
UPPER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
6A
02
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
BELOW
LOWER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
6B
01
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
EXCEEDED
UPPER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
ENGINES
8140.43R/B/S/N
192
D
AILY
B
as
e
-
M
ay
2004
Prin
t
603.93.281
DTC
FMI
Failing
component
Type of
Failure
Visible failure
Possible Cause
Repair action
Checks to be
performed
Measuring
conditions
Values to be
detected
Remarks
6B
02
ELECTRONIC
CONTROL
UNIT - SENSOR
POWER SUPPLY
BELOW
LOWER
LIMIT
Anomalous
engine
operation
due
to
incorrectly
powered
sensors.
Reduced
power.
Sensor
power
circuit fault in
ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
Possible
fault
indications
of
various sensors
powered
by
ECU.
6C
01
VEHICLE - EDC
LAMP
EXCEEDED
UPPER
LIMIT
Warning
light
not working.
Short-circuit to
positive.
Check
correct
operation
of
warning light using
”Active diagnostic”
procedure.
Warning
light
should come on
for
approximately 5
seconds
at
key-on.
Check
wiring
and
connections
if
this does not
occur.
6C
02
VEHICLE - EDC
LAMP
BELOW
LOWER
LIMIT
Warning
light
not working.
Short-circuit to
ground.
Check
correct
operation
of
warning light using
”Active diagnostic”
procedure.
Warning
light
should come on
for
approximately 5
seconds
at
key-on.
Check
wiring
and
connections
if
this does not
occur.
6C
04
VEHICLE - EDC
LAMP
NO
SIGNAL
Warning
light
not working.
Open
circuit,
bulb
disconnected.
Check
correct
operation
of
warning light using
”Active diagnostic”
procedure.
Warning
light
should come on
for
approximately 5
seconds
at
key-on.
Check
wiring
and
connections
if
this does not
occur.
ENGINES
8140.43R/B/S/N
193
D
AILY
B
as
e
-
M
ay
2004
Prin
t
603.93.281
DTC
FMI
Failing
component
Type of
Failure
Visible failure
Possible Cause
Repair action
Checks to be
performed
Measuring
conditions
Values to be
detected
Remarks
6C
08
VEHICLE - EDC
LAMP
SIGNAL
NOT
PLAUSIBLE
Warning
light
not working.
Wiring
problems.
Check wiring and
connections.
Replace sensor if
required.
Warning
light
should come on
for
approximately 5
seconds
at
key-on.
Check
wiring
and
connections
if
this does not
occur.
6D
08
ENGINE
2
-
INTERNAL ECU
FAULT
(PLAUSIBILTY
ERROR +15)
SIGNAL
NOT
PLAUSIBLE
Check wiring and
connections.
Key 15 off during
initialisation.
6E
08
ELECTRONIC
CONTROL
UNIT
-
INTERNAL ECU
FAULT
SIGNAL
NOT
PLAUSIBLE
Wrong
ECU
programming.
Probable
electromagnetic
interference.
Faulty ECU.
Switch key on/off
and wait for a few
seconds,
clear
failure memory. If
the error persists,
call the Help Desk
for instructions on
how to replace the
ECU.
75
01
VEHICLE
-
VEHICLE SPEED
SENSOR
/
SIGNAL
EXCEEDED
UPPER
LIMIT
Speed of 170
km/h exceeded.
Check
correct
calibration
of
speedometer.
Encourage
driver to use the
vehicle
correctly.
75
04
VEHICLE
-
VEHICLE SPEED
SENSOR
/
SIGNAL
NO
SIGNAL
Interrupted
wiring between
vehicle
speed
sensor
and
instrument
panel.
Check wiring and
connections
between
vehicle
speed sensor and
instrument panel.
75
04
VEHICLE
-
VEHICLE SPEED
SENSOR
/
SIGNAL
NO
SIGNAL
Wiring
interrupted
between
instrument
panel and EDC
ECU.
Check wiring and
connections
between instrument
panel
and
EDC
ECU.
Intervention
required
if
instrument
panel indicates
vehicle speed.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.