Geely Emgrand X7. Manual part — 440
Geely Emgrand X7. Manual part - 440
7
Repair the blower.
A. Repair according to the following list of symptoms
Symptoms Suspected
fault
part
Maintenance
scheme
Blower jamming
The blower wheel has foreign
matter.
The blower wheel is damaged.
The blower motor has foreign
matter and is blocked.
Clean up the blower wheel foreign body.
Clean up the blower motor foreign body.
Replace blower motor assembly, included
fan impeller
The blower motor does not
work.
The blower motor is damaged.
Replace blower motor assembly, included
fan impeller
B. Confirm that the blower works normally.
Confirm the completion of repair.
8
The system is normal.
Next
1759
8.3.7.6 A/C system cooling capacity is lack
Fault symptom table
Symptoms
Suspected fault part
Maintenance scheme
The engine
coolant
temperature is
too high.
1. Engine idle running time is
too long.
2. Engine is running with
overload for long time
3. Coolant
is
lock
4. Coolant performance can’t
meet requirement.
5. Thermostat
Malfunctions
6. The engine is in poor
operation.
7. The cooling fan is in
abnormal operation.
8. The cooling fan does not
work.
9. The water tank is in poor
heat dissipation.
10. Cooling fan air connection
cover.
1.Reduce engine idling running time
2. Reduced engine running time with big load.
3. Overhaul leakage condition of coolant , added coolant
to the standard value
4. Replace coolant which meets requirements of Geely.
5. Replace
the
thermostat
6. Check the cooling system of the engine
7. Service the engine to check its working condition.
8. Service the cooling fan motor and its circuits and
replace if necessary.
9. Clean the cooling water tank.
10. Overhaul cooling water tank, if necessary, replace it.
11. Overhaul cooling fan wind concentrator cowl. if
necessary,replace it
Condenser
temperature is
too high
1. Condenser
radiation
is
bad.
2. Water temperature of engine
is too high
1
Clean the condenser
2. Overhaul condenser. If necessary, replace it
3. Conduct repair according to symptom specified in this
table "engine coolant temperature is too high".
The
compressor
runs
abnormally.
1. Compresor belt is skidding.
2. Compressor clutch is
skidding.
3. Compressor has abnormal
sound
4. Frequent start of compressor
5.
Operation Failure of
Compressor
1. Adjust compressor belt, and replace when necessary
2. Repair the compressor clutch and replace if necessary.
3. Inspect the amount of the refrigerant and the
lubrication oil. Refer to the symptom of "abnormal
A/C system pressure" in the table.
4. Repair the compressor clutch circuit.
5. Repair the compressor and replace if necessary.
6. Repair the A/C pressure switch, and replace if
necessary.
7. Repair the A/C control module, and replace if
necessary.
8. Overhaul engine control module.if necessary.replace it
Air volume of
the instrument
panel air outlet
is too small.
1. Instrument air duct blocked
2. Instrument air duct leakage
3. Air direction control
mechanism abnormal
4. Air direction control motor
abnormal
5. Blower speed is too low.
6. Blower Speed Control
Module abnormal
7. A/C pipe frozen
8. A/C control module
abnormal
1. Clean up the air outlet of the instrument panel and
replace if necessary.
2. Repair the air outlet passage of the instrument panel
and replace if necessary.
3. Overhaul wind control mechanism
4. Overhaul wind control motor
5. Repair circuit.
6. Repair the blower motor and replace if necessary.
7. Replace blower speed regulation module
8. Replace the refrigerant according with the standard of
Geely manufacturer.
9. Replace expansion valve
1760
10. Repair the A/C control module circuit, and replace
module if necessary.
Air-out
temperature of
the instrument
panel air outlet
is too high.
1. Switched to outside
circulation
2. Ambient temperature is too
high
3. The outside circulation
throttle is blocked and not
closed tightly.
4. Inside and outside
circulation motors fault
5. Temperature control
mechanical is abnormal.
6. Temperature control motor
is abnormal.
7. Abnormal illumination
sensor
8. A/C control module
abnormal
1. Switch to inside circulation.
2. Move the vehicle to a cool and shaded place.
3. Adjust outside circulation throttle mechanism, and
replace the internal and outside circulation throttle
mechanism when necessary.
4. Replace Inside and outside circulation adjustment
motor
5. Repair the temperature control motor, and replace if
necessary.
6. Repair the light sensor and replace if necessary.
7. Repair the A/C control module circuit, and replace
module if necessary.
A/C high
pressure is too
high and low
pressure is too
high.
1. Refrigeration System has air
2. Refrigerant charging is too
much
3. Refrigerant lubricating oil
charging is too much
4. The expansion valve
opening is too large.
1. Repair the leakproofness of the pipeline of the
refrigerating system and refill the refrigerant.
2. Discharge excessive refrigerant.
3. Discharge excessive refrigerant lubricating oil.
4. Replace expansion valve
A/C high
pressure is too
high and low
pressure is too
low.
1. High-pressure pipe prior to
the expansion valve is
blocked.
2. Expansion valve blockage
3. The expansion valve
opening is too small.
1. Wash or replace blocked high-pressure pipe.
2. Replace expansion valve
A/C high
pressure is too
low and low
pressure is too
high.
1. The compressor lacks of oil.
1. The compressor is damaged.
1. Supplement with the compressor refrigerant
lubricating oil.
1. Replace compressor
A/C high
pressure and
low pressure
are too low.
1. Refrigerant charging
capacity is not enough
2. Refrigerant is leakage
1. Fill with the A/C refrigerant according to the standard
as specified by Geely.
2. Repair the leakage condition of the A/C system; and
replace the A/C system element leaked.
A/C high
pressure is too
low and low
pressure in
vacuum.
1. The expansion valve is in
serious filth blockage.
2. Expansion valve ice block
3. Evaporator temperature
sensor faults.
4. Low-pressure pipeline
leakage
1. Replace expansion valve
2. Prolong the pumpdown time of the system and fill the
A/C refrigerant which is accorded with the standard
specified by Geely manufacturer.
3. Replace stock solution dryer.
4. Replace evaporator temperature sensor
5. Wash or replace blocked low-pressure pipe.
1761
8.3.7.7 A/C system air warming is lack
Fault symptom table
Symptoms
Suspected fault part
Maintenance scheme
The engine coolant temperature
does not reach 82℃ (180℉).
1. Thermostat Malfunction
2. Insufficient running time of engine
3. Air entering the cooling system
4. Poor engine working conditions.
1. Prolong the running time of the
engine.
2. Empty the air in the cooling
system
3. Replace the thermostat.
4. Overhaul engine work
condition
Air leakage of cold-warm valve
1. Mechanical fault of cold-warm
valve mechanism
2. Cold-warm valve motor fault
3. The air outlet way leaks air.
4. A/C control module faults.
1. Adjust throttle mechanism
2. Replace cool-warn adjusting
motor
3. Replace Coo-warm valve
mechanism
4. Repair the air leakage passage.
5. Replace air leakage passage.
6. Replace A/C control module
Inside and outside circulation
throttle leaks air.
1. Switched to outside circulation
2. The outside circulation throttle is
blocked and not closed tightly.
3. Inside and outside circulation
motors fault
4. A/C control module faults.
1. Switch to inside circulation.
2. Adjust outside circulation
throttle mechanism
3. Replace inside and outside
circulation adjustment motor
4. Replace inside and outside
circulation valve mechanism
5. Replace A/C control module
1762