Geely Emgrand X7. Manual part — 483
Geely Emgrand X7. Manual part - 483
3
Replace the BCM
(a) Replace BCM and refer to
Replacement of BCM in 11.8.8.1
.
Confirm the completion of repair.
4
The system is normal.
Next
1931
10.2.4.15 DTC B1217
Fault diagnosis code Descriptions
B1217
Open circuit incurs on driver-side electric window driving.
Circuit diagram:
B
8
7 IP47
M
DR02
A DR02
B
15
14 IP47
M
DR11
A DR11
IP47
IP47
LF-WINDOW
DOWN
RF-WINDOW
DOWN
RF-WINDOW UP
LF-WINDOW UP
BCM
左前玻璃升降电机
右前门窗升降电机
NL11-3222b
Diagnostic Steps:
1
Inspect whether there is any DTC Code other than B1214.
(a) Inspect whether there is any DTC Code other than B1217.
2
Inspect the upshift voltage of the left front glass lifting
motor.
Yes
Go to
DTC list in 10.2.4.2
and repair according to
trouble codes.
No
Left frontglass
lifting motor
Right front door
and window lifting
motor
1932
(a) Turn on left front glass lifter switch to lift left
front glass.
(b) Measure voltage of Left front glass lift motor
harness connector DR02 terminal
Standard Voltage: 11-14 V
Is voltage the Standard Value?
NL11-3223b
A
B
DR02左前玻璃升降电机线束连接器
3
Inspect the downshift voltage of the left front glass lifting
motor.
(a) Turn on left front glass lifter switch to lower
left front glass.
(b) Measure voltage of Left front glass lift motor
harness connector DR02 terminal
Standard Voltage: 11-14 V
Is voltage the Standard Value?
NL11-3224b
A
B
DR02左前玻璃升降电机线束连接器
4
Inspect the communication of the left front glass lifting motor
and the BCM.
No
Go to step 4
Yes
No
Go to step 5
Yes
DR02Left frontglass lifting motor harness
connector
DR02Left frontglass lifting motor harness
connector
1933
(a) Turn the ignition switch to OFF position.
(b) Disconnect Left front glass lift motor
harness connector DR02.
(c) Disconnect BCM harness connector IP47.
(d) Measure left front glass lifter motor wire
harness connector DR02 terminal A and BCM
wire harness connector IP47 terminal 7.
(e) Measure left front glass lifter motor wire
harness connector DR02 terminal B and BCM
wire harness connector IP47 terminal 8.
Standard Resistance: Less than 1 Ω
Is the resistance at a specified value?
NL11-3225b
A
B
DR02左前玻璃升降电机线束连接器
IP47BCM线束连接器
5 6 7 8
9 10 11 12
13
14 15 16 17
1
2 3 4
5
Replace left front glass lift motor,
(a) Replace left front glass lift motor; refer to
11.4.8.5 Replacement of left front glass lifter motor
.
(b)
Clear DTC, and read DTC again
Whether fault code exists or not.
6
Replace the BCM
(a) Replace BCM and refer to
Replacement of BCM in 11.8.8.1
.
Confirm the completion of repair.
7
The system is normal.
Next
No
The system is normal.
Yes
Yes
Go to step 6
No
IP47BCMharness connector
DR02Left frontglass lifting motor harness
connector
1934
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст