Geely Emgrand X7. Manual part — 342
Geely Emgrand X7. Manual part - 342
3.5.7.25 P0976 P0977
1. DTC
description:
DTC P0976 On/off electromagnetic valve S2 high current (short circuit)
DTC P0977 On/off electromagnetic valve S2 low current (open circuit)
The transmission control unit (TCU) uses a switching electromagnetic valve to select among different clutch
elements within the transmission. During operation, the transmission control unit evaluates the current
actually-delivered current to open/close the electromagnetic valve and compares with the expected. If the current
is not in the pre-defined parameter currently, the DTC is set to display abnormal load of the transmission control
unit.
2. Conditions For Setting DTC and The Fault Position :
DTC Code
DTC Detection Strategy
Conditions For Setting The DTC
(Control Strategy)
Fault Position s
P0976
Feedback information of
on/off electromagnetic valve
S2 is that existence of short
circuit.
P0977
Feedback information of
on/off electromagnetic valve
S2 is that existence of open
circuit.
1. Ignition switch is in the “ON”
position.
2. Electromagnetic valve power on
3. TCU power supply voltage is
normal
1. Electromagnetic
valve
2. Electromagnetic
valve circuit
3. TCU
3. Circuit
sketch
1367
T
C
U
电磁阀
换挡器
档位开关
LEVER
REVERSE
START
VBS5
VBS6
VBS7
V
BS8
VBS9
VBS1
0
O
n
O
ff
1
O
n
O
ff
2
O
n
O
ff
3
O
n
O
ff
4
EMM
INPUT
SHAFT
SPEE
D
SENSOR
OU
TPUT
SHAFT
t
SPE
ED
SENSOR
25
26
10
11
9
8
13
12
24
23
22
21
20
7
6
5
4
3
2
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
J-4
1
18
8
1
3
2
12
14
4
11
12
9
10
15
2
1
4
3
6
5
7
7
J-5
5
16
17
J-5
4
J-5
1
J-5
6
J-5
2
J-5
3
4
11
10
10
15
3
CAN H
启动继电器
倒车信号
输出
主继电器
JF-1
IG2
JB-2
CAN L
10
20
J-3
J-1
J-3
J-2
J-2
J-3
J-3
J-3
J-1
8
J-3
J-3
J-3
J-3
J-3
J-3
J-3
J-3
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
J-1
IF36
NL03-2005c
4. Diagnostic
procedures:
Note: Before carrying out this diagnosis step, observe the data list on fault diagnosis tester and analyze the
accuracy of the data, as these will help with quick diagnosis.
1
Read the fault code again after clearing away the fault code to Check if fault codes, except DTC
P0976 and P0977 exist in the control system.
A. Connect fault diagnosis tester to the datalink connector.
B. Rotated ignition switch to ON position
C. Switch on fault diagnostic device power supply
D. Clear DTC code.
E. Reset reading fault code, and check if DTCs meet setting condition of fault code in current
DTC Codes Shown
To Step
DTC P0976 P0977
Yes
DTCs other than DTCs P0976 and P0977
No
Gears switch
Main relay
JF-1
Reverse output
signal
Start relay JB-2
Shifter
Electromagnetic
valve
1368
2
Detect TCUpower supply circuit
See 3.5.7.8 P0603 P0604 P1604 P1701 P1703
3
Detect ON/OFF electromagnetic valveS2resistance
A. Turn the ignition switch to the OFF position.
B. Disconnect the harness connector J-4 of the
electromagnetic valve.
C. Measure the resistance between Terminals 22 and
20 of the electromagnetic valve harness
connector J-4.
Standard resistant value :20.8Ω-23.2Ω
电磁阀线束连接器
J-4
1
8
20
14
9
15
10
16
11
17
12
18
13
19
2
21
3
22
4
23
5
24
6
25
7
26
SL03-0036c
Does it conform to the standard value?
3
Detect ON/OFF electromagnetic valve S2 circuit
No
Yes
Refer to3.4.7.6 fault diagnosis code (DTC) chapter
index
Next
No
Yes
Replace auto-transmission assembly, refer
to3.4.7.6 auto-transmission assembly replacement
Electromagnetic valveharness connectorJ-4
1369
A. rotated ignition switch to OFF position.
B. Disconnect the harness connector J-4 of the
electromagnetic valve.
C. Measure the resistance between Terminal No.22
of the electromagnetic valve harness connector
J-4 and Terminal 9 of the automatic control
module J-1.
D. Measure the resistance between Terminal No.20
of the electromagnetic valve harness connector
J-4 and Terminal No.15 of the automatic control
module J-1.
E. Turn the ignition switch to the ON position.
F. Measure voltage of electromagnetic valve
harness connector J-4No.22 terminal and reliable
grounding
自动变速器控制模块线束连接器
J-1
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
SL03-0034c
G. Measure the resistance between Terminal No.20 of the electromagnetic valve harness connector J-4 and
secure ground wire.
Results
Test Items
Standard Value
J-4 (22) — J-1(9)
Less than 3 Ω
J-4 (20) — J-1(15)
Less than 3 Ω
J-4 (22) — Reliable grounding voltage value
0 V
J-4 (20) — Reliable grounding resistance value
Less than 3 Ω
Does it conform to the standard value?
4 ReplaceTCU
Refer to3.5.7.8 replace automatic transmission control module
5
Go to automatic transmission fresh process.
Refer to3.5.7.4 Automatic transmission refresh process
No
Yes
Circuit malfunction, repair circuit.
Next
Auto-transmissioncontrol module harness connectorJ-1
1370
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст