Geely Emgrand X7. Manual part — 426
Geely Emgrand X7. Manual part - 426
12
Lamplet (+)
0.3L
Input
+12v DC signal
13 Ground
0.3B
Output GND
DC
signal
14 Ground
0.3B
Output GND
DC
signal
15 -
-
-
-
16 -
-
-
-
17 -
-
-
-
18 -
-
-
-
19 -
-
-
-
20 -
-
-
-
21
Speed signal
0.3Y/G
Input
Pulse signal
22
Rear defrost signal
0.3O
Input
A627 A628 DC signal
23
Ignition switch 2
0.3R/G
Input
A627 A628 DC signal
8.2.7.4 Data flow table
Serial
Number
Description
Range of data
1 Inside
Temperature
Sensor
-40℃- 80℃
2
Outside Temperature Sensor
-40℃- 80℃
3 Evaporator
temperature
sensor
-40℃- 80℃
4
Heater temperature sensor
-40℃- 80℃
5 Sunlight
sensor
0W-W
6
Temperature regulating motor
0%-100%
7
Air Direction Adjusting Motor
0%-100%
8
Inside and outside circulation motors
Inside/outside
9
Backlight adjustment
PWM signal.0%-100%
10 Compressor
control
On/Off
11 Rear
defrost
control
On/Off
12 Vehicle
speed
signal
0-255Km/h
13 Blower
voltage
0-16.5V
14 Battery
voltage
0-18.5V
1703
8.2.7.5 Controller self-inspection testing
1
The ignition switch is turned from the gear OFF to the gear ON.
2
Continuously press the "Circulated Air" switch 4 times within 2 seconds when the "OFF" switch is
pressed.
3
Start self-inspection testing after the LCD backlight flickers 3 times.
4
Self-inspection item,
5
Self-inspection item,
A. For replacement of the A/C control module, see "8.2.8.1 replacement of A/C control module".
Does the blower operate normally?
6
Control A/C ,
1. During self-inspection function running, data display area is the position to set teperature displaying, while
other positions are "OFF" status.
2. During running of self-inspection function, A/C is controlled to be "OFF" status.
3. During self-inspection function running, the set temperature display position will be shown at every 0.5s and
then fault code will be shown.
4. In the self-inspection test, keep the MODE characters in the previous state but do not run them.
5. When the vehicle is in the IGN2 OFF ON mode during the self-inspection testing, the vehicle will return to
the OFF mode.
6. The display in the continuous operation mode is as follows:
–
Normal condition or fault condition last for 1h:
Next
Next
Press the A/C
switch.
Press the "OFF"
switch.
Go to step 6
Press the "OFF"
switch.
Next
1704
NL08-2034b
显示
灯亮
0.5s
灯亮
熄灯
0.5s
–
When it have many faults
NL08-2035b
显示
故障1
故障2
故障N
故障1
. ..
8.2.7.6 DTC List
Serial Number Fault content
Remarks:
00 Normal
11
Open circuit of indoor temperature sensor
12
Short circuit of indoor temperature sensor
13
Ambient air temperature is short circuit
14
Ambient air temperature short circuit
17 Evaporator
sensor
open
18
Evaporator sensor shorted
19
Short circuit or open circuit of driver-side temperature
throttle motor
20
Driver-side temperature throttle motor is blocked.
21
Model air motor shorted or open
In case the motor is unable to reach
the specific location within 40s, it is
judged as blocked.
Display
Light is
“on”
Light is
“on”
Lights out
Display
Fault 1
Fault 2
Fault N
Fault 1
1705
22
Model air motor locked
25
In case the motor is unable to reach the specific
location within 40s, it is judged as blocked.
26
Air inlet motor locked
32
Passenger side temperature motor shorted or open
33
Passenger side temperature motor locked
8.2.7.7 Electrical Device Failure Relevance
Serial
Number
Items Status
Fault
protection
1
Inside Temperature
Sensor
Short circuit or open
circuit
Default temperature 25℃
2 Ambient
air
temperature
Short circuit or open
circuit
Default temperature 20℃
3
Evaporator temperature
sensor
Short circuit or open
circuit
Default temperature -2℃
When the set temperature is 17℃-24.5℃,
fix in the MAX COOL position.
4
Temperature throttle
motor
Short circuit or open
circuit
When the set temperature is 25℃-32℃, fix
in the MAX HOT position.
Position surface-blowing mode: fixing in the
surface-blowing mode
5
Mode throttle motor
Short circuit or open
circuit
Kept in the defrosting mode.
Fresh air mode: fixed in the fresh air mode.
6
Air intake valve motor
Short circuit or open
circuit
Air returning mode: fixed in the air
returning mode
7 Sunlight
sensor
Short circuit or open
circuit
Default illumination 0 W/m2
1706