Geely Emgrand X7. Manual part — 340

Geely Emgrand X7. Manual part - 340


2

Detect TCUpower supply circuit

See 3.5.7.8 P0603 P0604 P1604 P1701 P1703

3

Detect S8electromagnetic valve resistance

A. Turn the ignition switch to the OFF position.

B. Disconnect the harness connector J-4 of the

electromagnetic valve.

C. Measure the resistance between Terminals 5 and

1 of the electromagnetic valve harness connector
J-4.

Standard resistant value :4.11Ω-4.17Ω

电磁阀线束连接器

J-4

1

8

20

14

9

15

10

16

11

17

12

18

13

19

2

21

3

22

4

23

5

24

6

25

7

26

SL03-0036c

Does it conform to the standard value?

3

Detect S8electromagnetic valve circuit

No

Yes

Refer to3.4.7.6 fault diagnosis code (DTC)
chapter index

Next

No

Yes

Replace auto-transmission assembly, refer
to3.4.7.6 auto-transmission assembly replacement

Electromagnetic valve harness connectorJ-4

1359


A. rotated ignition switch to OFF position.

B. Disconnect the harness connector J-4 of the

electromagnetic valve.

C. Measure the resistance between Terminal 5 of the

electromagnetic valve harness connector J-4 and
Terminal 4 of the automatic control module J-1.

D. Measure the resistance between Terminal No.1 of

the electromagnetic valve harness connector J-4
and Terminal 7 of the automatic control module
J-1.

E. Turn the ignition switch to the ON position.

F. Measure voltage of electromagnetic valve

harness connector J-4No.5 terminal and reliable
grounding

自动变速器控制模块线束连接器

J-1

1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

SL03-0034c

G. Measure the resistance between Terminal No.1 of the electromagnetic valve harness connector J-4 and secure

ground wire.

Results

Test items

Standard value

J-4 (5) — J-1(4)

Less than 3 Ω

J-4 (1) — J-1(7)

Less than 3 Ω

J-4 (5) — Reliable grounding voltage value

0 V

J-4 (1) — Reliable grounding resistance value

Less than 3 Ω

Does it conform to the standard value?

4 ReplaceTCU

Refer to3.5.7.8 replace automatic transmission control module

5

Go to automatic transmission fresh process.

Refer to3.5.7.4 Automatic transmission refresh process

No

Yes

Circuit malfunction,repair circuit.

Next

Auto-transmissioncontrol module harness connectorJ-1

1360


6

Use fault diagnosis tester to confirm if DTC is stored again.

A. Connect fault diagnosis tester to the data link connector.

B. Rotated ignition switches to ON position.

C. Clear DTC code.

D. Start and run the engine at idle speed to warm up the engine for at least 5min.

E Read control system DTC code again to confirm that the system has no DTC code exported.

7 Troubleshooting

5. Maintenance

guide:

Replace Automatic transmission control module, refer to3.5.7.8 replace automatic transmission control module

Replace AutomaticTransmission assembly , refer to3.5.7.6 AutomaticTransmission assembly replacement

Yes

No

Next

Refer to 2.2.7.3 Intermittent Fault Inspection for
intermittent fault.

1361


3.5.7.24 P0973 P0974

1. DTC

description:

DTC P0973

On/off electromagnetic valve S1 high current (short circuit)

DTC P0974

On/off electromagnetic valve S1 low current (open circuit)

The transmission control unit (TCU) uses a switching electromagnetic valve to select among different clutch
elements within the transmission. During operation, the transmission control unit evaluates the current
actually-delivered current to open/close the electromagnetic valve and compares with the expected. If the current
is not in the pre-defined parameter currently, the DTC is set to display abnormal load of the transmission control
unit.

2. Conditions For Setting DTC and The Fault Position :

DTC Code DTC Detection Strategy

Conditions For Setting The DTC
(Control Strategy)

Fault Position s

P0973

Feedback information of
on/off electromagnetic valve
S1 is that existence of short
circuit.

P0974

Feedback information of
on/off electromagnetic valve
S1 is that existence of open
circuit.

1. Ignition switch is in the “ON”

position.

2. Electromagnetic valve power on

3. TCU power supply voltage is
normal

1. Electromagnetic

valve

2. Electromagnetic

valve circuit

3. TCU

3. Circuit

sketch

1362

Была ли эта страница вам полезна?
Да!Нет
5 посетителей считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности