Geely Emgrand X7. Manual part — 457
Geely Emgrand X7. Manual part - 457
Is the system working normally?
1827
8
Replace the airbag control module.
A. Replace the airbag control module. Refer to 9.2.7.1 Replacement of Airbag Control Module.
B. Confirm that the repair is completed.
9
The system is normal.
No
Yes
The system is normal.
Next
1828
Actuator Malfunction
Note: The workshop manual only diagnoses the driver airbag and driver seatbelt preloader, the rest actuators
diagnostics are similar. Please refer to Driver Airbag and Driver Seatbelt Preloader Diagnostic.
Driver Airbag Malfunction
Diagnostic Trouble Code (DTC)
Descriptions
B102100
High Resistance of Driver Airbag Module
B102200
Low Resistance of Driver Airbag Module
B102300
High Resistance of Driver Airbag Module
B102400 Driver
Airbag
Module
Short Circuit over the Voltage
Circuit diagram:
Refer to 9.2.6.4 Circuit Diagram in Warning Lamp Always On.
Diagnostic Steps:
1
Check the harness (Airbag Electronic Control Unit - power supply, Ground).
A. Disconnect the battery negative cable, turn the
ignition switch to OFF position and wait for 90
seconds. Pull down the connector from the airbag
control module.
B. Connect the battery negative cable and wait for at
least 2s .
C. Turn the ignition switch to ON (IG).
D. Measure the voltage between terminal No.30 of
harness connector IP15 and vehicle body ground
with a multimeter.
Standard Voltage: 11-14 V
E. Turn the ignition switch to OFF position .
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
IP15安全气囊控制模块线束连接器
NL09-2102b
F. Measure the resistance between terminal No.5 of harness connector IP15 and vehicle body ground with a
multimeter.
Standard Resistance: Less than 1 Ω
2
Check the harness connector.
A. Disconnect the battery negative cable and wait for at least 90s. Refer to 2.12.6.1 Battery Cable Disconnection
and Connection Procedures.
B. Check whether the clock spring connector is damaged, whether the retaining buckle is damaged.
Yes
No
Inspect the fuses, repair or replace the harness.
No
Yes
Replace the clock spring.
IP15airbag control module harness
connector
1829
3
Inspect the circuit between the airbag control module and driver airbag.
A. Disconnect the battery negative cable and wait for at least 90s. Refer to 2.12.6.1 Battery Cable Disconnection
and Connection Procedures.
B. Disconnect the clock spring harness connector form the driver airbag.
C. Disconnect harness connector from the airbag control module.
Note: Before measuring, please dismantle terminal No.1 of the airbag control module harness connector IP15 and
the short films of terminal No.2.Please install the short films before installing harness connector.
Note: Do not use a multimeter to measure the driver airbag, otherwise it might set off airbag explosion and cause
serious injuries.
D. Measure the resistance between terminals No.1 and No.2 of the airbag control module harness connector
IP15 and the body ground with a multimeter.
Standard Resistance: 10 kΩ or higher
E. Measure the resistance between terminal No.1 and No.2 of airbag control module harness connector IP15 and
relevant terminals of the airbag harness connector with a multimeter.
Standard Resistance: Less than 1 Ω
F. Measure the resistance between terminal No.1 and terminal No.2 of the airbag control module harness
connector IP15 with a multimeter.
Standard Resistance: 10 kΩ or higher
G. Connect the battery negative cable and wait for at least 2s.
H Turn the ignition switch to ON position.
I Measure the voltage between terminals No.1 and No.2 of the airbag control module harness connector IP15
and the body ground with a universal meter.
Standard Voltage: Less than 1 V
Confirm whether the measured value is accorded with the standard?
4
Inspect the harness between the clock spring and the airbag control module.
A. Disconnect the clock spring harness connector IP41.
B. Measure the resistance between terminal No.1 of harness connector IP41 and terminal No.1 of IP15 with a
universal meter. Measure the resistance between terminal No.2 of harness connector IP41 and terminal No.2
of IP15 with a multimeter (Check for open circuit).
Standard Resistance: Less than 1 Ω
C. Measure the resistance between terminal No.1 and No.2 of IP41 with a multimeter (inspection for short
circuit).
Standard Resistance: 10 kΩ or higher
D. Measure the resistance between terminals No.1&No.2 of harness connector IP41 and the body ground with a
multimeter (Inspect for short circuit to earth).
Standard Resistance: 10 kΩ or higher
E. Connect the battery negative cable and wait for 2s at least. Refer to 2.12.6.1 Battery Cable Disconnection and
No
Yes
Go to step 6