Geely Emgrand X7. Manual part — 431
Geely Emgrand X7. Manual part - 431
Notes:
Some 100PG lubricating oil for the A/C system may be recycled together with the refrigerant. The recyclinged
lubrication oil quantity is indeterminate. The filling machine can separate lubrication oil from refrigerant, so as to
determine the amount of lubrication oil recyclinged. The same amount of lubricating oil should be added when
refilling the system. See the manufacturer's Instructions for learning in detail the use method of the filling
machine.
12. Start Recycling process see the manufacturer's Instructions for learning in detail the use method of the filling
machine.
13. Waiting for 5min, and then inspect pressure gauge on low-pressure side of control panel, if the A/C system
keeps vacuum, and complete Recycling.
Notes:
If the control panel display the refrigerant tank is full in the course of Recycling, close the filling machine, another
empty tank is installed for storing the refrigerant needing to the next step. Forbid using of the other types of
refrigerant tank.
14. If pressure gauge on low-pressure side begins to rise from zero, it indicates that there still has refrigerant in
system. Recycling the rest of the refrigerant. Repeat this step until the system can maintain vacuum for 2min.
The emptying filling machine refrigerant tank must be filled with enough R-134a refrigerants to fill. Inspect
the refrigerant quantity in the tank. If the amount of the refrigerant is less than 3.6kg (8lb), add the new
refrigerant to the refrigerant tank. See the instruction for use of the filling machine for details to learn the
method of adding the refrigerant.
1. Inspect whether high-pressure and low-pressure hose are connected to A/C system. Open high-pressure and
low-pressure valves on control panel of filling machine.
2. Open air valve and liquid on refrigerant reservoir.
Notes:
See the manufacturer's Instructions for learning in detail the use method of the filling machine, you must exhaust
the air from the system thoroughly before you refill with the refrigerant or recycled refrigerant.
3. Start vacuum pump and implement exhaust procedures. In the recycling process, the non-condensable gas
(mostly air) is automatically discharged from the tank. You will hear the pressure relief sound.
Notes:
Regularly replace vacuum pump oi, see the manufacturer's instructions for learning in detail the use method of the
filling machine.
4. Check the system for any leakages; see the manufacturer's instructions for learning in detail the use method
of the filling machine.
Filling and supplement of A/C system lubricating oil
You must supplement with the lubricating oil drained from the A/C system during the recycling process.
1. Use 100PG lubricating oil contained with scale bottle specially used for R-134a system.
2. Refer to the user's manual provided by manufacturer, in which use method of filling machine is explained.
Add 100PG lubricating oil to the system.
3. When filled oil volume reaches requirments, close valve.
Notes:
Remember tightening the lubricating oil bottle cover in order to avoid moisture or pollutant from entering the
lubricating oil. This operation requires the A/C system has a certain degree of vacuum, inhibits opening the
lubricating oil filling valve when the A/C system has positive pressure; otherwise, it will lead to the backflow of
the lubricating oil through the air port of the oil bottle. The oil level shall not be lower than oil suction pipe when
filling or compensating lubrication oil; otherwise, air will enter the A/C system.
Filling
1723
Notes:
Firstly empty the A/C system prior to filling.
1. Close high, low pressure valves on control panel.
2. Close high-pressure side valve on control panel.
3. Refer to User's manual provided by manufacturer to learn application method of filling machine.
4. Fill the A/C with a necessary amount of refrigerant and make sure the amount is measured in the correct unit
(namely kilogram or pound).
5. Start
filling
Refrigerant charging was completed successfully
1. Close high, low pressure valves on control panel of filling machine, both valves must be closed.
2. Start vehicle and A/C system.
3. Keep engine running until the readings of pressure gauge on high-pressure side and low-pressure side are
stable.
4. Compare the readings with the system specifications.
5. Check the evaporator outlet temperature and make sure the operations performed on the A/C system comply
with the system specifications.
6. Keep the A/C in operation.
7. Close the high pressure side quick coupling valve.
8. Disconnect the high pressure side hose from the vehicle.
9. Open the high pressure and low pressure side valves from the control panel. The system will be quickly
absorbed with the refrigerant in the two hoses through low-pressure side hose.
10. Closed low pressure side lower pressure quick connector valve
11. Dismantle low-pressure hose from vehicle.
Unsuccessful for refrigerant charging
Sometimes, the refrigerant entering the A/C system does not reach the total filling quantity. There are two reasons
for resulting in such situation:
1. Pressure of refrigerant can of filling machine is more or less the same as that of A/C system, which will lead
to slow filling process. See the manufacturer's Instructions for learning in detail the use method of the filling
machine.
2. There is no sufficient refrigerant in refrigerant reservoir for filling. Hereto, recycling part of refrigerant
injected from the vehicle, empty the A/C system, add refrigerant to the refrigerant can, and at last, inject
again. See the manufacturer's Instructions for learning in detail the use method of the filling machine.
1724
8.2.8 Dismantle and installation
8.2.8.1 A/C control panel replacement
See 8.3.8.1 Replacement of electric A/C control panel.
8.2.8.2 Ambient air temperature replacement
8.2.8.3 A/C pressure switch replacement
8.2.8.4 Solar sensor replacement
Dismantle procedure
Warning!
See 8.1.1 "warnings for intake of R-134a" in warning and precaution.
1. Disconnect the battery negative cable. Refer
to.11.8.1battery cable disconnection/connection
Procedures.
2. Disconnect harnesses connector of sun sensor
from instrument table.
NL08-0068b
Installation Procedure:
1. Connect to solar sensor harness connector.
2. Install sun sensor onto instrument table.
3. Connect the battery negative cable.
NL08-0069b
1725
8.3 Power A/C
8.3.1 Specifications
8.3.1.1 Fastener specifications
Torque Range
Fastener Name
Model
Metric (N·m)
English system
(lb-ft)
Pipeline system assembly hexagonal flange
face nut
M6 7-8
5-6
Pipeline system assembly hexagonal flange
face bolt
M6×12 10-12
7-9
Pipeline system assembly hexagonal flange
face bolt
M6×20 10-12
7-9
Pipeline system assembly hexagonal flange
face bolt
M6×20 18-20
13-15
Pipeline system assembly hexagonal flange
face bolt
M8×20 16-18
12-13
Compressor assembly hexagon-headed bolt
M8×105
28-30
21-22
Hexagon flange face bolt of condenser
M6×16
6-7
4-5
A/C head unit hexagon nut and spring gasket
assembling unit
M6 6-7
4-5
A/C head unit hexagon flange bolt
M6×12
6-7
4-5
A/C head unit hexagon bolt and spring gasket
assembling unit
M6×12 6-7
4-5
No.1.
No.2 water pipe steel belt type elastic
hoop
- -
-
A/C control panel cross recessed pan head
self-tapping screw and flat gasket assembling
unit
ST4.2×16 3-4.5
2.2-3.3
8.3.1.2 Refrigeration system parameters
Items Item
parameter
Nominal refrigerating capacity/W
≥4500 (rotational speed of compressor is
1800rpm )
Displacement/(ml/r) 180
Model HS18
Compressor
Electromagnetic clutch consumption
power/W
46
Max.air volume/(m3/h)
500
Air Volume Control
Automatic
Blower
Motor consumption power/W
250
Condenser
Size /mm
68×422×731
1726