Geely EC718, EC718RV, EC715, EC715RV. Manual part — 412
Geely EC718, EC718RV, EC715, EC715RV. Manual part - 412
11.5.5 Disassemble View
11.5.5.1 Disassemble View
Window Regulator Assembly
3
1
2
FE11-2006b
Legend
1. Window Motor
2. Window Regulator Rail
3. Electric Window
Body Electric
Glasses / Windows / Mirrors
11-161
Outside Rearview Mirror Assembly
1
2
3
4
5
FE11-2007b
Legend
1. Electric Outside Rearview Mirror Turn Signal Lamp
2. Outside Rearview Mirror Cover
3. Outside Rearview Mirror Adjust Motor Bracket
4. Outside Rearview Mirror Adjust Motor
5. Outside Rearview Mirror Adjust Motor Glass (With
Heating Wire)
11-162
Glasses / Windows / Mirrors
Body Electric
11.5.6 Schematic
11.5.6.1 Schematic
Schematic With Express Down (If Equipped)
Window Switch: Up/Down/Automatic
To BCM
Protective
Circuit
Relay
Input
Circuit
Hall IC
FE11-2008b
Body Electric
Glasses / Windows / Mirrors
11-163
11.5.7 Diagnostic Information and Procedures
11.5.7.1 Diagnosis Description
Refer to
get familiar with the system functions and operation before start system diagnostics, so
that it will help to determine the correct diagnostic steps, more importantly, it will also help to determine whether the customer
described situation is normal.
11.5.7.2 Visual Inspection
–
Check installed aftermarket equipments that may affect the power windows and power mirrors operations.
–
Check the easy to access system components to identify whether there is a significant damage or potential malfunction.
–
Check whether the window initialization failed.
11.5.7.3 Control Module Diagnostic Information
Power window control module reports the following failures through the LIN bus:
–
Motor / Relay Malfunction
–
Hall Sensor Malfunction
–
Thermal Protection Triggered
–
Up Button Is Pressed
–
Down Button Is Pressed
11.5.7.4 Glass Regulator Initialization (If Window Express Down Feature Is Available)
–
To initialize the system, the glass must be up all the way to the top, and the switch is pressed to lift the window glass until the
control module stops the glass motor (within 1s after the glass reaches the top). Each time the system lost initialization, repeat
these steps to restore the window express down function.
–
Initialization, all system functions must be operational.
–
Initialization, the control module voltage should not drop to below 9 V.
–
When the control module supply voltage drops momentarily, but the voltage is still higher than 6V, the initialization is effective.
–
Every time the glass is lift to the top till stop using automatic mode (at the top position); system will obtain the latest top position
and overwrite the previous value to calculate the top position.
Note
–
Only when the new value is in the calibrated value range, it overwrites the original value, otherwise the control
module will ignore the new value.
–
If the initialization process has not been implemented or have been lost, system does not provide automatic up,
express down and comfort closing function. Manual up, down and auto-down feature can be operated.
In the following circumstances, the initialization will be lost (If window express down is available is equipped)
–
Power supply is cut off.
–
When the glass is moving up, the power supply voltage drops below 6 V.
–
Control module can not detect logical Hall sensor signals.
–
Window glass moves to a location outside the operating range.
11-164
Glasses / Windows / Mirrors
Body Electric