Geely EC718, EC718RV, EC715, EC715RV. Manual part — 163
Geely EC718, EC718RV, EC715, EC715RV. Manual part - 163
1
2
3
Generator Harness Connector EN07
Instrument Cluster Harness Connector IP03
15 14
12
10 9 8 7 6 5 4 3 2 1
16
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
FE02-9409b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Remove the instrument cluster, Disconnect the instrument
cluster wiring harness connector IP03.
(d)
Check the continuity between instrument cluster wiring
harness connector IP03 and generator harness connector
EN07 terminal No.1.
(e)
Measure resistance between generator harness connector
EN07 terminal No.1 and a reliable ground.
Standard Resistance Value:
Test Items
Standard Value Value
Continuity Between IP03
(13) and EN07 (1)
<1 Ω
Resistance Between EN07
(1) and A Reliable Ground
<1 Ω
(f)
Connect generator harness connector EN07.
(g)
Connect instrument cluster harness connector IP03, and
install the instrument cluster.
Is the resistance specified value?
No
Repair the faulty part. Confirm the fault has
been fixed.
Yes
Step 4
Replace the instrument cluster. Confirm the fault has been fixed.
Step 5
Check the generator regulator power supply circuit.
1
2
3
Generator Harness Connector EN07
FE02-9410b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Measure voltage between generator harness connector
EN07 terminal No.3 and a reliable ground.
Standard Voltage: 11-14 V
(d)
Connect generator harness connector EN07.
Is the voltage specified value?
No
Generator regulator power circuit is open.
Repair the faulty part. Confirm the fault has
been fixed.
Yes
Step 6
Check the generator regulator excitation power supply.
Engine
Starting / Charging System JL4G18-D
2-567
1
2
3
Generator Harness Connector EN07
FE02-9411b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Measure voltage between generator harness connector
EN07 terminal No.2 and a reliable ground.
Standard Voltage: 11-14 V
(d)
Connect generator harness connector EN07.
Is the voltage specified value?
No
Yes
Step 7
Replace the generator. Refer to
Step 8
Are Instrument cluster, electric windows, air-conditioning system working properly?
No
Relay IG1 does not provide IG1 power. Check
the IG1 relay.
Yes
Step 9
The circuit between EN07 terminal No.2 and instrument cluster fuse IF25 is open. Check and repair the faulty
part.
Next
Step 10
Diagnostic completed.
2.11.7.7 Charging Indicator Always Off
Step 1
Connect the ignition switch, and keep the engine off, is battery charging indicator on?
No
Intermittent Fault. Refer to
Yes
Step 2
Disconnect generator harness connector EN07, is battery charging indicator on?
No
Yes
Step 3
Check the generator regulator power supply circuit.
Refer to
Step 4.
Is the voltage specified value?
2-568
Starting / Charging System JL4G18-D
Engine
No
The generator regulator power circuit is open.
Repair the faulty part. Confirm the fault has
been fixed.
Yes
Step 4
Check the generator regulator excitation power supply.
Refer to
Step 5.
Confirm the fault has been fixed.
No
Yes
Step 5
Replace the generator. Confirm the fault has been fixed.
Step 6
Are other instrument lights and indicators working properly?
No
Yes
Step 7
Replace the instrument cluster. Refer to
Step 8
Check the instrument power circuit and ground circuit. Refer to
.
Next
Step 9
Diagnostic completed.
2.11.7.8 Generator Noise Diagnosis
Diagnostic Tips:Generator noise may be caused by electrical or mechanical noise. Electrical noise (electromagnetic hum sound) is
usually added to the generator with the electrical load changes, which is the normal operating characteristics of all generators. During
the service, pay attention to distinguish, otherwise it will cause unnecessary customer complaints. When diagnose the generator
mechanical noise, firstly check whether there are loose generator components or interference. In some cases even if the sound in
engine compartment is light, it can enter into the passenger compartment. If this is the case, replacing the generator does not solve
the problem, which leads to misjudgments.
Step 1
Keep the generator not working, and confirm whether the noise disappears.
(a)
Start the engine, verify that the noise can be heard.
(b)
Shut down the engine.
(c)
Disconnect the generator from the generator on the wiring
harness connector EN07.
(d)
Start the engine.
Confirm whether the noise disappears?
Yes
Engine
Starting / Charging System JL4G18-D
2-569
No
Step 2
Check the generator shaft.
(a)
Shut down the engine.
(b)
Remove the drive belt.
(c)
Rotate the generator pulley by hand.
Does the generator rotate smoothly without catching and
grinding noise?
Yes
No
Step 3
Reinstall the generator.
Remove and install the generator. Tighten the generator retaining
bolts to the specified torque. Refer to
. Start the engine, does the noise disappear?
Yes
System normal
No
Step 4
Is the drive belt loose?
Yes
No
Step 5
Compare with a known good vehicle, is the noise the same?
Yes
System normal
No
Step 6
Replace the generator.
Important Note
If a clear generator fault has not been found, make sure that all
other possible noise sources have been excluded and then replace
the generator.
If the noise is part of the normal generator characteristics, after
replacing generator the noise will not disappear.
Yes
Troubleshooting
Step 7
Replace the drive belt or the drive belt tensioner.
Refer to
2-570
Starting / Charging System JL4G18-D
Engine