Geely EC718, EC718RV, EC715, EC715RV. Manual part — 49
Geely EC718, EC718RV, EC715, EC715RV. Manual part - 49
3. Schematic:
12
13
From Battery
Main Relay
Pre-catalytic Oxygen Sensor
To Post-catalytic Oxygen Sensor
Engine
Control
Module
FE02-5008b
4. Diagnostic Steps:
Step 1
Connect scan tool.
Next
Step 2
Start engine and turn on the scan tool.
Next
Step 3
Maintain engine speed at 2,500 rpm for more than 2 min to warm up the engine, until the engine coolant
temperature reaches 80°C (176 ºF).
Next
Step 4
Select on scan tool: Engine/Read data stream/group 1 oxygen sensor voltage 1 (Pre-Catalytic oxygen
sensors).
Next
Step 5
Observe the oxygen sensor output voltage, the data should fluctuate within 0.1-0.8 V.
Engine
Control System JL4G18-D
2-111
Yes
Intermittent Fault. Refer to
No
Step 6
Test the oxygen sensor signal.
(a)
If the voltage data is consistently below 0.45 V (mixture too
lean), then carry out inspection steps as following:
•
Spray proper amount of propane gas into the intake port.
•
Inspect whether the pre-catalytic oxygen sensor voltage
data has a significant change, in which case the signal
voltage will increase rapidly.
(b)
If the voltage data is consistently higher than 0.45 V (mixture
too rich), then carry out inspection steps as following:
•
Put gear into Neutral.
•
Apply hand brake.
•
Press the accelerator pedal so the engine speed
suddenly increases to 4,000 rpm and then quickly release
the accelerator pedal.
•
Repeat the previous steps more than 3 times.
•
Inspect whether the pre-catalytic oxygen sensor voltage
data has a significant change, in which case the signal
voltage will decrease rapidly.
During the above test, the pre-catalytic oxygen sensor signal
voltage should change significantly.
Is voltage changed significantly?
Yes
Inspect the cause for engine air-fuel ratio too
lean/too rich. Refer to
.
No
Step 7
Check and confirm no other control system DTC codes.
(a)
Connect scan tool to a datalink connector.
(b)
Turn the ignition switch to "ON" position.
(c)
Press the scan tool power button.
(d)
Select the following menu items: Engine/Read DTC codes.
(e)
Read DTC codes.
Results:
DTC Codes Shown
To Step
DTC codes other than P0030, P0031, P0032,
P0053
No
P0030, P0031, P0032, P0053
Yes
No
2-112
Control System JL4G18-D
Engine
Yes
Step 8
Measure pre-catalytic oxygen sensor signal circuit.
FE02-5043b
1
2
3
4
Pre-catalytic Oxygen Sensor
Harness Connector EN02
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect oxygen sensor wiring harness connector EN02.
(c)
Turn the ignition switch to "ON" position.
(d)
Measure voltage between Pre-Catalytic oxygen sensor
wiring harness connector EN02 terminal No.4 and a reliable
ground.
Standard Voltage: 0.35-0.5 V
(e)
Connect the pre-catalytic oxygen sensor wiring harness
connector EN02.
Is voltage the specified value?
No
Yes
Step 9
Measure the pre-catalytic oxygen sensor ground circuit.
FE02-5044b
1
2
3
4
Pre-catalytic Oxygen Sensor
Harness Connector EN02
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect oxygen sensor wiring harness connector EN02.
(c)
Turn the ignition switch to "ON" position.
(d)
Measure resistance between pre-catalytic oxygen sensor
connector EN02 terminal No.3 and a reliable ground.
Standard Resistance: Less than 1 Ω
(e)
Connect pre-catalytic oxygen sensor wiring harness
connector EN02.
Is resistance the specified value?
No
Yes
Step 10
Replace the pre-catalytic oxygen sensor. Refer to
Pre-Catalytic Oxygen Sensor Replacement
.
Next
Step 11
Check the pre-catalytic oxygen sensor signal circuit.
Engine
Control System JL4G18-D
2-113
FE02-5045b
1
3
5
7
8
6
4
2
9
10
11
12
13
23
24
25
26
27
28
29
30
37
51
52
53
54
55
56
57
58
59
60
61
62
63
64
38
39
40
41
42
43
44
45
46
47
48
49
50
31
32
33
34
35
36
14
15
16
17
18
19
20
21
22
1
2
3
4
Pre-catalytic Oxygen Sensor
Harness Connector EN02
ECM Harness Connector EN01
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect oxygen sensor wiring harness connector EN02.
(c)
Disconnect ECM harness connector EN01.
(d)
Measure resistance between pre-catalytic oxygen sensor
wiring harness connector EN02 terminal No.4 and ECM
harness connector terminal No.45. Check whether the circuit
is open. If there is no open circuit, repair the faulty part.
(e)
Measure resistance between pre-catalytic oxygen sensor
wiring harness connector EN02 terminal No.4 and a reliable
ground. Check whether the circuit is short to ground. If there
is no short circuit, repair the faulty part.
(f)
Measure voltage between Pre-Catalytic oxygen sensor
wiring harness connector EN02 terminal No.4 and a reliable
ground. Check whether the circuit is short to power supply. If
there is no short circuit, repair the faulty part.
Test Items
Standard Value
Resistance Between EN02 (4) and EN01
(45)
Less than 1 Ω
Resistance Between EN02 (4) and a
Reliable Ground
10 kΩ or higher
Voltage Between EN02 (4) and a Reliable
Ground
0 V
Normal
Step 12
Check the pre-catalytic oxygen sensor ground circuit.
2-114
Control System JL4G18-D
Engine
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.