Lexus ES300 (2002 year). Manual — part 204
HOUSING PART NUMBER LIST
E–64
378
Wire Harness Repair Manual (RM1022E)
Part No. of
Connector
Body
Memo
Sleeve
Color
Part No. of Repair Wire
Sealing
Ability
Cav. No.
Male
Female
Terminal
Supply
Part No. of
Connector
Body
Memo
Sleeve
Color
500 mm
Type
160 mm
Type
Sealing
Ability
Cav. No.
Male
Female
Terminal
Supply
90980–
82998–
82998–
12273
X
1.0 III
F
6
U
12690*
–
L
12273
X
2.3 II
F
6
U
12340*
–
L,Y
12274
X
1.0 III
F
18
U
12690*
–
L
12274
X
2.3 II
F
18
U
12340*
–
L,Y
12275
X
1.0 III
F
8
U
12690*
–
L
12275
X
2.3 II
F
24
U
12340*
–
L,Y
12276
X
1.0 III
F
24
U
12690*
–
L
12276
X
2.3 II
F
14
U
12340*
–
L,Y
12277
X
1.0 III
F
10
U
12690*
–
L
12277
X
2.3 II
F
20
U
12340*
–
L,Y
4.8
1
12380
–
Y
12278
X
1.0 III
F
6
U
12690*
–
L
2.3 II
18
12340*
–
L,Y
12291
X
1.0 III
M
39
U
–
–
–
PCB
12296
X
0.64
F
3
U
12750*
–
L
Lever
Lever
B–47
TERMINAL AND CONNECTOR REPAIR–HOW TO INSTALL AND REMOVE SPECIAL CONNECTORS
57
Wire Harness Repair Manual (RM1022E)
HOW TO INSTALL AND REMOVE SPECIAL CONNECTORS
Low Fit and Lever Type Connector
[Case 1]
1.
Cut the connection of the connector
(1)
Push the place indicated by the arrow.
(2)
The lock is released and lever is lifted up.
(3)
Lift the lever up until it stops.
an
(4)
Cut the connection of the connector.
NOTICE:
Do not hold the wire harness to pull it.
2.
Connect the connector
(1)
Connect the connector in the condition that the lever
is fully lifted up.
HINT:
If the lever is locked at the lower position, follow
the procedure [Case 1]. (1) to (3) and lift the lever up fully.
Lever
Lever is not locked
Lever
TERMINAL AND CONNECTOR REPAIR–HOW TO INSTALL AND REMOVE SPECIAL CONNECTORS
B–48
58
Wire Harness Repair Manual (RM1022E)
(2)
Hold the connector to prevent it from slip off and push
it down until you hear a click to lock it.
(3)
Confirm that the lever is securely locked.
[Case 2]
1.
Cut the connection of the connector
(1)
Hold the area indicated by the arrow in the illustration
(2)
The lock is released and the lever is lifted up.
(3)
Lift the lever up fully.
(4)
Cut the connection of the connector.
NOTICE:
Do not hold the wire harness to pull it.
Lever
Lever is not locked
Lever
B–49
TERMINAL AND CONNECTOR REPAIR–HOW TO INSTALL AND REMOVE SPECIAL CONNECTORS
59
Wire Harness Repair Manual (RM1022E)
2.
Connect the connector
(1)
Connect the connector in the condition that the lever
is fully lifted up.
(2)
Hold the connector to prevent it from slip off and push
it down until you hear a click to lock it.
(3)
Confirm that the lever is securely locked.
[Case 3]
1.
Cut the connection of the connector
(1)
Pick the part indicated in the illustration by fingers.
(2)
The lock is released and the lever is lifted up.
(3)
Lift the lever up fully.