Lexus GS300/400 (2000 year). Manual — part 122
CO0AH–01
B00921
B00920
B00919
–
COOLING (2JZ–GE)
ELECTRIC COOLING FAN
CO–29
1567
REASSEMBLY
1.
INSTALL FAN MOTORS
(a)
Install the fan motor with the 3 screws. Install the 2 fan mo-
tors.
(b)
Install the wires and connector holders to the fan shroud
as shown in the illustration.
2.
INSTALL FANS
Install the fan with the nut. Install the 2 fans.
CO09Y–01
A02724
Air Cleaner Inlet
Upper Radiator Support
MAF Meter Connector
Air Cleaner and MAF
Meter Assembly
Lower Radiator Hose
Radiator
Assembly
ECM Outlet Duct
ECT
Switch
Engine Wire Clamp
EVAP Hose
Lower Radiator Support
Intake Air Resonator
PS Pump
Front Bracket
Water Pump Pulley
Drive Belt
Engine Under Cover
PS Vane Pump
Oil Cooler Hose
for A/T
Electric Cooling
Fan Connector
Upper Radiator
Hose
x 18
58 (590, 43)
52 (530, 38)
N·m (kgf·cm, ft·lbf)
Non–reusable part
: Specified torque
Wire Clamp
Upper Radiator
Support
–
COOLING (2JZ–GE)
WATER PUMP
CO–3
1541
WATER PUMP
COMPONENTS
B01985
Water Bypass Outlet
O–Ring
Engine Wire
Water
Pump
Connector Bracket
Idler Pulley
Gasket
Timing Belt Guide
No.2 Water Bypass Pipe
Drain Hose
Timing Belt Tensioner
Timing Belt
Drive Belt Tensioner
Oil Filler Cap
No.3 Timing Belt Cover
No.1 Water
Bypass Pipe
Gasket
Crankshaft Pulley
Dust Boot
x 5
Thermostat
O–Ring
O–Ring
No.2 Timing Belt Cover
Gasket
No.1 Timing Belt Cover
Gasket
Water Inlet
x 6
35 (350, 26)
21 (210, 15)
21 (210, 15)
27 (270, 20)
N·m (kgf·cm, ft·lbf) : Specified torque
Non–reusable part
Precoated part
330 (3,300, 243)
Clamp Bracket
Crankshaft Position
Sensor Connector
Gasket
CO–4
–
COOLING (2JZ–GE)
WATER PUMP
1542
CO0AI–03
B02071
CO–30
–
COOLING (2JZ–GE)
ELECTRIC COOLING FAN
1568
INSTALLATION
1.
INSTALL ELECTRIC COOLING FAN
(a)
Install the electric cooling fan with the 6 bolts.
Torque: 5.0 N·m (50 kgf·cm, 44 in.·lbf)
(b)
Connect the upper radiator hose to the radiator.
(c)
Connect the ECM outlet duct to the ECM box.
(d)
Connect the wire for electric cooling fan to clamp on the
electric cooling fan.
(e)
Connect the 2 electric cooling fan connectors.
(f)
Connect the radiator reservoir hose to the radiator.
2.
INSTALL AIR CLEANER AND MAF METER AS-
SEMBLY
3.
INSTALL AIR CLEANER INLET
4.
FILL WITH ENGINE COOLANT
5.
START ENGINE AND CHECK FOR COOLANT LEAKS
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.