Lexus ES300 (1997 year). Manual — part 265
Z19375
Ignition Switch
Instrument Panel Junction Block
GAUGE Fuse
POWER Fuse
DOOR Fuse
Power Main Relay
Integration Relay
Sliding Roof Switch
Sliding Roof Control Relay
Sliding Roof Motor
LImit Switch
Engine Room Junction Block
DOME Fuse
BE05Q–01
BE–124
–
BODY ELECTRICAL
SLIDING ROOF SYSTEM
1508
1997 LEXUS ES300 (RM511U)
SLIDING ROOF SYSTEM
LOCATION
BE05R–01
N21643
Wire Harness Side
1 2
3
4
5 6 7
8
s–8–1
N21993
1
2
N21994
2
1
–
BODY ELECTRICAL
SLIDING ROOF SYSTEM
BE–125
1509
1997 LEXUS ES300 (RM511U)
INSPECTION
1.
INSPECT SLIDING ROOF CONTROL RELAY AND
SWITCH CIRCUIT
Disconnect the connector from the relay and switch and inspect
the connector on the wire harness side, as shown in the chart.
Tester connection
Condition
Specified condition
1 – 5
Constant
Continuity
2 – Ground
Constant
Continuity
3 – Ground
No.1 limit switch OFF (Sliding roof closed)
No continuity
3 – Ground
No.1 limit switch ON (Sliding roof opened)
Continuity
7 – Ground
No.2 limit switch OFF (Sliding roof tilted up or
open approx. 200 mm (7.87 in.))
No continuity
7 – Ground
No.2 limit switch ON (Except for conditions
mentioned above)
Continuity
4 – Ground
Ignition switch LOCK or ACC
*No voltage
Ignition switch ON
Battery positive voltage
*Exceptions: For 60 seconds after the ignition switch is turned
ON
→
OFF (ACC) or until driver or passenger door is opened
after the ignition switch is turned ON
→
OFF (ACC).
If the circuit is as specified, replace the relay and switch.
2.
INSPECT SLIDING ROOF MOTOR OPERATION
(a)
Connect the positive (+) lead from the battery to terminal
1 and the negative (–) lead to terminal 2, check that the
motor turns counterclockwise (moves of the close and up
side).
(b)
Reverse the polarity, check that the motor turns clock-
wise. (moves of the open and down side).
If operation is not as specified, replace the motor.
N21180
ON
OFF
No.1
Limit Switch
No.2
Limit Switch
1
2
3
4
5
6
N21553
Wire Harness Side
1
2
3 4
5 6
g–6–1–B
N21644
within
10 to 60
seconds
BE–126
–
BODY ELECTRICAL
SLIDING ROOF SYSTEM
1510
1997 LEXUS ES300 (RM511U)
3.
INSPECT SLIDING ROOF LIMIT SWITCH CONTINUITY
Switch position
Tester connection
Specified condition
No.1 limit switch OFF
(SW pin released)
4 – 5
No continuity
No.1 limit switch ON
(SW pin pushed in)
4 – 5
Continuity
No.2 limit switch OFF
(SW pin released)
4 – 6
No continuity
No.2 limit switch ON
(SW pin pushed in)
4 – 6
Continuity
If continuity is not as specified, replace the switch.
4.
INSPECT SLIDING ROOF MOTOR AND LIMIT SWITCH
CIRCUIT
Disconnect the connector from the limit switch and inspect the
connector on the wire harness side.
Tester connection
Condition
Specified condition
3 – Ground
Constant
Continuity
4 – Ground
Constant
Continuity
If the circuit is not as specified, inspect the circuits connected
to other parts.
5.
INSPECT CIRCUIT BREAKER OPERATION
(a)
With the sliding roof in the fully opened position, hold the
sliding roof switch in ”OPEN” position and check that
there is a circuit breaker operation noise within 10 to 60
seconds.
N21645
within
60
seconds
–
BODY ELECTRICAL
SLIDING ROOF SYSTEM
BE–127
1511
1997 LEXUS ES300 (RM511U)
(b)
With the sliding roof in fully opened position, hold the slid-
ing roof switch in ”TILT UP” position and check that the
sliding roof begins to close within 60 seconds.
If operation is not as specified, replace the motor.
6.
INSPECT KEY–OFF SLIDING ROOF OPERATION
(See integration relay circuit on page
)
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.