Mercedes-Benz ML320. Manual — part 659
The series resistor assembly (R14) is comprised of three resistors which can be interconnected, via series
connection, to form an overall resistor. Depending on the setting of the blower switch, current is guided via the
resistors assigned to the set blower level to the blower (M2). Different control voltages are therefore present at
the blower (M2), as a result of which the blower (M2) operates at different rotational speeds.
COMBINATION FILTER, LOCATION/TASK/DESIGN/FUNCTION - GF83.10-P-2128GI
MODEL 163 as of 1.9.01 with CODE (580a) Automatic air conditioning
Fig. 20: Identifying Combination Filter
FOOTWELL FLAP ACTUATOR MOTOR, FUNCTION - GF83.10-P-2132-02GI
Pin assignment of series resistor assembly
R14
Assigned
resistor
Blower switch
setting
Blower (M2) control
voltage
Pin 1
R3
Blower level 3
10V
Pin 2
R2+R3
Blower level 2
8V
Pin 3
R1+R2+R3
Blower level 1
4V
Pin 4
None
Blower level 4
12V
Combination
filter location
The combination filter (1) is at the bottom of the automatic air conditioning box.
Combination
filter task
The combination filter (1) removes impurities and odors from the air flowing through
the automatic air conditioning box. Fresh air and recirculating air are filtered.
Combination
filter design
The combination filter (1) consists of fleece and a large number of so-called sliver
absorbers that are evenly distributed over an air-permeable carrier mat.
Combination
filter function
The combination filter (1) filters over 80% of particles from 0.3 in size and up to
100% of 0.5 u sized particles and pollen. The sliver adsorbers also continuously
absorb odors and pollutants and release them again in extremely small concentrations
after a certain time.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Function
Rotating the air distribution switch in the AAC push-button control module (N22) actuates the footwell flap
actuator motor via the AC bus. The footwell flap actuator motor (M2/21) controls the footwell flap, which
adopts the following positions according to requirements.
Switching logic
footwell flap closed = 0%
footwell flap open = 100%
Automatic footwell flap control (Auto button engaged)
The footwell flap is opened depending on the following values
blending air flap setting
Coolant temperature
Evaporator temperature
linear up to 100 % open.
Footwell flap control via push-button control module
(Clock type switch setting of air distribution switch)
If a problem exists, it is possible to retrieve and verify the defined end positions by means of the diagnosis
assistant system (DAS) (valuation trip).
After replacing an actuator motor an adjustment run must be performed via the Diagnosis Assistant System
(DAS), i.e. the flap OPEN and SHUT limit positions are defined and retained.
FOOTWELL FLAP ACTUATOR MOTOR, LOCATION / TASK / FUNCTION - GF83.10-P-2132GI
MODEL 163 as of 1.9.01 with CODE (580a) Automatic air conditioning
1 o'clock
2 o'clock
3 o'clock
4 o'clock
5 o'clock
6 o'clock
17%
32%
50%
68%
85%
100%
7 o'clock
8 o'clock
9 o'clock
10 o'clock
11 o'clock
12 o'clock
66%
31%
0%
%
0%
0%
NOTE:
All actuator motors are identical.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Fig. 21: Identifying Footwell Flap Actuator Motor
AIR INLET, LOCATION/FUNCTION - GF83.10-P-2138GC
MODEL 163, 168
AIR DUCTS, LOCATION/TASK/DESIGN - GF83.10-P-2139GH
MODEL 163
Footwell flap actuator
motor, location
The footwell flap actuator motor (M2/15) is on the left on the
automatic air conditioning box.
Footwell flap actuator
motor, task
The footwell flap actuator motor operates the footwell flap for
regulating the air flow to the front footwell.
Footwell flap actuator
motor, function
GF83.10-P-
2132-02GI
Air inlet, location
Model 168
GF83.10-P-2100-01GC
Model 163
GF83.10-P-2100-01GH
Air inlet, function
The fresh air required for
ventilation flows through
the air inlet to the
heater/air conditioning
housing.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Design shown up to 31.08.01
Fig. 22: Identifying Air Ducts - Design Shown Up To 31.08.01
BLOWER REGULATOR, LOCATION / TASK / FUNCTION - GF83.10-P-2141GI
MODEL 163 as of 1.9.01 with CODE (580a) Automatic air conditioning
Air duct
locations
up to 31.08.01
GF83.10-P-
2101-01GH
as of 1.09.01
GF83.10-P-
2101-01GI
Air ducts
task
The air ducts (1-5) lead the air that is required to ventilate the vehicle
from the heater/ evaporator housing to the air vents in the vehicle
interior.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me