Mercedes-Benz ML320. Manual — part 355
Fig. 10: Checking Voltage Regulator (Chassis 163)
Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
DIODE TEST
2001 Mercedes-Benz ML320
2001-04 STARTING & CHARGING SYSTEMS Generators & Regulators - 163 Chassis
me
Connect DC clip-on probe from engine tester with oscilloscope to positive battery terminal. See Fig. 11 . Start
engine. Switch on low beam. Access diode test at 3000 RPM. See Fig. 12 -Fig. 14 . Replace generator as
necessary.
2001 Mercedes-Benz ML320
2001-04 STARTING & CHARGING SYSTEMS Generators & Regulators - 163 Chassis
me
2001 Mercedes-Benz ML320
2001-04 STARTING & CHARGING SYSTEMS Generators & Regulators - 163 Chassis
me
Fig. 11: Identifying Oscilloscope Connection
Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
Fig. 12: Identifying Oscilloscope Patterns (No Fault Indicated)
Courtesy of MERCEDES-BENZ OF NORTH AMERICA.
2001 Mercedes-Benz ML320
2001-04 STARTING & CHARGING SYSTEMS Generators & Regulators - 163 Chassis
me
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.