Mercedes-Benz ML320. Manual — part 656
Fig. 4: Identifying Air Duct (Up To 31.08.01)
AIR DUCT LOCATIONS - GF83.10-P-2101-01GI
The lateral nozzle and side window defroster nozzle (3) air ducts are on the left and right below the instrument
panel.
The windshield defroster nozzle air duct (2) is on top of the evaporator housing (front center) below the
instrument panel.
The center nozzle air duct (1) is on top of the evaporator housing behind the center nozzle.
The front footwell air duct (4) is integrated in the heater/evaporator housing.
The rear compartment air duct (5) is located below the center console.
The rear footwell air duct (6) is at the bottom next to the rear blower behind the center console.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Fig. 5: Identifying Air Duct (As Of 1.09.01)
BLOWER, LOCATION - GF83.10-P-2102-01GH
The blower (M2) is below the instrument panel to the bottom right of the heater box/evaporator housing (3).
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Fig. 6: Identifying Blower And Heater Box/Evaporator Housing
BLOWER, FUNCTION - GF83.10-P-2102-02GH
Function
Different control voltages are provided at the blower (M2) via the series resistors depending on the blower
switch setting. This produces different blower (M2) speeds.
BLOWER, LOCATION / TASK / DESIGN / FUNCTION - GF83.10-P-2102GC
MODEL 163 up to 31.8.01, 168
BLOWER CONTROLLER FUNCTION - GF83.10-P-2103-01GI
Function
The blower switch passes on a control voltage (0 - 6 V) to the blower regulator (A32n1) via the AAC push-
button control module (N22) and the AC bus. Depending on the control voltage which is present, this then
regulates the blower motor operating voltage (0 - 12 V). This facilitates blower speed control of 0-100 %.
The Auto button can also be used to select
(
) automatic mode.
Pin assignment of series resistor assembly
R14
Assigned
resistor
Blower switch
setting
Blower (M2) control
voltage
Pin 1
R3
Blower level 3
10V
Pin 2
R2+R3
Blower level 2
8V
Pin 3
R1+R2+R3
Blower level 1
4V
Pin 4
None
Blower level 4
12V
Blower,
location
Model 168
GF83.10-P-
2102-01GC
Model 163
GF83.10-P-
2102-01GH
Blower,
task
In fresh air mode the blower (M2) draws in fresh air, and in recirculating air
mode it draws in air from the vehicle interior into the heater or evaporator
housing via the recirculating air flap.
Blower
design
The blower (M2) is designed as a twin-pipe radial blower.
Blower,
function
Model 168
GF83.10-P-
2102-02GC
Model 163
GF83.10-P-
2102-02GH
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
The blower regulator then controls the blower motor operating voltage, depending on the actual measured in-car
temperature and the selected target temperature
(0-12 V). This facilitates blower speed control of 0-100 %.
DUST FILTER, LOCATION - GF83.10-P-2104-01GH
The dust filter (1) is behind the instrument panel bottom section at the passenger side in the heater/evaporator
housing.
Fig. 7: Identifying Dust Filter
REAR VENTILATION, FUNCTION - GF83.10-P-2105-01GC
Function
The louvered-type flaps in the rear vent open from the pressure of the air flowing through the vehicle and allow
it to exit.
If a vacuum is present in the vehicle, as happens when driving with a window or the sliding roof open, the flaps
close automatically due to the force of gravity. This prevents exhaust gases, dust and moisture from being
sucked in.
REAR VENTILATION, LOCATION - GF83.10-P-2105-02GH
The rear vents (1) are located on the left and right behind the rear bumper.
2001 Mercedes-Benz ML320
1998-2005 HVAC Climate Control - 163 Chassis
me
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст