Mazda 6. Manual — part 386
U–48
CONTROL SYSTEM
1C
Blower motor
control signal
Power MOS FET
Fan switch is OFF
Below 1.0
• Inspect terminal voltage of
climate control unit (1A)
Fan switch is at manual
LO
4.1
Fan switch is at manual
HI
7.9
1D
—
—
—
—
—
1E
Rear window
defroster SW
signal
Rear window
defroster relay
Rear window defroster
switch is off
12
• Inspect for continuity or
short circuit (Climate control
unit—rear window defroster
relay: 1E—E)
• Inspect rear window
defroster relay
Rear window defroster
switch is on
Below 1.0
• Inspect terminal voltage of
climate control unit (1H, 1L)
• Inspect audio switch panel
1F
On-board
diagnostic signal
A/C check
connector
Terminal A of A/C check
connector is shorted.
Below 1.0
• Inspect for continuity
(Climate control unit—A/C
check connector: 1F—A)
Other
5.4
• Inspect short circuit (Climate
control unit—A/C check
connector: 1F—A)
• Inspect terminal voltage of
climate control unit (2H, 2L)
1G
—
—
—
—
—
1H
—
—
—
—
—
1I
GND
• Cabin
temperature
sensor
• Evaporator
temperature
sensor
• Ambient
temperature
sensor
• Water
temperature
sensor
• Air mix actuator
• Airflow mode
actuator
Under any condition
Below 1.0
• Inspect terminal voltage of
climate control unit (2L)
1J
—
—
—
—
—
1K
Ambient
temperature
sensor input
Ambient
temperature sensor
Depends on temperature
surrounding sensor
See Figure
2
• Inspect for continuity
(Climate control unit—
ambient temperature
sensor: 1K—B, 1I—A)
• Inspect for short circuit
(Climate control unit—
ambient temperature
sensor: 1K—B)
• Inspect ambient
temperature sensor
• Inspect terminal voltage of
climate control unit (2H, 2L)
1L
—
—
—
—
—
1M
Cabin
temperature
sensor input
Cabin temperature
sensor
Depends on temperature
surrounding sensor
See Figure
3
• Inspect for continuity
(Climate control unit— cabin
temperature sensor: 1M—B,
1I—A)
• Inspect for short circuit
(Climate control unit— cabin
temperature sensor: 1M—B)
• Inspect cabin temperature
sensor
• Inspect terminal voltage of
climate control unit (2H, 2L)
1N
—
—
—
—
—
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action
CONTROL SYSTEM
U–49
U
1O
Water
temperature
sensor input
Water temperature
sensor
Depends on temperature
surrounding sensor
See Figure
4
• Inspect for continuity
(Climate control unit—water
temperature sensor: 1O—A,
1I—B)
• Inspect for short circuit
(Climate control unit—water
temperature sensor: 1O—A)
• Inspect water temperature
sensor
• Inspect terminal voltage of
climate control unit (2H, 2L)
1P
A/C Refrigerant
pressure switch
Fan switch at OFF
12
• Inspect for continuity or
short circuit (Climate control
unit—refrigerant pressure
switch: 1P—A (Dual-
pressure type), 1P—C
(Triple-pressure type))
(Refrigerant pressure
switch—PCM: B—1AC)
• Inspect refrigerant pressure
switch
• Inspect PCM terminal
voltage (1AC)
(See
)
Fan switch at 1st
position, A/C switch ON
Below 1.0
• Inspect terminal voltage of
climate control unit (2H, 2L)
1Q
Evaporator
temperature
sensor input
signal
Evaporator
temperature sensor
Depends on temperature
surrounding sensor
See Figure
1
• Inspect for continuity
(Climate control unit—
evaporator temperature
sensor: 1Q—A, 1I—B)
• Inspect for short circuit
(Climate control unit—
evaporator temperature
sensor: 1Q—A)
• Inspect evaporator
temperature sensor
• Inspect terminal voltage of
climate control unit (2H, 2L)
1R
—
—
—
—
—
1S
Solar radiation
sensor input
Solar radiation
sensor
Incandescent light (60W)
shining on solar
radiation sensor from
distance of approx.
100mm {3.9 in}
4.0
• Inspect for continuity or
short circuit (Climate control
unit—solar radiation sensor:
1S—B, 1B—A)
• Inspect terminal voltage of
climate control unit (1B)
• Inspect solar radiation
sensor
Light to solar radiation
sensor block
Below 1.0
1T
GND
Ground
Under any condition
Below 1.0
• Inspect for continuity
(Climate control unit—
ground: 1T—GND)
• Inspect center panel
1U
Potentiometer
signal
Air mix actuator
Set temperature at MAX
COLD
0.6
• Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 1U—
C)
• Inspect air mix actuator
• Inspect terminal voltage of
climate control unit (1B)
Set temperature at MAX
HOT
4.3
1V
—
—
—
—
—
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action
U–50
CONTROL SYSTEM
1W
Potentiometer
signal
Airflow mode
actuator
VENT mode
4.3
• Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
1W—C)
• Inspect airflow mode
actuator
• Inspect terminal voltage of
climate control unit (1B)
BI-LEVEL mode
3.3
HEAT mode
2.3
HEAT/DEF mode
1.5
DEFROSTER mode
0.6
1X
Hazard warning
SW signal
Hazard warning
switch
Hazard warning switch is
off
12
• Inspect for continuity or
short circuit (Climate control
unit—flasher unit: 1X—H)
• Inspect flasher unit
Hazard warning switch is
on
Below 1.0
• Inspect terminal voltage of
climate control unit (1T)
• Inspect center panel
2A
Panel light control
signal
Panel light control
switch
Headlight switch ON and
panel light control switch
at max. illumination
0.2
• Inspect for continuity
(Climate control unit— panel
light control switch: 2A—C)
(Panel light control switch—
ground: C—GND)
• Inspect panel light control
switch
Headlight switch ON and
panel light control switch
at min. illumination
10.2
• Inspect for short circuit
(Climate control unit— panel
light control switch: 2A—C)
2B
TNS signal
TNS relay
Headlight switch OFF
Below 1.0
• Inspect for short circuit
(Climate control unit—TNS
relay: 2B—D)
• Inspect TNS relay
• Inspect headlight switch
Headlight switch ON
12
• Inspect for continuity or
short circuit (Climate control
unit—TNS relay: 2B—D)
• Inspect TNS relay
• Inspect headlight switch
2C
Motor drive signal
Air mix actuator
Moving to COLD
12
• Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 2D—
D, 2C—F)
• Inspect air mix actuator
Moving to HOT
Below 1.0
2D
Motor drive signal
Air mix actuator
Moving to HOT
12
• Inspect for continuity or
short circuit (Climate control
unit—air mix actuator: 2C—
F, 2D—D)
• Inspect air mix actuator
Moving to COLD
Below 1.0
2E
Motor drive signal
Airflow mode
actuator
Moving to DEFROSTER
12
• Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
2E—F, 2G—D)
• Inspect airflow mode
actuator
Moving to VENT
Below 1.0
2F
Backup power
supply
ROOM 15 A fuse
Under any condition
B+
• Inspect for continuity or
short circuit (Climate control
unit—fuse: 2F— ROOM 15
A fuse)
• Inspect ROOM 15 A fuse
2G
Motor drive signal
Airflow mode
actuator
Moving to VENT
12
• Inspect for continuity or
short circuit (Climate control
unit—airflow mode actuator:
2G—D, 2E—F)
• Inspect airflow mode
actuator
Moving to DEFROSTER
Below 1.0
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action
CONTROL SYSTEM
U–51
U
End Of Sie
2H
IG2
A/C 15 A fuse
Ignition switch at ON
position
B+
• Inspect for continuity or
short circuit (Climate control
unit—fuse: 2H—A/C 15 A
fuse)
• Inspect A/C 15 A fuse
Ignition switch at LOCK
position
Below 1.0
• Inspect for short circuit
(Climate control unit—fuse:
2H—A/C 15 A fuse)
2I
Motor drive signal
Air intake actuator
Moving to
RECIRCULATE
12
• Inspect for continuity or
short circuit (Climate control
unit—air intake actuator:
2I—F, 2K—D)
• Inspect air intake actuator
Moving to FRESH
Below 1.0
2J
—
—
—
—
—
2K
Motor drive signal
Air intake actuator
Moving to FRESH
12
• Inspect for continuity or
short circuit (Climate control
unit—air intake actuator:
2K—D, 2I—F)
• Inspect air intake actuator
Moving to
RECIRCULATE
Below 1.0
2L
GND
Ground
Under any condition
Below 1.0
• Inspect for continuity
(Climate control unit—
ground: 2L—GND)
Terminal
Signal
Connected to
Test condition
Voltage (V)
Action