CHARGING SYSTEM [L3 WITH TC]

01-17–7

01-17

9. Turn the following electrical loads on and verify that the current reading increases more than the minimum

value indicated below.

— If it is not as specified, go to the PCM and generator shearing inspection. (See 01-17-7 PCM and generator

shearing inspection.)

• Headlights (high-beam)

• Blower motor (HI)

• Rear window defroster

• Brake lights

Generator generated current minimum value

70 % of the nominal output current (nominal output current: 110 A)
[Ambient temp. 20

°C {68 °F}, voltage 13.0— 15.0 V, both engine and generator are hot]

PCM and generator shearing inspection

1. Connect the M-MDS to the DLC-2.

2. Inspect as follows:

DLC-2

acxuuw00002019

Step

Inspection

Action

1

Measure the generator terminal B voltage when the
electrical loads

*1

are on and off.

15 V or more

Go to Step 2.

13— 15 V

Normal

*2

13 V or less

Go to Step 3.

2

Monitor the ALTT V PID using the M-MDS, or measure the
voltage of PCM terminal 2AJ using a tester. Is the voltage
between 13 and 15 V ?

Yes

Go to Step 4.

No

PCM input error.

3

Monitor the ALTT V PID using the M-MDS, or measure the
voltage of PCM terminal 2AJ using a tester. Is the voltage
between 13 and 15 V ?

Yes

Go to Step 5.

No

PCM input error.

4

Monitor the ALTF PID using the M-MDS, or calculate the
duty value of the PCM terminal 2AI using an oscilloscope.
Is the duty value 100 % ?

Yes

PCM input error.

No

PCM, generator, or
both are not
normal.

0V

A

B

B

A

x 100 (%) = DUTY (%)

1871-1U-06B(01-17).fm 7 ページ 2006年3月15日 水曜日 午前10時49分

CHARGING SYSTEM [L3 WITH TC]

01-17–8

*1

: Headlights, blower motor, rear window defroster, and brake lights.

*2

: If the generator field coil duty value does not change when electrical loads (such as headlights, blower motor,

rear window defroster, brake lights) are on or off, inspection with discharged battery is needed.

Generator Inner Parts
Rotor

1. Measure the resistance between the slip rings

using a tester.

• If not within the specification, replace the

rotor.

Generator rotor resistance (between slip

rings) [20

°C {68 °F}]

1.8— 2.2 ohm

2. Verify that there is no continuity between the slip

ring and core using a tester.

• If there is continuity, replace the rotor.

3. Inspect the slip ring surface condition.

• If the slip ring surface is rough, use a lathe or

fine sandpaper to smooth it.

5

Monitor the ALTF PID using the M-MDS, or calculate the
duty value of the PCM terminal 2AI using an oscilloscope.
Is the duty value 0 % ?

Yes

PCM input error.

No

PCM, generator, or
both are not
normal.

Step

Inspection

Action

0V

A

B

B

A

x 100 (%) = DUTY (%)

acxuuw00002021

acxuuw00002022

1871-1U-06B(01-17).fm 8 ページ 2006年3月15日 水曜日 午前10時49分

CHARGING SYSTEM [L3 WITH TC]

01-17–9

01-17

Stator coil

1. Verify that the continuity is as indicated in the

table.

• If there is any malfunction, replace the stator.

2. Verify that there is no continuity between the

stator coil leads and core using a tester.

• If there is continuity, replace the stator coil.

Brush

1. Inspect brushes for wear.

• If any brush is worn almost to or beyond the

limit, replace all of the brushes.

Generator brush length

Standard: 22.5 mm {0.89 in}
Minimum: 5.0 mm {0.20 in}

1

2

3

4

5

6

acxuuw00002023

Terminal

: Continuity

1

2

3

4

5

6

acxuuw00002024

acxuuw00002025

MINIMUM

STANDARD

acxuuw00002026

1871-1U-06B(01-17).fm 9 ページ 2006年3月15日 水曜日 午前10時49分

CHARGING SYSTEM [L3 WITH TC]

01-17–10

Brush spring

1. Measure the force of the brush spring using a spring pressure gauge.
2. Read the spring pressure gauge at the brush tip

projection of 2 mm {0.079 in}.

• Replace the brush spring if necessary.

Generator brush spring force

Standard: 4.1— 5.3 N {0.42— 0.54 kgf, 0.92—

1.19 lbf}

Minimum: 1.7 N {0.17 kgf, 0.38 lbf}

Rectifier (Using an analog circuit tester)

1. Inspect for continuity of the diodes using an

analog circuit tester.

• If not as specified, replace the rectifier.

Specification

Rectifier (Using a digital circuit tester)

1. Inspect for continuity of the diodes using a digital circuit tester.

• If not as specified, replace the rectifier.

Specification

Bearing

1. Inspect for abnormal noise, looseness, and

sticking.

• Replace the bearing if necessary.

End Of Sie

2 mm
{0.079 in}

acxuuw00002027

Negative

Positive

Continuity

E

P1, P2, P3, P4,

P5, P6

Yes

B

No

P1, P2, P3, P4,

P5, P6

E

No

B

Yes

P4

P5

P6

P3

P2

P1

E

B

acxuuw00002028

Negative

Positive

Continuity

E

P1, P2, P3, P4,

P5, P6

No

B

Yes

P1, P2, P3, P4,

P5, P6

E

Yes

B

No

acxuuw00002029

1871-1U-06B(01-17).fm 10 ページ 2006年3月15日 水曜日 午前10時49分

Была ли эта страница вам полезна?
Да!Нет
3 посетителя считают эту страницу полезной.
Большое спасибо!
Ваше мнение очень важно для нас.

Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.

Текст

Политика конфиденциальности