Mazda CX 7. Manual — part 296
CONTROL SYSTEM
07-40–9
07-40
EVAPORATOR TEMPERATURE SENSOR INSPECTION
id074000801200
1. Set the fan speed MAX HI.
2. Set the temperature control at MAX COLD (Turn the left).
3. Turn the A/C switch off.
4. Set the RECIRCULATE mode.
5. Close all doors and windows.
6. Wait for 5 min.
7. Remove the glove compartment. (See 09-17-8 GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
8. Disconnect the evaporator temperature sensor connector.
9. Measure the temperature at the blower inlet.
10. Measure the resistance between terminals of the
evaporator temperature sensor.
• If the resistance is not as shown in the graph,
replace the evaporator temperature sensor.
End Of Sie
WM: AIR INTAKE ACTUATOR
AIR INTAKE ACTUATOR REMOVAL/INSTALLATION
id074000801400
1. Disconnect the negative battery cable.
2. Remove the glove compartment. (See 09-17-8 GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
End Of Sie
16
14
12
10
8
6
4
2
0
-10
{14}
{32}
{50}
{68}
{86}
{104}
{122}
0
TEMPERATURE
KILOHM
RESIST
ANCE
10
20
30
40
50
{ F}
C
acxuuw00000978
1
Air intake actuator connector
2
Air intake actuator
1
2
acxuuw00001566
1871-1U-06B(07-40).fm 9 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–10
AIR INTAKE ACTUATOR INSPECTION
id074000801500
1. Connect battery positive voltage to terminal D or F and ground to terminal F or D of the air intake actuator.
2. Verify that the air intake actuator operates as
shown below.
• If there is any malfunction, replace the air
intake actuator.
End Of Sie
WM: AIRFLOW MODE ACTUATOR
AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION
id074000801600
1. Disconnect the negative battery cable.
2. Remove the glove compartment. (See 09-17-8 GLOVE COMPARTMENT REMOVAL/INSTALLATION.)
3. Remove in the order indicated in the table.
4. Install in the reverse order of removal.
End Of Sie
Connection
Movement
B+
GND
D
F
RECIRCULATE
→ FRESH
F
D
FRESH
→ RECIRCULATE
30
°
90
°
FRESH
RECIRCULATE
D
F
*
*
*
*
acxuuw00001168
F
D
M
acxuuw00002306
1
Airflow mode actuator connector
2
Airflow mode actuator
1
2
acxuuw00001568
1871-1U-06B(07-40).fm 10 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–11
07-40
AIRFLOW MODE ACTUATOR INSPECTION
id074000801700
Caution
• If the lever position exceeds the operation range shown in the figure, the circuit in the actuator
could be damaged. Always perform an actuator operation inspection with the lever movement
within the range shown in the figure.
1. Connect battery positive voltage to terminal D or F and ground to terminal F or D of the airflow mode actuator.
2. Verify that the airflow mode actuator operates as
shown below.
• If there is any malfunction, replace the airflow
mode actuator.
3. Verify that the resistance between the terminals of
the airflow mode actuator is as shown in the
graph.
• If there is any malfunction, replace the airflow
mode actuator.
End Of Sie
WM: CLIMATE CONTROL UNIT
CLIMATE CONTROL UNIT DISASSEMBLY/ASSEMBLY
id074000802000
Full-auto Air Conditioner
Disassemble in the order indicated in the table.
Connection
Movement
B+
GND
D
F
DEFROSTER
→ VENT
F
D
VENT
→ DEFROSTER
VENT
DEFROSTER
F
D C B A
*
18.5
°
71.5
°
acxuuw00000725
M
F
D
B
C
A
VENT
DEFROSTER
acxuuw00000726
RESIST
ANCE
0.5
3.5
KILOHM
BETWEEN B
AND C
TERMINALS WIRE
BETWEEN C
AND A
TERMINALS WIRE
VENT
VENT
DEFROSTER
DEFROSTER
AIRFLOW MODE ACTUATOR POSITION
acxuuw00000727
1
Illumination bulb
2
Body
2
1
FULL-AUTO AIR CONDITIONER
REMOVAL
INSTALLATION
acxuuw00001839
1871-1U-06B(07-40).fm 11 ページ 2006年3月16日 木曜日 午後4時1分
CONTROL SYSTEM
07-40–12
Manual Air Conditioner
Disassemble in the order indicated in the table.
Wire Disassembly Note
1. Disassemble the wire in the shown in the figure.
Wire Assembly Note
1. Assemble the wire to the position as shown in the
figure.
End Of Sie
CLIMATE CONTROL UNIT WIRE ADJUSTMENT
id074000802100
Air Mix Wire
1. Set the temperature control dial to max cold.
2. Set the air mix link to max cold in the direction
shown by the arrow and insert a screwdriver at
the set hole.
3. Connect the air mix wire to the air mix link.
4. Clamp the air mix wire to the wire clamp.
5. Verify that the temperature control dial rotates at
full stroke.
End Of Sie
SOKYU_WM: CLIMATE CONTROL UNIT
1
Knob
2
Air mix wire
(See 07-40-12 Wire Disassembly Note.)
(See 07-40-12 Wire Assembly Note.)
3
Airflow volume control dial
4
Illumination bulb
5
Body
1
4
4
3
2
5
MANUAL AIR CONDITIONER
acxuuw00000732
WIRE
CLIMATE CONTROL
UNIT
1
2
1
acxuuw00000733
AIR MIX WIRE
acxuuw00000734
MAX COLD
TEMPERATURE
CONTROL DIAL
MAX COLD
SET HOLE