Mazda CX-9 Grand Touring. Manual — part 533
DIAGNOSTIC PROCEDURE
DTC B1311 - DIAGNOSTIC PROCEDURE
POSSIBLE CAUSE
door latch and lock actuator (passenger-side) terminal 2A
Open circuit in wiring harness between PLG control module terminal 3C and front
door latch and lock actuator (passenger-side) terminal 2B
Open circuit in wiring harness between front door latch and lock actuator
(passenger-side) terminal 2B and body GND
Door lock-link switch front door latch and lock actuator (passenger-side)
malfunction
PLG control module malfunction
STEP
INSPECTION
ACTION
1
INSPECT DOOR LOCK-LINK SWITCH
Disconnect the door lock-link switch
(Passenger side) connector.
Inspect the door lock-link switch
(Passenger side).
Yes Go to the next step.
No
Replace the front door latch and lock actuator.
(See FRONT DOOR LATCH AND LOCK
ACTUATOR
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 8
© 2005 Mitchell Repair Information Company, LLC.
DTC B1318 [POWER LIFTGATE (PLG) SYSTEM]
DTC B1318 - DETECTION CONDITION POSSIBLE CAUSE CHART
(See FRONT DOOR LATCH AND
LOCK ACTUATOR INSPECTION .)
Is the door lock-link switch normal?
REMOVAL/INSTALLATION .)
Go to Step 3.
2
INSPECT THE FOLLOWING WIRING
HARNESSES
Disconnect the PLG control module
connector.
Disconnect the door lock-link switch
(Passenger side) connector.
Inspect the wiring harness between PLG
control module terminal 3N and front
door latch and lock actuator terminal 2A
for an open circuit.
Inspect the wiring harness between PLG
control module terminal 3C and front
door latch and lock actuator terminal 2B
for an open circuit.
Inspect the wiring harness between front
door latch and lock actuator terminal 2E
and body ground for an open circuit.
Are the wiring harnesses normal?
Yes Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.
3
VERIFY CORRECTION COMPLETED
Reconnect the disconnected connector.
Clear the DTC.
Is DTC B1311 displayed after 10 s or
more have elapsed.
Yes
Replace the PLG control module.
(See POWER LIFTGATE (PLG)
CONTROL MODULE
REMOVAL/INSTALLATION .)
No
DTC troubleshooting completed.
DTC B1318
Power supply voltage decreases
DETECTION
CONDITION
Input voltage from the battery is excessively low (below 10.5 V)
POSSIBLE CAUSE
PLG 20 A fuse malfunction
Open or short circuit in wiring harness between PLG control module terminal
1C and battery
Battery malfunction
Generator malfunction
PLG control module malfunction
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 9
© 2005 Mitchell Repair Information Company, LLC.
DIAGNOSTIC PROCEDURE
DTC B1318 - DIAGNOSTIC PROCEDURE
STEP
INSPECTION
ACTION
1
INSPECT BATTERY VOLTAGE
Inspect the battery voltage.
(See BATTERY INSPECTION [MZI-
3.7] .)
Is the battery voltage normal?
Yes Go to the next step.
No
Recharge or replace the battery.
Go to Step 4.
2
INSPECT FOR PCM DTCs
Connect the M-MDS to the DLC-2.
Are any DTCs for the PCM displayed?
Yes
Perform troubleshooting according to the
corresponding DTC inspection.
Go to Step 4.
No
Go to the next step.
INSPECT THE FOLLOWING WIRING
HARNESSES
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 10
© 2005 Mitchell Repair Information Company, LLC.
DTC B1342 [POWER LIFTGATE (PLG) SYSTEM]
DTC B1342 - DETECTION CONDITION POSSIBLE CAUSE CHART
DIAGNOSTIC PROCEDURE
DTC B1342 - DIAGNOSTIC PROCEDURE
DTC B241A [POWER LIFTGATE (PLG) SYSTEM]
DTC B241A - DETECTION CONDITION POSSIBLE CAUSE CHART
3
Disconnect the negative battery cable.
Disconnect the positive battery cable.
Disconnect the PLG control module
connector.
Inspect the wiring harness between PLG
control module terminal 1C (wiring
harness-side) and positive battery terminal
(wiring harness-side) for an open
circuit/short circuit to ground system.
Is the wiring harness normal?
Yes
Repair or replace the wiring harness.
Go to the next step.
No
Go to the next step.
4
VERIFY CORRECTION COMPLETED
Reconnect the disconnected connector.
Clear the DTC.
Operate the PLG system.
Is DTC B1318 stored?
Yes
Replace the PLG control module.
(See POWER LIFTGATE (PLG)
CONTROL MODULE
REMOVAL/INSTALLATION .)
No
DTC troubleshooting completed.
DTC B1342
PLG control module internal malfunction
DETECTION CONDITION Malfunction in the PLG control module internal circuit
POSSIBLE CAUSE
Malfunction in the PLG control module internal circuit
STEP
INSPECTION
ACTION
1
VERIFY DTC
Clear the DTC.
Operate the PLG
system.
Is DTC B1342
stored?
Yes
Replace the PLG control module.
(See POWER LIFTGATE (PLG) CONTROL MODULE
REMOVAL/INSTALLATION .)
No
DTC troubleshooting completed.
DTC B241A
Touch sensor circuit malfunction
DETECTION
A short circuit to ground in the PLG touch sensor (RH/LH) continues for 5 min or
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 11
© 2005 Mitchell Repair Information Company, LLC.