Mazda X-5. Manual — part 40
CONTROL SYSTEM
01–40–33
01–40
A/C CUT-OFF CONTROL OUTLINE [LF]
E5U014000000N43
• Through energization and non-energization to the A/C relay (magnetic clutch) according to engine operation
conditions, acceleration performance and engine reliability have been improved.
End Of Sie
A/C CUT-OFF CONTROL BLOCK DIAGRAM [LF]
E5U014000000N44
End Of Sie
A/C CUT-OFF CONTROL OPERATION [LF]
E5U014000000N45
• The PCM stops energization to the A/C relay when any of the following conditions are met:
A/C cut-off control operation conditions
End Of Sie
TR SWITCH (AT)
ECT SENSOR
CKP SENSOR
NEUTRAL SWITCH (MT)
CPP SWITCH (MT)
A/C RELAY
PCM
TP SENSOR NO.1, NO.2
APP SENSOR NO.1, NO.2
A/C AMPLIFER
REFRIGERANT PRESSURE
SWITCH (HIGH, LOW)
E5U140ZT5009
Operation condition
A/C relay non-energization period
Purpose
At engine start
Approx. 4 s
Improved startability
At drive-away
Approx. 3 s
Improved drive-away
performance
During acceleration (throttle valve opening angle 50%
or more)
Approx. 5 s
Improved acceleration
performance
When the engine coolant temperature is 113
°C {235
°F}
Repeatedly turns on and off every 10 s
until the engine coolant temperature is
less than approx. 110
°C {230 °F}
Improved engine reliability
When the engine coolant temperature is 118
°C {245
°F} or more
Until the engine coolant temperature
decreases to less than approx. 114
°C
{237
°F}
Improved engine reliability
At high engine speed (engine speed 6,600 rpm or
more)
Approx. 1 s
Improved engine speed
stability
CONTROL SYSTEM
01–40–34
ELECTRICAL FAN CONTROL OUTLINE [LF]
E5U014000000N46
• Through cooling of the radiator and condenser by operation of the cooling fan according to vehicle conditions,
engine reliability and cooling performance have been improved.
• The electrical fan control includes the regular-driving cooling function and the after-cooling function.
• The regular-driving cooling function operates according to the engine conditions during the engine operation.
• The after-cooling function operates when the vehicle has stopped at high engine temperature (ignition switch
off).
• After the ignition switch is turned off, a main relay on request is sent to operate the after-cooling function. (See
01–40–11 MAIN RELAY CONTROL OPERATION [LF].)
End Of Sie
ELECTRICAL FAN CONTROL BLOCK DIAGRAM [LF]
E5U014000000N47
• The PCM determines the engine operation conditions based on input signals from the sensors, and sends a
signal to the cooling fan relay No.1, No.2, No.3.
End Of Sie
ELECTRICAL FAN CONTROL OPERATION [LF]
E5U014000000N48
• When the operation conditions are met for each function, the PCM sends an operation signal to cooling fan
relay No.1 or No.2/No.3 to operate the cooling fan motors.
• The rotation speed of the cooling fan motor is switched between three levels according to a combination of the
cooling fan relays.
• The cooling fan motor operation switches in the order of stop, low speed, middle speed, and high speed, taking
3 s for each operation while regular-driving cooling.
ECT SENSOR
VEHICLE SPEED SIGNAL
IGNITION SWITCH
COOLING FAN RELAY NO.2
PCM
TP SENSOR NO.1, NO.2
COOLING FAN RELAY NO.3
COOLING FAN RELAY NO.1
IAT SENSOR
REFRIGERANT PRESSURE
SWITCH (MIDDLE)
A/C AMPLIFER
REFRIGERANT PRESSURE
SWITCH (HIGH, LOW)
E5U140ZT5010
CONTROL SYSTEM
01–40–35
01–40
Operation Conditions
End Of Sie
Function
Operation condition
Cooling fan
motor rotation
speed
Cooling fan relay
ECT
A/C
amplifier
(A/C switch)
Refrigerant
pressure
switch
(high, low)
Vehicle speed
No.1
No.2
No.3
Regular-
driving cooling
Less than 100
°C
{212
°F}
OFF
—
Stop
OFF
ON
OFF
More than 70
km/h {44 mph}
45 —70 km/h
{28—43 mph}
Low
ON
OFF
OFF
Less than 45
km/h {27 mph}
Middle
ON
OFF
ON
ON
—
High
ON
100—108
°C
{213—226.4
°F}
OFF
—
Middle
ON
OFF
ON
ON
High
ON
More than 108
°C
{227
°F}
—
After-cooling
• When all the following conditions are met:
— Ignition switch: OFF
— Estimated maximum engine coolant temperature is high after
engine stop
Low
ON
OFF
OFF
• When all the following conditions are met:
— Estimated maximum engine coolant temperature is the
specified value or more even when operating at low rotation
speed.
Middle
ON
OFF
ON
COOLING
FAN RELAY
NO.1
COOLING
FAN RELAY
NO.3
COOLING
FAN RELAY
NO.2
TO PCM
TO PCM
TO PCM
B+
E5U140ZN5855
CONTROL SYSTEM
01–40–36
STARTER CUT-OFF CONTROL OUTLINE [LF]
E5U014000000N49
• Theft deterrence has been improved by controlling energization to the starter relay according to an engine stop
request signal from the immobilizer system.
End Of Sie
STARTER CUT-OFF CONTROL BLOCK DIAGRAM [LF]
E5U014000000N50
End Of Sie
STARTER CUT-OFF CONTROL OPERATION [LF]
E5U014000000N51
• The PCM stops energization of the starter relay according to an engine stop request from the immobilizer
system.
When receiving engine stop request signal
— The PCM does not establish a ground to the starter circuit. Therefore, the starter motor does not rotate
because there is no energization of the starter relay even if the ignition switch is turned to the START
position, and the engine does not start.
When not receiving engine stop request signal
— The PCM establishes a ground to the starter circuit. Therefore, when the ignition switch is turned to the
START position, the starter relay is energized and the starter motor rotates. As a result, the engine starts
normally.
End Of Sie
INSTRUMENT CLUSTER
(IMMOBILIZER RELATED
INFORMATION)
STARTER RELAY
PCM
E5U140ZW5403
PCM
M
WHEN NOT RECEIVING ENGINE
STOP REQUEST SIGNAL
WHEN ENGINE STOP REQUEST
SIGNAL IS RECEIVED
IGNITION
SWITCH
START
SIGNAL
STARTER
RELAY
STARTER
AT
TR SWITCH
STARTER
SWITCH
MT
IG 1
B+
PCM
M
IGNITION
SWITCH
START
SIGNAL
STARTER
RELAY
STARTER
AT
TR SWITCH
STARTER
SWITCH
MT
IG 1
B+
E5U140ZT5200
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.